Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Pre-Solicitation opportunity from Department Of Veterans Affairs was posted on November 17, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Z1DA--508-21-109 - Construct Wastewater Metering Station

Closed
36C24722R0010Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541330
New
SLED
2026 AC Water Main Replacement
Solicitation # 2026-RFQ-042
Solicitation 2026-RFQ-042 is a request for qualifications from the City of Mercer Island Public Works department for professional engineering services to design water system upgrades. The project focuses on replacing approximately 5,000 linear feet of aging asbestos cement water mains with ductile iron mains along SE 40th St and E Mercer Way. The scope is divided into two phases: Phase 1 involves water system and PRV vault replacement on SE 40th St from Greenbrier Ln to 97th Ave SE, and Phase 2 extends the replacement to 97th Ave SE and the 3700 and 3800 blocks of East Mercer Way. Additional components for replacement include fire hydrants and water services. The design must comply with the Reduction of Lead in Drinking Water Act and the City of Mercer Island Standard Details Water. The project follows a goal-based timeline with bid-ready plans for Phase 1 due by Q2 2027 and Phase 2 by Q3 2027, with overall construction completion targeted for Q2 2028. Qualified firms must be licensed in the State of Washington and submit a Statement of Qualifications limited to 12 pages, including a proposed timeline and three references from the last five years. Selection is at the sole discretion of the City, and the awarded firm will negotiate a scope and fee schedule using the City's standard professional services agreement. Administration is managed by the City Manager, with payments issued via City warrant within 45 days of receiving a proper monthly invoice.
Public Works

POSTED

about 11 hours ago

DEADLINE

in 14 days

General Info

NAICS

541330 - Engineering Services

Place of Performance

Decatur, GA 30030, GA

Set-Aside

NONE

Documents

2

36C24722R0010+-+Request+For+330s.docx

DOCX

508-21-109+A-E+SOW+%286%29.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Presolicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 247-NETWORK Contract Office 7 (36C247)
Contacts1 person available
OfficeAUGUSTA, GA, 30904, USA
Office AddressAUGUSTA, GA, 30904, USA
Contacts
Evonne HugginsContracting Officer

Full Description

Show more
This request and procurement is 100% restricted to Service-Disabled, Veteran-Owned Small Businesses (SDVOSB) THIS IS NOT A REQUEST FOR PROPOSAL. THIS IS A REQUEST FOR SF 330'S ARCHITECT/ENGINEER QUALIFICATION PACKAGES ONLY. ALL INFORMATION NEEDED TO SUBMIT SF 330 DOCUMENTS IS CONTAINED HEREIN. NO SOLICITATION PACKAGE WILL BE ISSUED IN THIS PHASE. THERE WILL BE NO SITE VISITS ARRANGED DURING THIS PHASE OF THE REQUIREMENT. THIS PROJECT IS SUBJECT TO AVAILABILITY OF FUNDS. The Government will not pay, nor reimburse, any costs associated with responding to this request. The Government is under no obligation to award a contract as a result of this announcement. Federal Acquisitions Regulation (FAR) 36.6 selection procedures apply. Firms that design or prepare specifications in conjunction with this contract are prohibited from participating on any future contracts based on those documents. ---------- GENERAL INFORMATION: The Department of Veterans Affairs, Atlanta VA Healthcare System located at 1670 Clairmont Road Decatur, GA 30033 is seeking sources and intends to award a firm fixed-price contract for Architect/Engineering (A/E) services for the development of complete construction documents, which include working drawings, specifications, reports, and construction period services, for Project 508-21-109 Construct Wastewater Metering Station . The A/E Services listed herein is being procured in accordance with the Federal Acquisition Regulation (FAR) 36.6 and VAAR 836.6. All submissions will be evaluated in accordance with the evaluation selection criteria as specified herein. The resultant contract will include FAR CLAUSE 52.223-99 and VHA Supplemental Contract Requirements to implement Executive Order 14042, Ensuring Adequate COVID Safety Protocols for Federal Contractors, dated September 9, 2021 (published in the Federal Register on September 14, 2021, 86 FR 50985). Point of Contact: Evonne Huggins, Contracting Officer Email: Evonne.Huggins@va.gov PROJECT INFORMATION The NAICS Code for this procurement is 541330 Engineering Services and the annual small business size standard is $16.5M. The projected award date for the anticipated A/E contract is on or before 30 September 2022. The anticipated period of performance for completion of design is 126 calendar days after Notice to Proceed. The NAICS code for the anticipated Construction project is projected to be 236220 and magnitude of construction is predicted to be between $100,000 and $250,000.The anticipated award date of the construction phase of the project is projected to be by 30 September 2022. An Architect & Engineer (A/E) contract will be negotiated for the development of complete construction documents which include working drawings, specifications, reports, and construction period services. The A/E will be given written information; participate in project planning meetings, pre-proposal meeting, and pre-construction meeting as required; communicate with VA personnel via telephone or e-mail; and is expected to coordinate so that the final documents include all requirements in accordance with industry standard practices, VA standards, VA design manuals, and review comments. STATEMENT OF TASK/SCOPE OF WORK SEE SCOPE OF WORK ATTACHED A/E SELECTION PROCESS: Responsive firms submitting SF 330 s in response to this announcement, not later than the closing date and time specified herein and in accordance with submission requirements, will be considered for initial selection evaluation. Following initial evaluation, no less than three firms that are selected as the most highly qualified based on the selection criteria responses, will be selected for interviews. Selected firms will be notified by telephone or email of selection and provided further instructions. Evaluating past performance and experience may include information provided by the firm, customer inquiries, Government databases, and publicly available sources. Failure to provide requested data, accessible points of contact or valid phone numbers could result in a firm being considered less qualified. All projects provided in the SF330 must be completed by the office/branch/individual team member performing the work under this contract. SELECTION CRITERIA: Evaluation and selection of firms will be based on submissions and direct responses to the following criteria which are numbered in descending order of importance: 1) Professional qualifications necessary for satisfactory performance of required service and working together as a team (in-house and/or consultants(s)). Provide brief resumes of proposed team members who will specifically serve as the Project Managers and Designers of Record. The Designers of Record shall perform and direct the design within their respective discipline and shall sign and seal the drawings. All Designers of Record must be professionally registered in their discipline. Each resume shall include a minimum of two (2) specific completed projects that best illustrate the individual team members experience relevant to this contract scope. 2) Specialized experience and technical competence in the type of work required, including, where appropriate on similar projects: experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials (include Government and private experience). Technical competence includes design quality management procedures, CADD, equipment resources, and laboratory requirements of the prime firm and any subcontractors. In addition, provide information on the effectiveness of the proposed project team (including management structure; coordination of disciplines, offices and/or subcontractors; and prior working relationships). 3) Capacity to accomplish work in the required time. This factor evaluates firm's experience with similar size projects and the available capacity of key disciplines when evaluating the capacity of a firm to perform the work in the required time. The general workload and staffing capacity of the design office will be evaluated. List current projects with similar design fee being designed in the firms office. Indicate the firms present workload and the availability of the project team (including sub-consultants) for the specified contract performance period; Describe experience in successfully delivering projects per performance schedule, providing timely construction support, and successfully completing multiple projects with similar delivery dates 4) Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules. VISN 7 will evaluate past performance on recent and relevant contracts with government agencies (emphasis on VA work) and private industry in terms of cost control, quality of work, compliance with performance schedules and a record of significant claims against the firm due to improper or incomplete engineering services (references required). Recent is defined as performance occurring within 5 years of the date of this notice, except that ongoing projects must have begun no less than one (1) year prior to the issuance of this notice. Relevancy is defined as performance of work on projects that are similar in scope to the types of projects anticipated under the resultant contracts. Respondents with no previous past performance shall state this when addressing the selection criteria. Where there is no record of past performance, the proposal will be evaluated neither favorably nor unfavorably. Superior performance ratings on relevant projects may be considered more favorably in the evaluation. Submission Requirements: Submit a maximum of four (4) references; any of the following evaluations are acceptable: A-E Contractor Appraisal Support System (ACASS), Contractor Performance Assessment Report System (CPARS), or Past Performance Questionnaire (PPQ) evaluation for each project submitted under Criterion 2. If a completed CPARS evaluation is available, it shall be submitted with the completed SF330 package. If there is not a completed ACASS/CPARS evaluation, the PPQ included with this notice is provided for the Offeror or its team members to submit for each project included in criterion (2). If a PPQ is submitted, but an official ACASS/CPARS evaluation is found for that project in government databases, the official evaluation will take precedence. If an ACASS/CPARS evaluation is not available, ensure correct phone numbers and email addresses are provided for each contract customer/reference. Completed PPQs should be submitted with your SF330. A-Es should follow-up with references to ensure timely submittal of questionnaires. At the reference s request, questionnaires may be submitted directly to the Contracting Officer Evonne Huggins via email at Evonne.Huggins@va.gov , prior to the response date. A-Es shall not incorporate by references into their response ACASS/CPARS or PPQ evaluations previously submitted in response to other A-E services procurements. However, this does not preclude the Government from utilizing previously submitted PPQ information in the past performance evaluation. Submitted ACASS/CPARS and PPQ evaluations will not be counted as part of the 50-page limitation and shall be attached to the SF330, behind the SF330 Part II document 5) Location in general geographical area of the project and knowledge of the locality of the project; The area of consideration for offeror is a 400-mile driving radius between offeror location and the VA Medical Center referenced in paragraph 1 General Information. (Determination of mileage eligibility will be based on www.google.com) PER VAAR 836.602-1 6) The extent to which potential contractors identify and commit to the use of service-disabled Veteran-owned small businesses, Veteran-owned small businesses, and other types of small businesses as subcontractors. 7) Experience in construction period services to include professional field inspections during the construction period, review of construction submittals, support in answering requests for information during the construction period, and support of construction contract changes to include drafting statements of work, and cost estimates shall be included as an evaluation criterion when construction period services is included in the statement of work for A-E services. SUBMISSION CRITERIA/REQUIREMENTS: Interested firms having the capabilities to perform this work must submit ONE (1) ELECTRONIC SF 330, including Parts I and II, and attachments (if any) by email to Evonne.Huggins@va.gov no later than the date and time specified. Interested firms are responsible for ensuring electronic delivery of submission by the time and the date specified. It is highly recommended interested firms confirm electronic submissions have been received by the Contracting Officer. Size limits of e-mails are restricted to 5MB. If more than one email is sent, please number emails in Subjects as 1 of n and include the notice number, project number and title in the email subject line. (Example: SF330 Submission, # 36C24719R0014 Project 508-19-106 Correct Main Tower Window Deficiencies Bldg. 1 (1 of n, 2 of n, etc.). All SF 330 submissions must include the following information either on the SF 330 or by accompanying document: 1) Cage Code 2) Dun & Bradstreet Number 3) Tax ID Number 4) The E-mail address and Phone number of the Primary Point of Contact 5) A copy of the firms VetBiz Registry 6) SF 330 MUST INDICATE THE PERCENTAGE of the contract performance cost that will be expended by the prime firm s employees and in which discipline(s) and subcontracted percentage of contract performance cost to be expended (and in what disciplines). Any subcontracted or otherwise business entity must be identified by name, office location and size/type of business (i.e. SDVOSB, VOSB, 8(a), large, etc.). This is in order to assure compliance with FAR Clause 52.219-14(b)(1) Limitations on Subcontracting. Failure to provide this information may deem the firm as nonresponsive and preclude further consideration. 7) Past Performance References REQUESTS FOR INFORMATON ON THIS PRESOLICITATION NOTICE: All RFIs shall be submitted to Evonne.Huggins@va.gov. The firm and or AE on staff representing the project must follow all local State laws and guidelines for which the medical center is located. NOTE: In order for a Service-Disabled Veteran Owned Small Business (SDVOSB) to be considered as a proposed contractor, the firm must be verified and visible by VETbiz (www.vetbiz.gov) and registered in the System For Award Management (SAM) database (www.sam.gov) at time of submission of their qualifications AND at time of award. Failure of a proposed SDVOSB to be verified by the CVE at the time the SF 330 is submitted shall result in elimination from consideration as a proposed contractor. All Joint Ventures must be CVE verified at time of submission and submit agreements that comply with 13CFR 125.15 prior to contract award. Each respondent must be able to demonstrate the ability to comply with FAR Clause 52.219-14, Limitations on Subcontracting. Electronic submittals received after the date and time specified will not be considered. Late proposal rules per FAR 15.208 will be followed for late submittals. Firms not providing the required information may not be considered. All information must be included in the SF330 submission package. It is the offeror s responsibility to check the Federal Business Opportunities website at: www.fbo.gov for any revisions to this announcement prior to submission of SF330s.

More opportunities from Department Of Veterans Affairs → 247-NETWORK Contract Office 7 (36C247)

Same awarding agency

NAICS: 811210
New
Federal
J065-- Carestream Portable X-ray Service Base plus Four
Solicitation # 36C24727Q0063
The Department of Veterans Affairs, Network Contracting Office 7, is conducting market research through a Sources Sought Notice to identify authorized businesses capable of providing maintenance and repair services for Carestream portable X-ray equipment at the Birmingham VA Medical Center. The requirement specifically covers two Carestream DRX Revolution mobile X-ray systems and two Carestream LUX 35 mobile detectors. The scope of work includes preventive maintenance, troubleshooting, corrective repairs, parts, labor, and calibration, with the explicit requirement that Carestream performs the actual services. The anticipated period of performance consists of a base year running from December 12, 2026, to December 11, 2027, with four subsequent one-year option periods extending through December 11, 2031. Interested respondents must provide a capability statement including company identification, UEI, CAGE code, and business size under NAICS 811210. A critical requirement is the submission of a current authorization letter on Carestream letterhead confirming the respondent's ability to provide these services. The government is particularly interested in SBA-certified Service-Disabled Veteran-Owned Small Businesses and Veteran-Owned Small Businesses to determine the final acquisition strategy. Technical requirements include compliance with NFPA-99, OSHA, CDRH, JCAHO, and FDA standards, as well as the use of calibrated test equipment. Contractors must also maintain bodily injury liability insurance of at least 500,000 dollars per occurrence and adhere to strict security requirements for unclassified information technology resources. Capability statements are due by October 26, 2026.
Electronic and Precision Equipment Repair and Maintenance

POSTED

about 14 hours ago

DEADLINE

in 6 days
View Details
NAICS: 811310
New
Federal
H930--Generator Preventative Maintenance
Solicitation # 36C24727Q00380001_1
The Department of Veterans Affairs, through the VISN 7 Network Contracting Office, is soliciting a contract for preventive maintenance inspection and servicing of twelve emergency generator units at the Carl Vinson VA Medical Center in Dublin, Georgia. This is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSBs). The scope of work requires the contractor to provide all labor, tools, equipment, and materials, including lubricants, coolants, filters, and gaskets. Maintenance is divided into two levels: Service Level I, performed semiannually, and Service Level II, performed annually. Level II service must include annual load bank testing for each generator, consisting of a four-hour step-loading process. All work must meet or exceed NFPA 110 standards and comply with the facility's Vendor Control for Equipment Maintenance memorandum. The contract structure consists of a one-year base period with four subsequent twelve-month option years. Award will be granted to a responsible SDVOSB offeror based on the most advantageous offer, considering the lowest price, demonstrated technical capability, and a satisfactory past performance record with at least one relevant reference. Technical proposals must provide a detailed demonstration of understanding the Statement of Work rather than simply paraphrasing the requirements. Payments will be made semi-annually in arrears via Electronic Funds Transfer. The contractor is also required to provide Safety Data Sheets for all chemicals used and must adhere to strict subcontracting limitations, ensuring no more than 50 percent of the government-paid amount is paid to firms that are not certified SDVOSBs or VOSBs.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

1 day ago

DEADLINE

in 3 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS