Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Government of Canada was posted on June 24, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

26-58018 Laboratory Wind Wall System, Amendment #4, Question and Answer 5

Closed
26-58018International

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 333413
New
Federal
ODMS FAN ASSEMBLY, CENTRIFUGAL
Solicitation # 70ZU0127P21014B00
The United States Coast Guard Surface Forces Logistics Center is soliciting quotations for 11 centrifugal fan assemblies (NSN 4140-01-557-8316, OEM PN T-HLZ-225T) for use in engineroom variable frequency drive controllers. These items must be procured from the original equipment manufacturer, Novenco Marine and Offshore A/S, or its authorized U.S. distributor, as they have been specifically modified for Novenco system designs. Brand name parts are mandatory, though equal products may be considered if they meet all salient physical and functional characteristics as determined by the USCG. This is a firm fixed price purchase order to be awarded on a best value basis, considering technical requirements, delivery timeframe, and price. There is no set aside used for this procurement. Delivery is required F.O.B. Destination to the Surface Forces Logistics Center in Baltimore, Maryland. Strict packaging and marking requirements apply; items must be individually packaged per MIL-STD-2073-1E Method 10, packed in ASTM-D5118 double-wall fiberboard boxes, and marked according to MIL-STD-129R with ISO/IEC-16388-2007 Code 39 symbology. Failure to meet these packaging standards will result in the warehouse rejecting the items. Quotations must be emailed to Courtney Gustin by November 30, 2026, at 10:00 am Eastern Time, and must include a completed FAR 52.212-3 representation and certification and a disclosure regarding inverted domestic corporation status.
CG-SEA-C21

POSTED

about 10 hours ago

DEADLINE

in 6 days

AI Contract Overview

Show more

The National Research Council of Canada's Aerospace Research Centre is seeking a turnkey Laboratory Wind Wall System to support the Drone and Flight Autonomy Laboratory at the Mirabel site. The system is designed for research into the performance, control, and safety of mid-size unmanned aircraft operating in complex aerodynamic environments, such as urban wind fields and ship airwakes. The requirement includes the design, fabrication, delivery, and commissioning of a system featuring an open-jet test section with a nominal jet face of 5m x 5m, positioned 3m above ground level. Technical specifications mandate a maximum axial wind speed of 21-22 m/s, specific ramp-up and ramp-down acceleration capabilities, and the ability to operate in temperatures ranging from -20°C to +30°C while meeting IP 34 protection standards. The contract includes an optional expansion scope to increase the system size to 7m x 7m, which must be structurally and functionally compatible with the base system. Evaluation of proposals is based on a combined rating consisting of 60% technical merit, 15% price, and 25% Canadian Value-Added, with a 10% price preference applied to Canadian suppliers. The successful offeror must provide a minimum one-year warranty, comprehensive technical documentation in both English and French, and ensure all electrical components are CSA certified. Final assembly and integration will take place at the NRC Mirabel laboratory, with all deliverables due by March 31, 2028.

General Info

NRC seeks a turnkey Laboratory Wind Wall System for drone research in Mirabel.

Documents

25
PDF, High priority: read this first2 pages · amendment
High
PDF, High priority: read this first2 pages · amendment
High
PDF, High priority: read this first2 pages · amendment
High
PDF, High priority: read this first2 pages · amendment
High
PDF, High priority: read this first2 pages · amendment
High
PDF, High priority: read this first2 pages · q-and-a
High
PDF, High priority: read this first1 page · q-and-a
High
PDF, High priority: read this first1 page · q-and-a
High
PDF, High priority: read this first2 pages · q-and-a
High
PDF, High priority: read this first71 pages · rfp
High
PDF, High priority: read this first71 pages · rfp
High
PDF, High priority: read this first2 pages · amendment
High
PDF, High priority: read this first2 pages · amendment
High
PDF, High priority: read this first2 pages · amendment
High
PDF, High priority: read this first76 pages · rfp
High
PDF, High priority: read this first76 pages · rfp
High
PDF, High priority: read this first2 pages · amendment
High
PDF, High priority: read this first2 pages · amendment
High
PDF, High priority: read this first2 pages · amendment
High
PDF, High priority: read this first2 pages · amendment
High
PDF, High priority: read this first2 pages · amendment
High
PDF, High priority: read this first2 pages · amendment
High
PDF, High priority: read this first3 pages · q-and-a
High
PDF, Medium priority1 page · q-and-a
Medium
PDF, Low priority1 page · q-and-a
Low

Read all 25 documents

Every page of every file, in your free workspace.

Read the documents

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

View Full Breakdown

This one is closed. Find the next one like it.

Open contracts like this one, right now:

  • FAN, CENTRIFUGALOpen now, due in 13 days
  • IMPELLER, FAN, AXIALOpen now, due in 13 days
See open contracts like this

Ask CLEATUS

I've read this contract. Ask me anything.

Timeline

9 updates
PhaseClosed
Posted

Solicitation

Notice updated

The notice description changed.

Notice updated

The notice title changed. The notice description changed.

Notice updated

Response deadline changed from Jun 30, 2026 to Jul 30, 2026. The notice title changed. The notice description changed.

Notice updated

Response deadline time changed from 7:00 PM UTC to 2:00 PM UTC on Jul 30, 2026. The notice title changed. The notice description changed. The point of contact changed.

Notice updated

Response deadline time changed from 2:00 PM UTC to 7:00 PM UTC on Jul 30, 2026. The notice description changed. The point of contact changed.

Notice updated

Response deadline changed from Jul 30, 2026 to Aug 21, 2026. The notice title changed. The notice description changed.

Notice updated

Response deadline changed from Aug 21, 2026 to Sep 4, 2026. The notice title changed. The notice description changed.

Notice updated

Response deadline changed from Sep 4, 2026 to Oct 1, 2026. The notice title changed. The notice description changed.

Notice updated

The notice title changed. The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyGovernment of Canada → National Research Council of Canada
Contacts1 person available
OfficeN/A

Full Description

Show more
Question and Answer #5 and Amendment #4 RFP 26-58018 Laboratory Wind Wall for Unmanned Aircraft Complex Flow Testing This amendment is issued to modify the solicitation, please see tender documents for details. ALL OTHER TERMS AND CONDITIONS REMAIN THE SAME ___________________________________________________________________________________________________________________________________________ Question and Answer #4 and Amendment #3 RFP 26-58018 Laboratory Wind Wall for Unmanned Aircraft Complex Flow Testing This amendment is issued to modify the solicitation, please see tender documents for details. ALL OTHER TERMS AND CONDITIONS REMAIN THE SAME ___________________________________________________________________________________________________________________________________________ Amendment #2 RFP 26-58018 Laboratory Wind Wall for Unmanned Aircraft Complex Flow Testing This amendment is issued to modify the solicitation, see tender documents for details. ALL OTHER TERMS AND CONDITIONS REMAIN THE SAME _____________________________________________________________________________________________________________________________________________ RFP 26-58018 Laboratory Wind Wall for Unmanned Aircraft Complex Flow Testing Question and Answer #3 is posted on Canada Buys 09 June 2026. _______________________________________________________________________________________________________________________________________________ RFP 26-58018 Laboratory Wind Wall for Unmanned Aircraft Complex Flow Testing Question and Answer #2 is posted on Canada Buys 08 June 2026. _______________________________________________________________________________________________________________________________________________ Amendment #1 RFP 26-58018 Laboratory Wind Wall for Unmanned Aircraft Complex Flow Testing This amendment is issued to modify the solicitation following Question and Answer #1 posted on Canada Buys 06 June 2026. See the modification to the solicitation below. MODIFICATIONS TO THE SOLICITATION ____________________________________________________________________________________________________ At Annex Statement of Requirement, sub-section 1.1 Technical Requirement/Specifications, 1.1.2 Wind Wall Airflow Performance: DELETE: section e. in its entirety; and REPLACE with: e. The System must achieve ramp-up acceleration = 10 m/s² and ramp-down deceleration = -5 m/s². The swirl number at the TP must be = 0.5 (non-dimensional). ALL OTHER TERMS AND CONDITIONS REMAIN THE SAME __________________________________________________________________________________________________________________________________________________________________________ RFP 26-58018 Laboratory Wind Wall for Unmanned Aircraft Complex Flow Testing The National Research Council of Canada’s - Aerospace Research Centre (NRC AERO) has a requirement for the design, fabrication, delivery, and commissioning of a Laboratory Wind Wall System (The System). The System will support NRC’s Drone and Flight Autonomy Laboratory (DFAL) in research focused on the performance, control, and safety of mid-size unmanned aircraft (drones) operating in complex aerodynamic environments, such as ship airwakes and urban wind fields, across all Canadian seasons. The System must provide controlled, repeatable, and configurable airflow conditions for testing unmanned aircraft in free flight. BACKGROUND: The aerodynamic performance and stability of unmanned aircraft operating in complex wind environments are not yet fully understood, particularly across different propulsion configurations. NRC’s research program requires a large-scale Wind Wall System capable of generating controlled wind and turbulence conditions for outdoor free-flight testing of mid-size unmanned aircraft. The System will form part of a new outdoor test capability at NRC’s Drone and Flight Autonomy Laboratory (DFAL) located at the NRC Mirabel site. This facility will enable the evaluation of aircraft systems and Small and Medium Enterprise (SME) developed technologies under controlled aerodynamic conditions representative of operational environments in Canada, including ship airwakes and urban wind fields. DEFINITIONS: Wind Wall A vertically stacked array of fans that generate a horizontal wind flow-field exiting from one vertical face. The overall Wind Wall dimensions in this document refer to the exit face width and exit face height of the fan array. The Wind Wall depth includes only the fans and supporting structure (no airflow contractions or surrounding building) to minimize the System footprint. Marketable Wind Wall System A finished, polished version that meets quality standards, is compliant with regulations, and is ready for sale at scale or customized. Turbulence Intensity Turbulence intensity refers to local turbulence intensity for which the reference wind speed is measured locally. 1.0 REQUIREMENT: The Offeror must design, manufacture, deliver, and commission a turnkey Laboratory Wind Wall System that meets or exceeds the technical and operational requirements defined in this Statement of Requirement (SOR). The System must be capable of generating controlled, repeatable, and complex airflow conditions suitable for unmanned aircraft free flight testing. 1.1 Technical Requirements/Specifications 1.1.1 Wind Wall System i. The System must include an open-jet test section to allow for free-flight testing of aircraft. ii. The Wind Wall jet face must have nominal dimensions of 5 m × 5 m (± 0.25 m tolerance). iii. The bottom of the jet face must be positioned 3 m above ground level, and the center of the test region must be 5.5 m above ground. iv. The Test Plane (TP) must be located 5 – 6 m downstream of the Wind Wall, with a minimum of 4 m x 4 m of uniform jet flow. v.  The design must allow for an optional expansion of the Wind Wall to 7 m × 7 m (± 0.25 m in width and height), as described in Section 1.1.6 Optional Expansion Scope. - The bottom of the Wind Wall must remain 3 m above ground level. - The increase in width must be symmetric about the lateral centre of the Wind Wall exit face, and the height extension must occur upward from the top edge of the existing structure. - The additional fan modules required for the optional configuration must be equivalent in size, capacity, and performance to those used in the 5 m × 5 m base Wind Wall system. - The optional expansion must be structurally and functionally compatible with the base Wind Wall foundation, controls, and safety systems. 1.1.2 Wind Wall Airflow Performance a. The maximum axial wind speed at the TP must be 21–22 m/s, with maximum axial turbulence intensity of = 7%. b. The System must provide adjustable turbulence intensity at the TP ranging from 7% to 25% in the streamwise component, while maintaining a maximum wind speed of = 15 m/s. c. The minimum axial wind speed at the TP must be 1 m/s. d. The fan array design must support gradients of 2 m/s per metre (horizontal or vertical) and integral length scales of 2–50 m. e. The System must achieve ramp-up acceleration = 10 m/s² and ramp-down deceleration = -5 m. The swirl number at the TP must be = 0.5 m/s². f. Each fan must support independent and synchronized control, with incremental speed changes = 0.2 m/s. 1.1.3 Equipment and System Requirements The System must: • operate without performance derating from 0 °C to +30 °C; • have minimal performance derating from -20 °C to +30 °C; • be suitable for cold starts (-20 °C to +20 °C) for = 800 cycles; • be storable from -20 °C to +60 °C; • be designed, constructed, and tested so it can operate normally and safely in light rain or snow conditions, without loss of performance, safety, or durability, and must meet at least IP 34 protection standards; • have a minimum operational lifespan of 20,000 hours; • be delivered as a turnkey solution, fully operational upon commissioning and compliant with all specified requirements. The System’s high-voltage components (> 750 V) must be enclosed in an IP 65-rated cabinet. The Wind Wall electrical system must be compatible with standard North American industrial electrical systems operating at 60 Hz. The Offeror must specify the required electrical service for the system, including voltage, phase configuration, total connected load (kW), apparent power (kVA), and power factor at full load. Where the proposed system requires a voltage different from typical Canadian building distribution systems (for example, 600/347 VAC or 208/120 VAC), the Offeror must provide the necessary transformers, converters, or other power conditioning equipment as part of the Wind Wall System. The Offeror must provide the estimated peak electrical demand and total connected load for the Wind Wall System as part of the proposal so that NRC can assess compatibility with the available site electrical infrastructure. All electrical equipment supplied as part of the Wind Wall System must be certified by the Canadian Standards Association (CSA) or by another certification body accredited for use in Canada and acceptable to the authority having jurisdiction. The electrical installation and equipment must comply with the Canadian Electrical Code (CSA C22.1) and all applicable provincial regulations. 1.1.4 Structural Support and Grade-Level Surface Interface Requirements a. The grade level foundation and support framing must be supplied and installed by the Offeror. The design must be structurally engineered to safely withstand all static loads (including system weight and terrestrial wind conditions) and dynamic loads generated during wind-on testing under all anticipated operational conditions. b. The Wind Wall support framing must be mechanically anchored to the grade level foundation (pad) using fastening and reinforcement methods appropriate for the loading conditions described in paragraph (a). c. The Offeror must ensure that all foundation, structural, and anchoring details comply with applicable Canadian building codes, engineering standards, and site-specific geotechnical recommendations. d. All design calculations, load assessments, and anchoring specifications must be sealed by a licensed professional engineer and included in the Offeror’s submission for NRC review and approval prior to fabrication and installation. e. The structure of the Wind Wall system must: • be self supporting and capable of being anchored to an engineered foundation; and • comply with the wind load requirements of the National Building Code of Canada (NBCC) and any other applicable codes and standards. 1.1.5 Operational Requirements • Control Software Compatibility: The control software must be compatible with common operating systems such as, but not limited to, Microsoft Windows 10 or 11 (Professional or Enterprise editions) and current Linux distributions (for example, Ubuntu LTS, Red Hat Enterprise Linux, or Debian). Other platforms may be considered if full functionality, interoperability, and technical support are demonstrated. • Information Security and Data Protection: The System must adhere to recognized information security and data protection practices to safeguard operational and research data. All communications and data transfers must use secure, encrypted protocols (such as HTTPS, SFTP, or TLS 1.2 or higher) to ensure confidentiality and integrity. • Data Output and Synchronization: Wind profile output data must be GPS timestamped. The software must support an external trigger for synchronized data logging and must allow automation, storage, and repetition of Test Plane (TP) wind profiles for consistent experimental conditions. • System Reliability and Redundancy: The system must allow continued operation in the event of an individual fan failure without compromising overall airflow control or test stability. • Safety Controls: An emergency stop system must be installed at the operator location, providing immediate system shutdown capability in accordance with applicable electrical and mechanical safety standards. 1.1.6 Optional Expansion Scope The National Research Council of Canada (NRC) reserves the right to exercise an option to obtain a larger Wind Wall system at the time of contract award or during the contract period by way of a contract amendment. a. Scope of the Option • The design of the base Wind Wall must allow for an optional expansion to 7 m × 7 m (± 0.25 m in width and height). • The bottom of the Wind Wall must remain 3 m above ground level in both the base and expanded configurations. • The increase in width must be symmetric about the lateral center of the Wind Wall exit face, and the height extension must occur upward from the top edge of the existing structure. • The additional fan modules required for the optional configuration must be equivalent in size, capacity, and performance to those used in the 5 m × 5 m base Wind Wall system. • The optional expansion must be structurally and functionally compatible with the base Wind Wall foundation, support framing, controls, power distribution, and safety systems. • The expanded system must maintain equivalent design, safety, and performance standards as the base Wind Wall system, with proportional scaling of structural and control components. • The optional configuration must be capable of achieving wind speeds exceeding 21 m/s and supporting applications consistent with small aviation testing and/or wind simulation in research environments. b. Bidder Requirements Bidders must include technical specifications and design drawings for the optional configuration and pricing details for the 7 m × 7 m Wind Wall in Annex Basis of Payment, Optional Table 1. Pricing for the optional system must be identified separately from the base system pricing in the financial proposal. Bidders must indicate any lead time, production schedule, or delivery considerations associated with the larger configuration. The optional design must remain interoperable with the base system’s control software, data interfaces, and safety features. c. Contractual Option The NRC may, at its sole discretion, exercise this option in whole or in part at the time of contract award or at a later date during the contract period. Exercising the option will be subject to the same terms and conditions as the base contract, except where otherwise specified and agreed upon in writing. The Offeror must honour the proposed pricing and delivery commitments for the optional configuration for a period of up to 14 months following contract award. 2.0 WARRANTY AND SUPPORT: • Minimum one (1) year warranty covering all parts and labour. • Offeror must provide technical support (phone and email) for the duration of the warranty. 3.0 MAINTENANCE AND HARDWARE SUPPORT: The Offeror must provide hardware support throughout the warranty period, including: • Replacement of defective components; • Troubleshooting and repair assistance; • Access to a technical support team by phone or email; • A detailed maintenance and service manual must be provided with the System. 4.0 TECHNICAL DOCUMENTATION: The Offeror must supply a comprehensive technical manual, including system diagrams, maintenance and troubleshooting procedures, and instructions for live and recorded data collection. 4.1 References • National Building Code of Canada, latest edition; • Applicable Canadian Standards Association (CSA) standards for electrical equipment and industrial control panels; • Canadian Electrical Code (CSA C22.1), latest edition; • International Electrotechnical Commission (IEC) and European Norm (EN) (IEC/EN) standards applicable to electrical safety and Ingress Protection (IP) ratings. 5.0 DELIVERY ADDRESS: National Research Council Canada YMX Innovation Centre 9800 Rue Irénée-Vachon Mirabel, Québec J7N 3C5 Canada 6.0 LANGUAGE OF WORK: • All deliverables, including reports, documentation, and training materials, must be provided in both English and French, in accordance with the Official Languages Act. • Meetings and communications will be conducted primarily in English, with French language support provided for stakeholders as required. 7.0 LOCATION OF WORK: • Manufacturing of sub-assemblies: at the Offeror’s facilities. • Final assembly and integration: at NRC’s Mirabel laboratory site adjacent to the wind wall foundation. • For construction site access, if NRC visitor requirements apply during the assembly period, Persons Granted Access (PGA) requirements must be arranged prior to on-site work activities. 8.0 TRAVEL AND DELIVERY: • All travel and delivery costs are to be included in the Offeror’s pricing. • No travel reimbursement will be provided. • Any additional travel must be pre approved in writing by the Project Authority and comply with the Government of Canada Travel Directive.

More opportunities from Government of Canada → National Research Council of Canada

Same awarding agency

NAICS: 237110
New
International
M-54 Parking Lot, Watermain and Storm Rehabilitation Project
Solicitation # 26-58200
The National Research Council Canada is soliciting bids for the M-54 Parking Lot, Watermain and Storm Rehabilitation Project located at 1200 Montreal Road, Ottawa, Ontario. This construction project involves the rehabilitation of parking lots, water mains, and storm sewer systems, with an estimated value between $500,001 and $2,000,000. Key requirements include mandatory site visits on November 10 or 12, 2026, and a final bid submission deadline of December 7, 2026. The scope of work encompasses temporary site controls for erosion and pollution, material management for building components, and adherence to standards such as the Canadian Environmental Protection Act and Green Globes 2019. The contract is governed by the Federal Prompt Payment for Construction Work Act, requiring payment within 28 calendar days of a proper invoice. Bidders must provide bid security, performance bonds, and labour and material payment bonds. Performance will be evaluated based on quality of workmanship, project management, contract management, and health and safety. Technical specifications require that all testing and inspection agencies be accredited by the Standards Council of Canada and that asphalt restoration complies with PPS 1010. There is no specified set-aside status for this solicitation.
Water and Sewer Line and Related Structures Construction

POSTED

about 17 hours ago

DEADLINE

in 13 days
View Details
NAICS: 334515
New
International
Purchase of two (2) Millimetre-Wave Frequency Extender Modules for a Vector Network Analyzers (VNAs) from 110 GHz to 170 GHz
Solicitation # 26-58131
The National Research Council Canada (NRC) Herzberg Astronomy and Astrophysics (HAA) is seeking the procurement of two millimetre-wave frequency extender modules to expand its measurement capabilities from 116 GHz to a range of 110 GHz to 170 GHz. These modules are essential for characterizing front-end components for low-noise receivers in radio astronomy and must be fully compatible with existing Keysight PNA N5227B or Rohde & Schwarz ZNA67 Vector Network Analyzers. Key technical requirements include a minimum guaranteed dynamic range of 110 dB and a typical dynamic range of 120 dB over at least 80% of the operating frequency range, utilizing a 10 Hz IF bandwidth and WR6.5 waveguide interface standards. The contract will be awarded to the compliant offer with the lowest evaluated price, provided it meets all mandatory technical criteria. Bids must be submitted electronically as separate technical and financial attachments by November 25, 2026, at 2:00 PM EST. The successful contractor must provide a 36-month warranty and deliver the equipment via Incoterms 2020 DAP to Victoria, British Columbia, by January 8, 2027. There is no set-aside status for this procurement. Payment will be made via direct deposit, EDI, or wire transfer within 30 days of receiving an undisputed invoice.
Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals

POSTED

1 day ago

DEADLINE

in 8 days
View Details

Get AI-powered intelligence on the opportunities still open

Every solicitation package arrives shredded into a compliance breakdown and matched to your past performance, with incumbent history and alerts on amendments and award.

Miguel
Hillary
Keith Deutsch
Christine

Join 900+ contractors already using CLEATUS