Z1DA--Upgrade Fire Alarm System Construction 676-22-110
Open
36C25226B0014-1Federal
Response Deadline
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
Show more
The Department of Veterans Affairs is soliciting bids for Project 676-22-110 to upgrade the fire alarm system at the Tomah VA Medical Center in Tomah, Wisconsin. This project is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS 238210, with an estimated project magnitude between $5 million and $10 million. The scope of work includes the demolition and removal of existing fire alarm devices and the installation of a new system, with a performance period of 460 calendar days following the Notice to Proceed. The contract is a firm-fixed-price agreement and is subject to the Davis-Bacon Act and union prevailing wage rates.
Bids are due via email to the Contracting Officer by 10:00 AM local time on December 1, 2026, with a public virtual bid opening held via Microsoft Teams at 11:30 AM that same day. Submissions must include a completed Standard Form 1442 and a bid guarantee on form SF24 for at least 20 percent of the bid price, not to exceed $3 million. Key personnel requirements include a CQC System Manager and a Site Safety and Health Officer (SSHO) with specific certification and experience levels. The project involves strict infection control risk assessments (ICRA) and requires the contractor to provide a security system operational test plan and comprehensive system documentation.
General Info
SDVOSB bid for Tomah VA Medical Center fire alarm upgrade, $5-10 million.
PDF, High priority: read this first2 pages · amendment
HighAI Summary for 36C25226B0014 Amendment 0002 - Upgrade Fire Alarm System: Amendment A0002 to solicitation 36C25226B0014 for the Upgrade Fire Alarm System project at Tomah VA Medical Center. This amendment extends the bid submission deadline to October 20, 2026, at 10:00 AM CDT. It also provides instructions for a virtual public bid opening via Microsoft Teams and specifies that bids must be submitted via email to the Contracting Officers.
DOCX
DOCX, High priority: read this first3 pages · amendment
HighAI Summary for 36C25226B0014 Amendment A0001: Amendment A0001 to solicitation 36C25226B0014 issued by the Department of Veterans Affairs / Great Lakes Acquisition Center. Dated 08-13-2026, it publishes pre-bid site visit sign-in sheets, responses to RFIs, an infection control list, and low/medium/high risk location information for the upgrade fire alarm project. It also provides virtual bid opening instructions, email submission requirements, and clarifies that bids are due September 22nd at 10:00 AM local time, with the public virtual bid opening at 11:30 AM.
DOCX
DOCX, High priority: read this first3 pages · amendment
HighAI Summary for Amendment A0003 to Solicitation 36C25226B0014: Standard Form 30 Amendment A0003 for solicitation 36C25226B0014 issued by the Department of Veterans Affairs. This amendment extends the offer receipt deadline to November 4, 2026, at 10:00 CST. Key changes include extending the preconstruction submission period from 20 to 60 days, updating the construction period of performance chart, and providing virtual bid opening instructions via Microsoft Teams. The amendment also incorporates Addendum No. 1 and responses to RFIs.
DOCX
DOCX, High priority: read this first3 pages · amendment
HighAI Summary for Amendment A0004 to Solicitation 36C25226B0014: Standard Form 30 Amendment A0004 for solicitation 36C25226B0014 issued by the Department of Veterans Affairs. This amendment extends the offer receipt deadline to December 1, 2026, at 10:00 AM CST and provides instructions for a virtual public bid opening via Microsoft Teams.
DOCX
DOCX, High priority: read this first3 pages · amendment
HighAI Summary for Amendment A0005 - Solicitation 36C25226B0014: Amendment A0005 to solicitation 36C25226B0014 issued by the Department of Veterans Affairs. This amendment publishes responses to RFIs, provides contact information for the BAS Contractor (Johnson Controls), and includes Addendum Number 2. It also specifies virtual bid opening details via Microsoft Teams and confirms the bid submission deadline of December 1st at 10:00 AM local time.
DOCX
DOCX, High priority: read this first2 pages · amendment
HighAI Summary for Amendment A0006 - Solicitation 36C25226B0014: Amendment A0006 to solicitation 36C25226B0014 issued by the Department of Veterans Affairs. This amendment provides a response to an RFI regarding Intelligent Device Protocol (IDP) specifications, establishes virtual bid opening procedures via Microsoft Teams, and sets the bid submission deadline for December 1st at 10:00 AM local time.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for Infection Control 676-22-110 Upgrade Fire Alarm: Infection Control document for project 676-22-110, Upgrade Fire Alarm. It lists building areas, floor locations, ICRA levels, mobile ICRA cart approval, and infection control comments for numerous spaces. The content appears to function as an infection control/specification matrix and includes repeated instructions such as venting outdoors or to a low-risk adjacent space with a particle counter. Key project-specific requirements are provided across multiple pages, with some OCR corruption and incomplete rows.
PDF
PDF, High priority: read this first9 pages · amendment
HighAI Summary for RFI Response Amendment A0003: RFI question-and-comment responses for Project 676-22-110 Upgrade Fire Alarm System under Solicitation 36C252-26-B-0014. The document is labeled Amendment A0003 (Oct. 6, 2026) and addresses pre-bid RFIs concerning SSHO and CQC qualifications, government delay and suspension handling, infection control class requirements, bid alternates, Division 27/28 scope, fire watch, DDC panels, tramway devices, and fire dampers.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for S02 - Bid Specifications for Upgrade Fire Alarm System, Project 676-22-110: This document contains the final bid specifications for the Upgrade Fire Alarm System project (No. 676-22-110) at the Tomah VA Medical Center, Tomah, Wisconsin. Dated April 21, 2026, it includes detailed divisions and sections covering general requirements, quality control, demolition, fire alarm system components, electrical and communications systems, and related construction specifications. The document serves as a comprehensive guide for contractors submitting bids, outlining technical requirements, project scope, and drawing sheets necessary for the project execution.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for S02 Part 3 Fire Alarm Demolition Plans 20260421: This document titled 'S02 Part 3 Fire Alarm Demolition Plans' dated 2026-04-21 contains detailed general notes and keyed notes related to the demolition and removal of existing fire alarm devices and systems. It includes instructions for protecting existing equipment, maintaining utility services, and coordinating with other construction elements to ensure a fully functional fire alarm system. The document emphasizes continuous building occupancy and system availability during work, as well as contractor responsibilities for moving furniture and cleaning. It references additional sheets for legends, notes, and access panel locations, indicating its role as a technical specification for fire alarm system demolition work.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for S02 - PART 6 - Fire Alarm New Plans 20260421: This document titled 'S02 - PART 6 - Fire Alarm New Plans 20260421' appears to be a set of technical specifications or plans related to fire alarm systems. The content includes references to construction elements such as roadways, residential complexes, walls, and various building components, indicating detailed construction or installation plans. The version or date indicated is 20260421, suggesting a planned or issued date of April 21, 2026. The document likely serves as a critical technical reference for procurement or construction related to fire alarm system installation in new building projects.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for S02 - PART 7 - FIRE ALARM NEW PLANS 20260421: This document titled 'S02 - PART 7 - FIRE ALARM NEW PLANS 20260421' contains technical drawings and architectural plans related to the upgrade of the fire alarm system on the B406 second floor at the Veterans Affairs Medical Center in Tomah, Wisconsin. It includes detailed component labeling and layout information essential for construction and installation. The document serves as a critical technical specification for the project, providing necessary design details for contractors and project managers. The version or date is indicated as 20260421, and it is intended to guide the final bid and construction phases of the fire alarm upgrade project.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for S02 Part 8 Fire Alarm New One-Line Diagrams 20260421: This document, dated April 21, 2026, contains detailed fire alarm system one-line diagrams and specifications for a new fire alarm installation. It includes wiring notes, device requirements, installation instructions, and system commissioning criteria. Key notes specify wiring gauge, device provisions, panel installation, and communication device placement. The document serves as a technical guide for the complete fire alarm system installation and acceptance by the VA, ensuring compliance with all related specifications and drawings.
PDF
PDF, High priority: read this first2 pages · amendment
HighAI Summary for SOL 36C25226B0014 - Upgrade Fire Alarm System (Bid Schedule & SOW): This document provides updates to pages 3 and 11 of solicitation 36C25226B0014 for the Upgrade Fire Alarm System project at the Tomah VA Medical Center, WI. It includes the Bid Schedule (CLIN 0001) and the Construction Statement of Work, specifying a project magnitude of $5M to $10M and a performance period of 460 calendar days after the Notice to Proceed.
DOCX
DOCX, High priority: read this first44 pages · ifb
HighAI Summary for Solicitation 36C25226B0014 Upgrade Fire Alarm System Tomah VA Medical Center: This document is a Standard Form 1442 solicitation (IFB) issued by the Department of Veterans Affairs on 08/12/2026 for project 676-22-110 to upgrade the fire alarm system at the Tomah VA Medical Center, Wisconsin. It is a sealed bid solicitation with offers due by 10:00 AM CST on 09/22/2026. The procurement is a 100% set-aside for SBA verified Service-Disabled Veteran-Owned Small Business Firms (SDVOSB) under NAICS 238210, with a project magnitude between $5M and $10M. The document includes instructions for submission, bonding requirements, site visit details, and certification requirements per VAAR 852.219-75. It also specifies that joint ventures must submit SBA certification proof. The solicitation contains critical contract terms, performance periods, and contact information for questions, making it a high priority document for contract response.
PDF
PDF, High priority: read this firstq-and-a
HighAI Summary for Tomah VAMC Upgrade Fire Alarm System RFI Responses: This document contains Request for Information (RFI) responses regarding the Tomah VAMC Fire Alarm System upgrade (Project 676-22-110). It provides technical clarifications on head-end server requirements, monitoring modules, relay interfaces, BMS integration, and the AES-IntelliNet wireless mesh radio network for FACP communication.
PDF
PDF, High priority: read this firstspecifications
HighAI Summary for Tomah VA Medical Center Fire Alarm System Upgrade - General Drawings: This document contains general drawings and project information for the upgrade of the fire alarm system at the Tomah VA Medical Center, located at 500 E Veterans St, Tomah, WI. It includes campus maps, building designations, project team details, and infection control risk assessment guidelines relevant to the project. The document is part of the final bid documents for project number 676-22-110 and provides essential technical and site layout information necessary for contractors and stakeholders involved in the fire alarm system upgrade.
PDF
PDF, High priority: read this firstamendment
HighAI Summary for Tomah VA Medical Center - Upgrade Fire Alarm System - Pre-Bid Addendum No. 002: Pre-Bid Addendum No. 002 issued November 4, 2026, for the Upgrade Fire Alarm System project (VA Project No: 676-22-110). This document modifies the bid documents by deleting specific requirements in Specification 28 31 00 regarding emergency voice communication and reinstating Specification Section 27 15 00 (Communications Structured Cabling) to address Pre-Bid RFIs 22-1, 22-2, and 22-3.
PDF
PDF, High priority: read this first28 pages · amendment
HighAI Summary for Upgrade Fire Alarm System - Pre-Bid Addendum No. 001: Issued September 29, 2026, for VA Project No. 676-22-110 at Tomah VA Medical Center. This pre-bid addendum modifies the original bid documents dated April 21, 2026, by updating 12 drawings, deleting 5 specification sections, adding 2 specification sections, and editing 3 others. Key changes include updates to fire alarm demolition and new work plans (specifically regarding MRI trailers and Room 1785), the addition of grounding and underground electrical specifications, and a reduction of the guaranty period services from 5 years to 1 year.
PDF
PDF, High priority: read this firstsow
HighAI Summary for VHA ICRA-1.5 July 2026 - High/Highest Risk Locations: VHA Infection Control Risk Assessment template for construction, renovation, and maintenance work, version VHAICRA-1.5 (July 2026). It provides instructions and tables for classifying activity category, affected areas, patient risk, and required infection prevention and control precautions, including completion permit guidance. The document also includes area-specific contact information and indicates the activity area relates to high/highest risk locations.
PDF
PDF, High priority: read this firstsow
HighAI Summary for VHA ICRA Template - Low Risk Locations / Fire Alarm Upgrade: VHA Infection Control Risk Assessment (ICRA) template for construction, renovation, and maintenance activities, VHAICRA-1.5 (July 2026). The document provides instructions for categorizing activity type, affected areas, patient risk, and required infection prevention controls, including tables for control measures and permit posting. It identifies Activity Category C and Overall Patient Risk Category Low, and lists the activity area as low risk locations with a POC of Robert Pidgeon.
PDF
PDF, High priority: read this firstsow
HighAI Summary for VHA ICRA Template - Medium Risk Locations, Fire Alarm Upgrade: VHA Infection Control Risk Assessment (ICRA) template for construction, renovation, and maintenance work. The document is a fillable assessment form used to classify activity type, affected areas, patient risk, and required infection prevention controls. It includes Table 1 with activity category C selected, Table 2 listing medium risk locations and POC information, and Table 3 showing an overall patient risk category of Medium. The template instructs users to apply control measures and completion requirements from later tables and includes a permit form for posting at the work site.
PDF
PDF, High priority: read this firstwage-determination
HighAI Summary for Wage Determination WI20260011 Building Mod 1 20260518: This document is a wage determination for various construction trades including pile drivers, carpenters, millwrights, and electricians across multiple counties in Wisconsin. It is identified as WI20260011 with a modification dated May 18, 2026. The document lists prevailing wage rates and fringe benefits effective from May and June 2025 for specific counties, providing critical labor cost information for federal or state construction contracts in the region.
PDF
PDF, Low priorityspecial-notice
LowAI Summary for 36C25226B0014 Pre-Bid Site Visit Sign-In: Sign-in sheet for the pre-bid site visit related to solicitation 36C25226B0014, "676-22-110 Upgrade Fire Alarm System at Tomah VA Medical Center, Tomah, WI." The notice lists the pre-bid site visit dates and time as September 25 and 27, 2026 at 9:00 am, the location as Building 407, 3rd floor, room 3720, and includes attendee/company/contact information. Dated 8/27/2026.
PDF
PDF, Low priorityspecifications
LowAI Summary for S02 - PART 2 - Civil Drawings: This document, titled 'S02 - PART 2 - Civil Drawings', appears to contain detailed civil engineering drawings and related notes for a construction project. It includes component descriptions, keyed notes, and references to concrete pads, bollards, and repair details. The document also lists consultants and project leader information. The content is technical and graphical in nature, focusing on design and construction specifications rather than solicitation or contract terms. Due to the nature of the content, it is classified as a specifications document with low priority for contract response.
PDF
PDF, Low priorityother
LowAI Summary for S02 - Part 4 - Fire Alarm Demo Plans: The document titled 'S02 - Part 4 - Fire Alarm Demo Plans' appears to be a set of plans related to fire alarm demolition. The content provided is empty or unreadable, with no visible text or details to analyze. Therefore, no specific procurement type or detailed summary can be determined from the available information.
PDF
PDF, Low priorityother
LowAI Summary for S02 Part 5 Fire Alarm Demo One-Line Diagrams 20260421: Document titled 'S02 Part 5 Fire Alarm Demo One-Line Diagrams' dated 2026-04-21. The content appears to be empty or unreadable, with no extractable information available.
PDF
PDF, Low priorityspecifications
LowAI Summary for S02 Part 9 Electrical Drawings 20260421: This document titled 'S02 Part 9 Electrical Drawings 20260421' appears to contain electrical drawings related to a procurement project. The content provided is largely empty or not readable, with no detailed text or specifications visible. The document likely serves as a supporting specification file for a contract, providing technical drawings for electrical systems. Due to the lack of readable content, no further details on version, purpose, or key content can be extracted.
PDF
PDF, Low priorityq-and-a
LowAI Summary for Solicitation 36C252-26-B-0014 Pre-Bid RFIs and Responses: Pre-bid RFI questions and VA COR responses for Project 676-22-110, Upgrade Fire Alarm System, under Solicitation 36C252-26-B-0014. Dated content includes clarification on SSHO and CQC manager requirements, infection control risk categories and barrier requirements, project design-build status, and related construction/infection control implementation questions. The document appears to be an RFI response addendum / Q&A compilation for bidding purposes.
Get AI-powered intelligence on this solicitation and the ones like it
Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.