182d Airlift Wing Peoria, Illinois Repair Base Fire Alarm System
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
The U.S. Air Force, through the USPFO for Illinois National Guard at the 182nd Airlift Wing in Peoria, Illinois, is seeking potential sources for the repair and upgrade of the base fire alarm system under solicitation number A046027. This pre-solicitation notice, published on June 25, 2026, anticipates a contract valued between $500,000 and $1,000,000 and is designated as a Total Small Business Set-Aside under FAR 19.5 with NAICS code 236220 for Construction of Buildings. Interested contractors must submit a written response no later than July 6, 2026, at 3:00 p.m. CST, including a positive statement of intent to bid as a prime contractor, a completed and signed Sources Sought Information Response Form, a detailed listing of three years of past projects with contract numbers, values, locations, and roles (prime or subcontractor), and a brief outline of proposed resources, subcontractors, and key personnel. All submissions must be emailed to the points of contact, SSgt Emily Scully and 1st Lt Nicholas Marzinzik, with the exact subject line specified, and no faxed or hard-copy responses will be accepted. The project scope, as outlined in the Statement of Work, requires the replacement of existing fire alarm panels, initiating devices, and TrueSite Workstations across more than 27 buildings with COINv3-compatible equipment manufactured by Simplex, transitioning all systems to an ethernet-based infrastructure and integrating them with central monitoring stations, the Mass Notification Warning System, VESDA, and suppression systems. All work must comply with UFC 3-600-01, ANG ETL 15-01-03, OSHA regulations, and FAR 52.223-3 for hazardous materials, with inspections and acceptance occurring at the installation site upon substantial completion. Contractors must also comply with base access protocols, including PIV credentialing, AT Level I Antiterrorism Training, and adherence to local security and force protection conditions. The response is limited to five typewritten pages and must include full CAGE and UEI identifiers along with socioeconomic status certifications, with the understanding that if insufficient small business responses are received, the procurement may be opened to unrestricted competition. No pricing, CLIN details, evaluation factors, or
General Info
Agency
NAICS
Place of Performance
Peoria, IL, 61607, USASet-Aside
Timeline
Response Deadline
Organization & Contact Information
Full Description
Repair Base Fire Alarm System
Category: Y –Construction of Structures and Facilities—Potential Sources Sought
Date Published: June 25, 2026
Contracting Office: USPFO for Illinois National Guard, 182nd Airlift Wing, Mission Support Contracting, 2416 S. Falcon Blvd, Peoria, IL 61607
Points of Contact:
- SSgt Emily Scully: emily.scully.1@us.af.mil
- 1st Lt Nicholas Marzinzik: nicholas.marzinzik@us.af.mil
Subject Line for Responses: Sources Sought Repair Base Fire Alarm System
Synopsis: REPAIR BASE FIRE ALARM SYSTEM sources sought.
The purpose of this synopsis is to gain knowledge of potential sources for this project including interested
Small Business sources. This notice is for PLANNING PURPOSES ONLY. All interested parties should respond. The 182d Airlift Wing of the Illinois Air National Guard, Illinois intends to issue a solicitation and award of a contract to “Repair Base Fire Alarm System”.
The magnitude of this project is Between $500,000 and $1,000,000. All interested concerns willprovide this office, in writing, a notice stating their positive intent to submit a proposal as a prime contractor no later than 6 July 2026 3:00P.M. CST.
This notification, which shall not exceed five typewritten pages, must include (1) positive statement of intent to bid as a prime contractor, and (2) a completed and signed Source Sought Information Response Form and (3) A listing of projects completed during the past three years, both for government and private industry. The type of project, dollar value, Contract number, location, and Point of Contact are to be included. Indicate if you were prime or subcontractor, and if subcontractor, provide the name and point of contact for the prime contractor. (4) A brief outline of resources, subcontractors, and key personnel that would be used to accomplish the contract. In the event adequate Small Business contractors are not available for adequate competition for this project, it may be advertised as unrestricted.
Information shall be provided via email to: emily.scully.1@us.af.mil and nicholas.markzinzik@us.af.mil Include the following in the subject line "Sources Sought Repair Base Fire Alarm System". No facsimile responses will be honored.
Attachment 1: SOW_Repair Base Fire Alarm System (2)
Attachment 2: Sources Sought Information Response Form
