Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity was posted on April 17, 2015. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

ZHTV110048-Replace-Roof-Data-Center

Closed
ZHTV110048-Replace-Roof-Data-CenterFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238160
New
SLED
GSW-27-40-01 GSW Student Success Center Flat Roof Project
Solicitation # GSW-27-40-01
Georgia Southwestern State University is soliciting sealed bids for the GSW Student Success Center Flat Roof Project (GSW-27-40-01) located at 240 Edgewood Avenue, Americus, Georgia. The scope of work involves a single prime contract for the installation of a Thermoplastic-Polyolefin (TPO) roofing system, including selective demolition, cast stone masonry, sheet metal flashing, and a lightning protection system compliant with UL 96A and LPI 175 standards. All roofing materials must meet FM Approvals 4450 or 4470 certifications and adhere to specific ASTM weathering and impact resistance standards. Bids must be submitted in a sealed envelope to Sierra Harvey, Director of Purchasing, by November 19, 2026, at 2:00 p.m. local time. Submissions must include a bid bond of at least 5 percent of the total bid; the successful contractor will be required to provide performance and payment bonds equal to 100 percent of the contract sum within 10 calendar days of award. While the contract is based on a lump sum price, the university may award the contract to a bidder other than the low bidder based on a review of bidder qualifications. The contractor is responsible for coordinating all work to maintain roofing warranties and must provide a Letter of Findings Certificate from Underwriters Laboratories or an LPI-IP certificate upon completion.
Georgia Southwestern State University

POSTED

about 21 hours ago

DEADLINE

in about 1 month

General Info

Agency

N/A

NAICS

238160 - Roofing Contractors

Place of Performance

WPAFB, WPAFB, OH, 45433, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts1 person available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts

Full Description

Show more
The United States Air Force, AFLCMC/Operational Contracting Branch, Wright-Patterson AFB, Ohio is seeking capabilities packages of potential sources, including Small Business (SB), HUBZone, Economically-Disadvantaged Woman-Owned (EDWO), and Service-Disabled Veteran-Owned (SDVO) small business concerns. This sources sought is for planning purposes only. The scope of this project is to Replace Roof Data Center, Facility 10271; Project Number ZHTV110048. Remove and re-roof approximately 91,000 SF (including walkway connector) of existing roof system including new roof materials, layout and details for insulation, flashing, expansion joints, scuppers, roof-access hatch, metal roof, asphalt roofing plies, gravel, gutters, downspouts, counter flashing, drip edges, cant strips, pipe collars and roof drains, etc. for facility 10271 at Wright Patterson AFB. According to 1989 As-Built drawings, existing Roof construction is metal deck, phenolic insulation, perlite fill, with 4-ply built-up roofing system and gravel. Pre-test the existing lightening protection system. Remove, store, and reinstall all lightening protection system components in order to remove existing roof and install new roof. Replace any damaged components to provide a complete and usable lightening protection system at project completion. Facility is considered an Electronic Equipment Facility/Data Center and the Lightening protection system must comply with the grounding requirements specific for this type of AF Facility. Remove, temporarily store, and reinstall all existing electrical, communications, security, and utility equipment located on the roof-top in order to install new roof system. Flush out roof drains and storm piping and provide new ring clamp and bolts for existing roof drains. Provide all new walk treads. Provide all new flashing. Provide all new storm collars. Provide all new pitch pans and all new pipe flashing. Complete and usable roof system is required at completion of project.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS