Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Defense was posted on September 19, 2005. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

36--Storage Tank, Solvent Tanks, Hazmat Storage Sheds

Awarded
W912DW-05-Q-0147Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

Contract Value

$95,358

NAICS

332312 - Fabricated Structural Metal Manufacturing

Place of Performance

WA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Combined Synopsis

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W071 Endist Seattle
ContactsNo contacts available
OfficeSEATTLE, WA, 98134-2329, USA
Office AddressSEATTLE, WA, 98134-2329, USA
ContactsNo contact information available

Full Description

Show more
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 5 EACH ______________ ___________________ WASTE OIL TANKSFFPWILL CONSIST OF ONE TANK, ONE PUMP AND TWO PORTABLE CARTS IN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS.PURCHASE REQUEST NUMBER: W68MD9-5229-3310. NET AMT ___________________ ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0002 18 EACH ______________ ___________________ SOLVENT TANKS (Parts Washers) CLAUS MODEL OR INLAND MODEL TANK SYSTEMFFPIN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS.8 TANKS WILL BE USED FOR WEAPONS CLEANERSPURCHASE REQUEST NUMBER: W68MD9-5229-3310. NET AMT ___________________ ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0003 8 EACH ______________ ___________________ HAZARDOUS MATERIAL STORAGE SHEDSFFPIN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS.PURCHASE REQUEST NUMBER: W68MD9-5229-3310. NET AMT ___________________ DELIVERY IS REQUIRED AS SOON AS POSSIBLE, WITH YOU QUOTE PLEASE SUBMIT DELIVERY DATE. ALL ITEMS ARE TO BE DELIVER TO THE ADDRESS LISTED BELOW: US Army Building 1210 Mann Avenue (Dupont Gate) Fort Lewis, WA 98433 Specifications for Used Oil Tanks Fort Lewis used oil tanks must conform to the following: 1. UL-142 listed Double walled horizontal above ground steel tank, no taller than 48. 2. 500 gallon minimum capacity. 3. Polyurethane exterior paint finish, Tan or White 4. Primary working vent device 5. Primary tank emergency vent device. 6. UL-listed 1 air operated double diaphragm pump, pump is to be mounted on top of tank. (Pump to be plumbed into the tank with flexible hose of appropriate size). 7. 8 x 1 product suction hose, with quick disconnect Dixon or Parker brand 1-female end on end of hose, and 2-male ends to be mounted by customer. 8. Air filter/ regulator with pressure gage. 9. Automatic high level shut off device 10. Tank gage (preferably a Scully type gage) 11. Manual air inlet shut off with 25 of 3/8 air hose. 12. 2 suction tube with Kamlock & dust cover for product withdrawal. 13. Appropriate Product decals 14. Please include freight to Ft. Lewis WA 98433 Activity POC: Bill Brabender, +1 (555) 000-0000. Specifications for Oil tote/caddie Specification Sheet Fort Lewis Waste oil evacuation totes/caddies must be of a John Dow Industries model and conform to the following: 1. Made of a heavy gage metal (No poly or plastic type material). 2. Tote must be able to be emptied by gravity, evacuation pump and pressurized air evac system. 3. No specification on color, but must be painted to resist rust. 4. Must be of a low profile design no higher than 10 5. 17-25 gallon capacity. 6. Must be able to have a 1 dry break fitting Parker or Dixon Type for connection to waste oil pump located on other tank. 7. Casters must be large soft rubber type, 4 or 6 in diameter. Front wheels should be of a swivel type for steering purposes. 8. Pull handle must a min. of 36 long, made from metal. 9. Must have some type of screen mesh to keep large items out of the oil tote/caddie 10. Please include freight to Ft. Lewis WA 98433 Specifications for Parts Washers Fort Lewis Parts washing tanks must conform to the following: 1. Must use/hold less than 30 gallons of solvent. 2. Must be compatible with Mil Spec PRF-680 type II solvent. 3. Must have four legs or support stands. (No drums) 4. Must have at least a one year warranty. 5. Must incorporate a work light. 6. Must have a flow through brush system and nozzle for delivering solvent in the tank. 7. Should have a large enough work basin to receive heavy duty truck parts 8. 110 VAC electric motor. 9. Some solvent tanks are purchased with solvent and filter packages. We do not recommend purchasing these items due to the approval process for solvent and we keep filters in stock for the tanks. 10. Please include freight to Ft. Lewis WA 98433 NOTE: Here on Ft. Lewis we use only the Claus model or inland model tank system. This is due to the requirement for filters and overhead for repair parts. Specifications for Outdoor Chemical Storage Lockers Fort Lewis HAZMAT sheds must conform to the following: 1. Dimensions- 7 wide, 8 tall, 5 deep 2. Color- Chemical/corrosive/ultraviolet resistant paint exterior paint finish Blue or Tan 3. One door in front, No ramp 4. NFPA 704 decals with numbers 5. Shelves for storing Hazardous material. 6. Removable steel safety floor planking 7. Forklift channels for easy mobility 8. Designed IAW standards set by NFPA Code 30 and comply with OSHA and EPA regulations 9. FM Approved for the storing of flammable and combustible liquids 10. Prefer Double walled construction to prevent condensation. 11. Inlet vents for ventilation 12. Three point locking mechanism all locks keyed the same. 11. Please include freight to Ft. Lewis WA 98433 ued.

More opportunities from Department Of Defense → W071 Endist Seattle

Same awarding agency

NAICS: 236220
New
Federal
JOINT BASE LEWIS MCCHORD MULTI DOMAIN TASK FORCE BUILDINGS 3223-3224, WASHINGTON
Solicitation # W912DW27RA014
Solicitation W912DW27RA014 is a firm fixed price construction project issued by the U.S. Army Corps of Engineers, Seattle District, for the renovation and conversion of two 1950s-era barracks facilities at Joint Base Lewis-McChord, Washington. The project involves approximately 63,400 square feet of combined work to support the First Multi-Domain Task Force Battalion. Building 3224 will be converted into a Brigade Support Battalion facility featuring a Battalion HQ and company operations space, while Building 3223 will become a combined administration, readiness, and troop aid facility. The scope of work includes site preparation, demolition, site utilities, roadways, asbestos and lead-based paint abatement, and comprehensive telecommunications installations. This is a total small business set-aside with a mandatory performance period of 730 calendar days from the date of the Notice to Proceed. Award will be determined based on a Best Value Tradeoff, where non-price factors, including past performance and a project narrative with a summary schedule, are significantly more important than price. Bidders must provide a bid guarantee and adhere to Davis-Bacon Act wage standards. Key deliverables include as-built drawings and operation and maintenance manuals, with all work required to meet government facility criteria for energy efficiency and life cycle cost-effectiveness.
Commercial and Institutional Building Construction

POSTED

1 day ago

DEADLINE

in about 1 month
View Details
NAICS: 236220
New
Federal
Design and construct an Air Traffic Control Tower at Mountain Home Air Force Base ID
Solicitation # W912DW27R1BWMSS
The U.S. Army Corps of Engineers, Seattle District, is conducting market research via a sources sought notice for the design and construction of an Air Traffic Control Tower at Mountain Home Air Force Base in Idaho. The project has a budgeted amount of 32 million dollars and an estimated period of performance of 730 calendar days. The facility must include a control cab accommodating at least six controller stations and five trainers, as well as support spaces such as a simulator room, offices, administrative areas, training and break rooms, and electronic equipment rooms. The government intends to utilize a Progressive Design Build approach with Other Transaction Authority, employing a qualifications-based selection process. This will involve an initial screening to shortlist three firms, followed by interactive pitch meetings to evaluate technical approaches and collaborative capabilities. The procurement will be split into two phases: Phase 1 focusing on the design agreement and Phase 2 focusing on final design and construction under a Guaranteed Maximum Price. Interested firms must submit a capabilities package of no more than 10 pages, including CAGE codes, UEI numbers, and bonding information, to the designated points of contact by the specified deadline.
Commercial and Institutional Building Construction

POSTED

2 days ago

DEADLINE

in 13 days
View Details
NAICS: 236220
New
Federal
Joint Base Lewis McChord (JBLM) Multi Domain Task Force (MDTF) Buildings (BLDGs) 3221 and 3222
Solicitation # W912DW27RA017
The USACE Seattle District is conducting market research via a special notice and survey to determine the feasibility of a Project Labor Agreement for the conversion of two barracks buildings, known as the Hammer Heads, into operational facilities for three tier levels of command at Joint Base Lewis McChord, Washington. This project, identified as Buildings 3221-3222 for the Multi Domain Task Force, has an estimated construction magnitude between 40 million and 70 million dollars and an expected duration of 730 calendar days. The effort is currently a small business set-aside. The scope of work involves extensive demolition and renovation, including hazardous material and debris abatement in crawl spaces, the removal of approximately 75 percent of the exterior envelope and interior walls, and the removal of 90 percent of existing mechanical and electrical systems. Required new work includes the installation of a new exterior envelope, updated mechanical and electrical systems, a new Thermoplastic Polyolefin roof system, and exterior painting. The project will also require coordination of new utility connections and management of shared construction boundaries with adjacent projects. This current notice is for survey purposes only and does not constitute a formal solicitation for proposals.
Commercial and Institutional Building Construction

POSTED

2 days ago

DEADLINE

in 13 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS