16390786 - SECTOR NORTHERN NEW ENGLAND Repair Exterior Buildings 1, 2, and 5 Sector NNE (FY27)
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
The United States Coast Guard is seeking a small business contractor to perform comprehensive exterior repairs on Buildings 1, 2, and 5 at Sector Northern New England in South Portland, Maine. The project focuses on restoring the structural integrity and operational readiness of aging masonry buildings, specifically targeting the replacement or repair of siding, roofing, gutters, downspouts, snowguards, windows, and various door types. Key maintenance tasks include masonry re-pointing, window caulking, and the abatement of deteriorated lead-based paint in the boiler room. Critical safety and compliance priorities include repairing cracked concrete foundations to stop water infiltration into electrical spaces, which currently poses a risk of system failure. Additionally, the scope of work involves repairing spalled concrete walkways, stairways, and ramps to ensure continued ADA compliance. These efforts are intended to create a weathertight envelope and prevent further interior damage to occupied spaces within the facility.
General Info
Place of Performance
South Portland, ME, USASet-Aside
Documents
0AI Contract Breakdown
Uniform Contract FormatNo documents to break down
The breakdown needs solicitation documents. None were found from this contract's source.
Timeline
Organization & Contact Information
Full Description
• Window caulking repair • Masonry repairs • ADA Ramp/Railings repair • Concrete walkway/stairway repairs • Replace Doors • Repair foundation/water infiltration • Abate deteriorated LBP in boiler room • Minor roof repairs
BACKGROUND: Buildings 1 & 2 are masonry exterior structures that were building approximately 100 years ago. Both buildings are aging and need repairs to extend operational readiness for the Sector personnel.
The exterior masonry requires re-pointing and repairs to ensure a weathertight envelope. In addition the windows and doors are leaking during adverse weather and require repair/reseal. This is causing damages to finished occupied spaces within the buildings.
The concrete foundation is cracking and water is infiltrating into the mechanical/electrical spaces. The leaking wall is located where the building electrical panels and wiring are located, posing an electrical risk and failure of system. Exterior concrete ramp is spalled and requires repairs to maintain ADA compliance.
Similar Contracts
Same NAICS industry code
More opportunities from Department of Homeland Security → United States Coast Guard
Same awarding agency
Ready to Pursue This Opportunity?
Get AI-powered intelligence on this solicitation and the ones like it
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS