Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Pre-Solicitation opportunity from Department Of Veterans Affairs was posted on August 17, 2022. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

2815--Generator Maintenance

Closed
36C24522Q0941Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
Management & Training Corporation (MTC) is soliciting bids for the clutch replacement of a Kubota M8200 tractor with front wheel assist, no cab or loader, located at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The contractor is responsible for providing all transportation, labor, supervision, tools, and new manufacturer-specified parts to diagnose and repair the clutch assembly and power take-off (PTO) system. The scope of work includes disassembling tractor components, replacing friction discs, bearings, oil seals, O-rings, and the clutch release spring, resurfacing the flywheel, and replacing necessary hydraulic pipes and filters. Final acceptance is contingent upon the Facility Maintenance Department verifying proper clutch engagement and disengagement and confirming the PTO system operates correctly under load. This is a small business set-aside solicitation under NAICS code 811310, with a response deadline of November 3, 2026. Bids will be evaluated based on best value, requiring a lump sum fee, itemized costs, warranty information, and proof of necessary qualifications. Submission requirements include a bid sheet, a completed supplier packet with IRS Form W-9, proof of insurance, and applicable SBA certification letters. The contract incorporates various Federal Acquisition Regulation (FAR) clauses regarding small business utilization, equal opportunity, and labor standards, specifically adhering to Wage Determination No. 2015-4687 Revision 31 for Kentucky. Contractors must also comply with strict security protocols regarding non-public information and federal debarment disclosure requirements.
Earle C. Clements Job Corps Center

POSTED

about 4 hours ago

DEADLINE

in 4 days
NAICS: 811310
New
SLED
**Certified SB/DVBE Only** IFPQ Boiler Inspection, Maintenance, Repair, Testing, and Reporting in Los Angeles County
Solicitation # 07A6539
The California Department of Transportation (Caltrans) is soliciting price quotes for an Invitation for Price Quote (IFPQ 07A6539) to provide comprehensive boiler inspection, maintenance, repair, testing, and reporting services at the District 7 Office facility in Los Angeles, California. The scope of work includes annual and quarterly preventative maintenance for three Unilux water tube boilers and six boiler pumps, ensuring compliance with manufacturer standards, ASME Code, OSHA requirements, and South Coast Air Quality Management District standards. This is a set-aside solicitation exclusively for certified Small Business (SB), Microbusiness (MB), or Disabled Veteran Business Enterprise (DVBE) entities. The contract will be awarded to the responsible bidder offering the lowest price quote who meets all specifications. Key operational requirements include a 48-hour response time for routine service requests and a strict prohibition on subcontracting any portion of the work. The contractor must adhere to State General Prevailing Wage Rates for Los Angeles County and provide a payment bond for any service request exceeding 25,000 dollars. Required submission documents include a Price Quote Proposal, Bidder Certification Sheet, Non-Collusion Declaration, and certifications for California Civil Rights Laws and the Darfur Contracting Act. Invoicing is conducted monthly in arrears and must be accompanied by certified payroll records and DVBE utilization reports. The agreement is subject to a budget contingency clause, meaning it is enforceable only if sufficient funds are provided by the California State Legislature or the United States Government.
California Department of Transportation

POSTED

about 13 hours ago

DEADLINE

in 14 days
NAICS: 811310
New
SLED
Springfield Hospital Center Preventive Maintenance and Load Testing of Fifteen (15) Emergency Generators 2026
Solicitation # BPM059551
The Maryland Department of Health, Springfield Hospital Center, is soliciting bids under solicitation number BPM059551 for a one-year contract to provide preventive maintenance, emergency maintenance, minor repairs, and load testing for fifteen emergency generators at its Sykesville, Maryland campus. The period of performance is scheduled from approximately November 24, 2026, to November 23, 2027, with no renewal options. The scope of work requires four preventive maintenance visits per year, spaced three months apart, and one four-hour load bank test per generator annually. All services must be performed by fully trained and certified mechanics in accordance with Electrical Generating Systems Association standards and manufacturer recommendations. The contractor is responsible for all preventive maintenance costs and the first 500 dollars for both labor and parts per incident for emergency services or minor repairs. This is a Small Business Reserve solicitation, meaning only registered Small Business Reserve vendors are eligible for award. To qualify, bidders must possess a State of Maryland General Contractor's License, provide Electrical Generator Systems Technician Certification, and demonstrate at least five years of experience in providing similar services. The contract will be awarded to the responsible bidder who submits a responsive bid with the lowest total price. Invoicing is handled monthly via email or USPS, with payment terms of 30 days. Additionally, the contractor must adhere to strict sustainable packaging requirements, prohibiting the use of certain heavy metals and polystyrene foam.
09001-general Administration - Springfield Hospital Center

POSTED

about 15 hours ago

DEADLINE

in 14 days
NAICS: 811310
New
SLED
Dietary Equipment Service Agreement
Solicitation # BPM059212
The Maryland Department of Health, Clifton T. Perkins Hospital Center, is soliciting bids for a dietary equipment maintenance services contract under solicitation BPM059212. This is a Small Business Reserve Procurement limited to vendors certified by the Governor’s Office of Small, Minority & Women Business Affairs. The contract is an Indefinite Quantity agreement with Fixed Unit Prices for a one-year base period, with a total award ceiling of $50,000. The scope of work includes regular inspections, preventive maintenance, and repairs for refrigeration, freezer, cooking, sanitation, ventilation, and ice machine equipment in the facility's main dietary kitchens. Contractors must address minor issues within 48 business hours and adhere to strict regulatory standards, including those from the Joint Commission on Hospital Accreditation, CMS, and NFPA 96. To be eligible, bidders must be registered with the State Department of Assessments and Taxation and hold a valid Maryland HVACR license. Because the work is performed at a secure psychiatric facility, contractors must comply with rigorous safety and security protocols, including tool inventory tracking, mandatory company ID badges, and strict patient confidentiality requirements. Bids must be submitted exclusively via eMaryland Market Place Advantage by November 4, 2026, and must include a completed bid form, a transmittal letter, and three professional references. Award will be granted to the responsible bidder offering the most favorable bid price.
Clifton T. Perkins Hospital Center

POSTED

about 15 hours ago

DEADLINE

in 5 days

General Info

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

Clarksburg VA Medical Center 1 Medical Center Drive, WV Clarksburg WV, MD, 26301

Set-Aside

NONE

Documents

1

36C24522Q0941.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Presolicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
Contacts1 person available
OfficeLINTHICUM, MD, 21090, USA
Office AddressLINTHICUM, MD, 21090, USA

Full Description

Show more
RFI SOURCES SOUGHT DISCLAIMER: This Sources Sought is issued solely for information and planning purposes and does not constitute a solicitation. Neither unsolicited proposals nor any other kind of offers will be considered in response to this Sources Sought. Responses to this notice are not offers and will not be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this Sources Sought. All information received in response to this RFI that is marked Proprietary will be handled accordingly. Responses to the Sources Sought will not be returned. At this time, questions concerning the composition and requirements for a future Request for Quote will not be entertained. SUBJECT: The Department of Veterans Affairs is conducting market research in order to provide Emergency Generator Service Contract. OBJECTIVE: See attachment. RESPONSE INSTRUCTIONS: Name and Address of Company Any small business designation as certified by the Small Business Administration A thorough description of experience in managing support requirements of this nature. CONTACT INFORMATION: Any questions related to this Sources Sought shall be directed to Mark Smith at contact@example.gov information regarding Capabilities Statements or any other proprietary information relative to this Sources Sought shall be submitted via email to contact@example.gov GENERAL INFORMATION The Louis A. Johnson VA Medical Center, Clarksburg WV requires professional services and contractor cost proposals to perform semi-annual and annual preventive maintenance and servicing of the facility s emergency generator system over a base and four optional year contract term. PROJECT REQUIREMENTS DESCRIPTION OF EQUIPMENT: GENSET #1 GENSET #2 GENSET #3 Manufacturer/Make/Year: Caterpillar Caterpillar Kato Model No: SR-4 C32 500SS9D Serial/Order No: 6NA01031 G1G00044 7319 Load Rating: (Emergency/Standby/Prime) 1000 kva 1250 kva 625KVA Power Factor: .8 .8 .8 Frequency: 60 Hertz 60 Hertz 60 hertz Load in Amperage: 1000 amps 1000 amps 87 Output Voltage: 480 480 volts 4160 volts Phase: 3-phase 3-phase 3-phase Building: Bld 17 Bld 17 Bld 17 Location (Area/Room): Generator room Generator Rm Generator Rm GENSET #4 GENSET #5 (portable) Manufacturer/Make/Year: Kohler Baldor Model No: 100RE0ZJF TS225-3J Serial/Order No: 3346GMJL0001 P1205240012 Load Rating: (Emergency/Standby/Prime) 128 kva 225 kva Power Factor: .8 .8 Frequency: 60 Hertz 60 Hertz Load in Amperage: 153 amps 625 amps Output Voltage: 480 480 volts Phase: 3-phase 3-phase Building: Parking Garage Grounds Location (Area/Room): Parking Garage Grounds (portable) GENERAL REQUIREMENTS. The Contractor, under this Scope of Work (SOW), will be responsible for labor and tools required to carry out all preventive maintenance as outlined in this SOW. All work will be carried out off hours (weekends / nights) and scheduled 10 business days prior to commencement of work. The Contractor will be required to evaluate the equipment and provide FAC with a maintenance schedule. Contractor must submit to the Contracting Officer s Representative (COR) for review, work sheet/checklist that will be used for performing maintenance service. Contractor shall provide all supervision, labor, tools, and equipment to perform Preventive Maintenance for the listed generators. All personnel working in the vicinity shall wear and /or use safety protection while all work is performed. Material Safety Data Sheets (MSDS) shall be provided by the contactor for all HAZMAT materials. Copies will be provided to the COR for approval. 3.8. Preventive maintenance for Standby generator sets to be performed by a Caterpillar ISOcertified technician or mechanic. All off site calibration of generator components to be performed by an authorized Caterpillar repair location, a calibration certificate for each calibrated component must be issued. COR must immediately be made aware of any condition discovered that could result in equipment failure. Test and inspection report shall be submitted to the COR within three days of completing work. If any discrepancies are found with the generator system that are not covered under this scope of work then the contractor must provide the following: Detailed report noting the discrepancy found. Bill of Materials (BOM) to include component name, quantity, part #, and price for any repair material required and material lead time. Price quote for repair labor. SEMI-ANNUAL CHECK (ENGINE NOT RUNNING).. Conduct visual check around the generator. Check the battery s liquids specific gravity, do battery load test, top up if necessary. Clean battery terminals and lugs. Check all V and fan belts make sure there are no hair line cracks on the belts, replace if cracked or worn. Check and adjust tension on all V and fan belts. Check coolant level and top up if necessary. Check specific gravity of coolant. Replenish as necessary to maintain manufacturers recommended level of coolant additive. Check operation and components of water jacket heating system. Test fuel day tanks for water. Record water levels in tanks. . Drain condensate from exhaust condensate trap. Clean air filter element. Inspect all fuel, oil, and water piping for secure mounting. Inspect exhaust piping and muffler insulation. Inspect crankcase breather tube. Check all control panel indication LED s. SEMI-ANNUAL CHECK (ENGINE RUNNING) Turn off the generator circuit breaker and run the generator unloaded for 15 minutes. Check the generator for unusual conditions, such as: excessive vibration, excessive black or white smoke. The following indicators on the control panel also need to be checked and varified while the generator is running: oil pressure, water temperature, rpm, voltage, and frequency. With the engine running and the generator circuit breaker open: Jumper water temperature switch Jumper oil pressure switch Jumper coolant low-level switch Press emergency stop push button. Each time the switch is jumpered or the emergency stop button is pressed the engine should stop and the corresponding failure lamp should illuminate. Reset the shut down mechanisms after each test. Start unit and run with load bank connected for 1 hour at minimum 70% load Read and record verify all engine and alternator indicators Check exhaust for excessive black or white smoke. (See manufacture s manual) Check generator bearing for noise and overheating Check exhaust manifold, muffler, and piping for leaks and secure mountings Check fuel day tank for overheating Check exhaust backpressure at Diesel particle filter (Dpf.), if above 24 In.H20 / 6 kPa , Dpf filters to be removed and cleaned. SEMI-ANNUAL CHECK (ENGINE STOPPED AFTER RUNNING) Inspect engine water, fuel, and oil systems for leaks while engine is hot. Fill out maintenance checklist and report deficiencies. ANNUAL CHECK (ENGINE NOT RUNNING) Perform complete semi-annual engine not running schedule (Section 4). Change fuel filters every 250hrs or once a year whichever is sooner Change coolant filters every 250hrs or once a year whichever is sooner Inspect battery charging Alternator and V belt. Inspect engine and generator wiring harness for wear and damages. Inspect supports and spring isolators for soundness and stability. Inspect unit thoroughly for loose fasteners. Clean radiator air passages and exhaust air ducts. Clean intake louvers and ducts. Inspect unit for corrosion. Remove any corrosion, prime and paint. Inspect fan drive idler pivot arm assembly and shock absorber Inspect Belt driven fan hub Take fuel oil samples and analyze ANNUAL CHECK (ENGINE RUNNING). Perform complete semi-annual Engine running schedule (Section 5). ANNUAL CHECK (ENGINE STOPPED AFTER RUNNING). Perform complete semi-annual Engine stopped after running schedule. (Section 6). Change crankcase oil and filters every 250 hrs or once a year whichever is sooner. Fill out maintenance checklist and report deficiencies. END SCOPE OF WORK

More opportunities from Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)

Same awarding agency

NAICS: 541330
New
Federal
C1DA--VISN 1 - INDEFINITE DELIVERY INDEFINITE QUANTITY ARCHITECT CONTRACT (Legacy VISN 5)
Solicitation # 36C24526R0107
The Department of Veterans Affairs, Network Contracting Office 5, is seeking an Indefinite Delivery Indefinite Quantity Architect and Engineering contract to provide ongoing engineering services for medical facilities and community based clinics within Legacy VISN 5, covering Maryland, West Virginia, and Washington D.C. This procurement is a total set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS 541330, with a small business size standard of 25.5 million dollars. The overall contract value is not to exceed 450 million dollars over a ten year period. Work will be executed through firm fixed price task orders competed among awardees, with individual task order values ranging from a minimum of 2,500 dollars to a maximum of 2 million dollars. The anticipated solicitation date has been revised to late December 2026 or early January 2027, with a current response deadline listed as January 8, 2027. Prospective offerors must be registered in the System for Award Management and verified in the VetBiz Registry to be eligible for award. Interested parties are explicitly instructed not to submit SF330s during this pre-solicitation phase, as the current notices are for informational purposes only. All inquiries regarding this requirement should be directed via email to the contracting officer, Liana J Holland.
Engineering Services

POSTED

about 22 hours ago

DEADLINE

in 2 months
View Details
NAICS: 513210
New
Federal
7A21--CVI 42 Evolve Tier 1 License Subscription
Solicitation # 36C24527Q0045
The Department of Veterans Affairs, through the VA Maryland Health Care System, is soliciting a contract for CVI Evolve Tier 1 software licenses and support for the Cardiology department at the Washington DC VA Medical Center. The contractor is responsible for providing all necessary software licenses, parts, materials, labor, and training required to implement, maintain, and upgrade the system. The scope specifically includes two seats of the CVI 42 Evolve Tier 1 Subscription, covering advanced reporting and specialized modules such as 4D Flow, Aortic Valve, Cardiac MR, Circle Plaque, Core CT, Mitral Valve, Quantitative Perfusion, and Strain. The contract is structured with a base year running from January 1, 2027, to December 31, 2027, and four subsequent one-year option periods, extending the total potential duration to five years through December 31, 2031. Award will be granted to the responsible offeror whose proposal is most advantageous to the government, considering price and technical factors. Key requirements for offerors include providing a manufacturer's letter of authorization, detailed OEM implementation and training plans, and justification of compatibility with existing cardiovascular equipment. Administrative requirements specify that payments will be made in arrears upon receipt of a properly prepared invoice containing the contract and purchase order numbers, as well as the equipment serial numbers and model names. The contractor must comply with Buy American certifications, OSHA safety regulations, and Controlled Unclassified Information (CUI) protocols. Performance will take place at the Washington DC VA Medical Center, with the government retaining the right to inspect and test all services and supplies prior to acceptance.
Software Publishers

POSTED

about 22 hours ago

DEADLINE

in 6 days
View Details
NAICS: 561210
New
Federal
J044--NOTICE OF INTENT TO SOLE SOURCE Baltimore VAMC Steam System Preventive Maintenance from Vicinity Energy Baltimore Corporation
Solicitation # 36C24527Q0048
The Department of Veterans Affairs is issuing a Notice of Intent to Sole Source for an open market award to Vicinity Energy Baltimore Corporation to provide annual steam system preventive maintenance at the Baltimore VA Medical Center. This requirement, classified under NAICS code 561210 and PSC J044, is driven by the fact that the facility's steam equipment is directly connected to the district steam distribution system owned and operated by Vicinity Energy. Due to this interconnected configuration and the proprietary operational data involved, the government identifies Vicinity Energy as the sole source capable of ensuring the reliable operation of the system without risking the broader distribution network. The scope of work requires a two-person crew to provide eight hours of service every two weeks, totaling 416 labor hours per year. Key responsibilities include steam trap surveys, cleaning pressure-reducing valves, inspecting heat exchangers, and ensuring proper water chemistry and meter operation. The contractor must supply all necessary parts meeting original manufacturer specifications and provide emergency call-back services with a technician on-site within five hours of notification. The anticipated period of performance is one year from the award date, with the possibility of option-year extensions. Interested vendors may submit capability statements to Contract Specialist Patricia Thai by 11:00 AM EST on November 10, 2026, referencing announcement number 36C24527Q0048. These submissions will be used solely to determine if the procurement will be conducted on a competitive basis. All work will be performed at the Baltimore VAMC, adhering to strict VA security, safety, and infection control requirements.
Facilities Support Services

POSTED

2 days ago

DEADLINE

in 11 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS