Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, August 5 at 2:00 PM EDT

Register Free →

NEW JERSEY TURNPIKE AUTHORITY 1 TURNPIKE PLZ WOODBRIDGE NJ 07095 USA

UEI: SLED_F1F50EB63D7B5E57

NEW JERSEY TURNPIKE AUTHORITY 1 TURNPIKE PLZ WOODBRIDGE NJ 07095 USA is a federal contractor, registered under UEI SLED_F1F50EB63D7B5E57. It has been awarded $72,240 across 1 federal contract. Primary work spans Unknown NAICS. Top awarding agencies include Base Cape COD(00052).

Contact Information

Registration and classification details

Registration

UEI Code

SLED_F1F50EB63D7B5E57

Federal Contracting Overview

Award totals, agency breakdown, NAICS distribution, and geographic footprint.

Key Performance Metrics

Awards Count

0

All time

Active

0

Currently performing

Completed

0

Past period of performance

Total Awards

All time

Contracts

Prime · all time

Subcontracts

Sub · all time

Grants

Prime · all time

Subgrants

Sub · all time

Award Analytics & Distribution

Awards by Agency
Base Cape COD(00052)$72.2K100%
Awards by NAICS
- Unknown NAICS$72.2K100%
Awards by Agency Over Time
Export
Awards by Place of Performance

Open opportunities in NEW JERSEY TURNPIKE AUTHORITY 1 TURNPIKE PLZ WOODBRIDGE NJ 07095 USA's top NAICS codes and agencies

NAICS: 238210
New
Federal
Electrical Transformer Replacement – Building 112 (Transformer 523)The contract entails the complete removal and replacement of a 750 KVA transformer at Building 112 in Buzzards Bay, requiring full electrical disconnection, safe mechanical handling, adherence to stringent safety protocols, and thorough re-commissioning to restore full operational capacity. The work must be performed in compliance with all applicable electrical and industrial safety standards, ensuring zero disruption to critical site operations during the transition. All phases of the project, from rigging and transportation to final testing and documentation, must be executed by qualified personnel with proven experience in high-voltage transformer replacement. This subcontract is designated as a Total Small Business Set-Aside under NAICS code 238210, restricting eligibility to small businesses as defined by the SBA. The opportunity was posted on July 22, 2026, with a response deadline of August 3, 2026, and is managed by the Department of Homeland Security under Base Cape COD(00052). The place of performance is strictly limited to the specified location in Buzzards Bay, Massachusetts, with no flexibility for alternate work sites. Successful bidders must demonstrate capacity to execute the scope without reliance on non-small business entities and must comply with all federal contracting requirements including labor, environmental, and safety regulations.
Base Cape COD(00052)

POSTED

5 days ago

DEADLINE

in 8 days
View Details
NAICS: 811310
New
Federal
AIRFIELD LEAKING TRANSFORMERThe Contractor is tasked with removing and replacing existing airfield lighting transformers at U.S. Coast Guard Base Cape Cod on Joint Base Cape Cod in Buzzards Bay, Massachusetts. The scope includes three identified transformers: two single-phase 37.5 KVA units manufactured by McGraw Edison located near Building 614 adjacent to Runways 23 and 14, and one three-phase 1500/1680 KVA unit from ABB near Building 3181 parking. Each transformer has detailed technical specifications including voltage ratings, winding materials, impedance, weight, and connection settings that must be verified and matched during replacement. The Contractor must also investigate potential oil leaks in the ABB unit, analyze feasibility for repair or replacement, and handle proper disposal of all removed equipment. An optional fourth transformer, a 15 KVA single-phase unit near Building 195 and Runway 5, is included for bid consideration. All work must be performed with full personnel, equipment, supervision, and material support as required for safe and compliant airfield operations. The solicitation, numbered 31125260000817, is a Total Small Business Set-Aside under NAICS code 811310, with proposals due by August 3, 2026. The contract is managed by the Department of Homeland Security through Base Cape Cod, with primary point of contact Steve Simpson and secondary contact Adam Gasparre. Performance is strictly limited to the specified location at Buzzards Bay, MA, 02542. The Contractor must adhere to all technical requirements, safety standards, and environmental protocols associated with handling and disposing of electrical equipment, particularly those containing mineral oil. All work must ensure uninterrupted airfield lighting operations and compliance with federal aviation and environmental regulations.
Base Cape COD(00052)

POSTED

5 days ago

DEADLINE

in 8 days
View Details
NAICS: 562112
Federal
COAST GUARD BASE CAPE COD GUN RANGE CLEANING/MAINTENANCEThe U.S. Coast Guard, under the Department of Homeland Security at Base Cape Cod in Buzzards Bay, Massachusetts, is soliciting services for the comprehensive cleaning and maintenance of the Small Arms Firing Range (SAFR), associated lobby areas, and heating, exhaust, and ventilation systems. This procurement is structured as a Total Small Business Set-Aside under FAR 19.5 with NAICS code 562112, restricted to small businesses, and requires full compliance with federal and state regulations including OSHA standards for lead exposure (29 CFR 1910.1025), hazardous waste handling (29 CFR 1910.120 and 40 CFR 260–273), respiratory protection (29 CFR 1910.134), and Massachusetts-specific rules such as 454 CMR 22.04 for lead abatement and 310 CMR 30 for hazardous waste. Contractors must submit a Company Profile, Quality Control Plan with staffing and training schedules, proof of state licensure for lead abatement, and Certification of Insurance per FAR 52.228-5, all delivered via PC-compatible CD-ROM with the proposal. Training records for OSHA 1920.120 hazardous waste and annual lead abatement must be provided two weeks before Notice to Proceed. Key deliverables include quarterly preventative maintenance on the Savage Range Systems Model 800W Drag Conveyor, airflow verification at the firing line at one, three, and five feet heights documented in CFM, and adherence to technical manuals including NEHC TM6290.99-10 Rev.1 and operational manuals for ventilation and bullet trap systems. Hazardous waste, including lead-contaminated protective clothing and debris, must be properly packaged, labeled per OPNAVINST 5100.23 and 29 CFR 1910.120, contained in containers no larger than 55 gallons without COR approval, and shipped with a Hazardous Waste Manifest reviewed and signed by the Environmental Health & Safety office; non-hazardous waste must be validated with TCLP analysis showing lead concentrations below 5.0 ppm. The contract mandates an on-site Project Manager with at least five years of experience, immediate workforce replacement within two hours of notification, and a comprehensive Site-Specific Health and Safety Plan covering hazard assessment, decontamination procedures, medical surveillance
Base Cape COD(00052)

POSTED

14 days ago

DEADLINE

in 20 days
View Details
NAICS: 541990
Federal
FUEL TANK INTEGRITY TESTINGThe contract requires the contractor to perform comprehensive external and internal inspections of aboveground fuel tanks and potassium sodium tanks at USCG Base Cape Cod in Bourne, MA, over a four-year period with a base year and three option years. The scope includes external inspections of six aboveground fuel tanks—two 10,000-gallon gasoline tanks and three JP-8 aviation fuel tanks (one 30,000-gallon and two 15,000-gallon)—as well as two 5,000-gallon potassium sodium tanks located behind Building 124. Internal inspections and wall thickness measurements are required only on the 30,000-gallon and two 15,000-gallon JP-8 tanks adjacent to Taxiway Delta, and all work must comply with Steel Tank Institute SP001 and API 653 standards. The contractor must deliver detailed reports on tank conditions, including observed deterioration, test results, and estimated remaining service life, along with repair cost estimates. All work must adhere to Federal, State, and Local environmental regulations, with full compliance to OSHA standards and directives from the Base Safety Officer and Fire Department. The contractor is required to provide all personnel, equipment, materials, and supervision, with a licensed supervisor present onsite at all times who must be able to read, write, and speak English and have authority to approve minor modifications under $2,000. All personnel must be skilled and experienced. Prior to access, employees must undergo an NCIC background check, with personal information submitted seven days in advance, and all vehicles must meet Base entry requirements including valid insurance, registration, and driver’s license. The contractor must submit a Schedule of Work for approval before starting, complete daily logs submitted weekly, and submit a Safety Plan and Environmental Protection Plan—including a Storm Water Protection Plan—within 15 days of award, along with a Base Access Request Form within five days. Acceptance by the Contracting Officer’s Representative is mandatory and contingent upon site cleanup, punch list resolution, and all deliverables being submitted via approved forms. The contract mandates compliance with FAR 52.212-4, 52.222-90 (addressing DEI discrimination), and 52.246-21, and places full responsibility on the contractor for any damage to property, requiring repairs at their expense to original condition. Invoices must be submitted through IPP.gov, and
Base Cape COD(00052)

POSTED

about 2 months ago

DEADLINE

N/A
View Details