Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Department Of Veterans Affairs was posted on January 9, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

4120 MRI Chiller Replacement - CI

Closed
36C26323Q0071Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 333415
New
Federal
4120--SPECIAL Duplex Strainer - MPLS
Solicitation # 36C26327Q0054
Solicitation 36C26327Q0054 is an accelerated request for quotes issued by the Department of Veterans Affairs Network Contracting Office 23 for the supply and delivery of a brand name or equal Keckley duplex strainer and gasket for the Minneapolis VA Health Care System. This is a small business set-aside conducted under FAR Part 12 for commercial products, utilizing NAICS code 333415. The government intends to award one firm fixed price contract for one 20 inch Keckley Basket Strainer 150 RF Duplex assembly and one O-ring gasket. All items must be new and unused, featuring a modular design with sections not exceeding 2,000 pounds, carbon steel shell construction, and a one year warranty covering defects in materials and workmanship. The period of performance is from November 9, 2026, to March 15, 2027, with all deliverables due at the Minneapolis facility by the end date. Delivery is required FOB Destination, and the contract price must include all equipment, accessories, and shipping charges. Prospective offerors must be registered in the System for Award Management and the SBA Small Business Search database. Quotes must be submitted via email to the contract specialist by 10:00 AM on October 30, 2026. Submissions must include a Buy American Certificate of Origin and details regarding the manufacturer's socioeconomic category.
Network Contract Office 23 (36C263)

POSTED

about 19 hours ago

DEADLINE

in 9 days
NAICS: 333415
New
DIBBS
COOLING COIL, AIR, DUCT
Solicitation # SPE7M0-27-T-0178
Solicitation SPE7M0-27-T-0178 is issued by the DLA Weapons Support Maritime Supply Chain ESOC Buys for the procurement of one duct type air cooling coil, identified by NSN 4130011916131 and part number 19-80-2979M. The requirement is classified under NAICS code 333415 and is set aside for small businesses, with a specific price evaluation preference for HUBZone concerns. The original required delivery date is October 1, 2026, with a delivery window of five days after receipt of order. Delivery is FOB Origin, and both inspection and acceptance will occur at the destination, specifically the Puget Sound Naval Shipyard IMF in Bremerton, Washington. The contract mandates strict adherence to technical and quality requirements via the DLA Master List and specifies packaging and marking standards according to MIL-STD-2073-1E and MIL-STD-129. Special restrictions are in place regarding the use of mercury and the removal of government identification from non-accepted supplies. Administrative requirements include electronic invoicing through the Wide Area WorkFlow system and submission of all quotes via the DLA Internet Bid Board System by October 19, 2026. Key regulatory clauses apply, including the Buy American and Balance of Payments Program, NIST SP 800-171 assessment requirements, and safeguarding of covered defense information.
DLA WEAPONS SUPPORT MARITIME SUPPLY CHAIN ESOC BUYS

POSTED

1 day ago

DEADLINE

in 1 day
NAICS: 333415
New
DIBBS
COOLING COIL, AIR, DUCT
Solicitation # SPE7M0-27-T-0185
Solicitation SPE7M0-27-T-0185 is a request for quotations issued by the DLA Weapons Support Maritime Supply Chain ESOC Buys for the procurement of one duct type air cooling coil, identified by NSN 4130-01-257-9076. The requirement specifies part number 19-80-2612M1, associated with Edge Electronics Corporation and Electric Boat Corporation. Delivery is required within five days after order, with an original required delivery date of October 1, 2026. The item is to be delivered FOB Origin to the Puget Sound Naval Shipyard IMF in Bremerton, Washington, using the fastest traceable means, specifically prohibiting the use of parcel post. The contract mandates strict adherence to MIL-STD-2073-1E for packaging and MIL-STD-129 for marking, with a general requirement to avoid plastics for wrapping or cushioning. Technical and quality standards are governed by the DLA Master List, though it is noted that no approved Technical Data Package is currently available for this NSN. Material restrictions prohibit the intentional addition of mercury, and the use of additive manufacturing is forbidden unless specifically authorized. Compliance with the Buy American Act, Berry Amendment, and NIST SP 800-171 cybersecurity standards is required. Inspection and acceptance will occur at the destination, and all invoicing must be processed electronically through the Wide Area Workflow system.
DLA WEAPONS SUPPORT MARITIME SUPPLY CHAIN ESOC BUYS

POSTED

1 day ago

DEADLINE

in 1 day

General Info

NAICS

333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

Place of Performance

Des Moines, IA, 50310, USA

Set-Aside

NONE

Documents

1

36C26323Q0071.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhaseClosed
Posted

Solicitation

Notice updated

The notice title changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → Network Contract Office 23 (36C263)
Contacts2 people available
OfficeSaint Paul, MN, 55101, USA
Office AddressSaint Paul, MN, 55101, USA
Contacts
Terry McAllister
Timothy Kimmel

Full Description

Show more
STATEMENT OF WORK THIS IS A BRAND NAME OR EQUAL REQUIREMENT FOR CARRIER BRAND EQUIPMENT AND SUPPLIES SCOPE: Engineering has a need to replace the Chiller which supplies chilled water to the air handler and air conditioner for the MRI room and MRI mechanical room in building 1. The chiller has been having many issues and it has R-22 refrigerant in it which is being phased out by the EPA. Because of the many issues and the R22 it has a high risk of possible failure and is a possible environmental hazard. If the chiller would fail it would leave the MRI without cooling for direct patient care and the MRI equipment. The Chiller is located outside on the east side of the MRI building at the Des Moines, IA VACIHCS. All work will be performed during after normal hours and or on the weekend and must be coordinated with the COR at a minimum of 60 days prior to the start date to allow VA staff to prepare for the electrical outage. Each transformer will be replaced on separate days. MINIMUM REQUIREMENTS: - 15 tons cooling with Air Cooled Condenser - 460 - 3 - 60 HZ power supply - XL Starter Type - 30% Propylene Glycol - Single Point Power with Terminal block - Low Sound - Includes Aero-Acoustic Fans - MCHX Condenser coil - Standard Packaging - Cooler Heater - Standard Compressor with Std SCCR (5k) - Green Speed Intelligence - High Efficiency Variable Condenser Fan - Hail Guards / Security Grilles - BACnet Communications - Wind Baffle Services to be performed by the Contractor. 1. Complete a pre removal inspection/test of existing equipment. 2. Supply the chiller, all parts, materials, and supplies needed and transport to the work site. 3. Coordinate with the COR to shut down the MRI Chiller and Imaging staff. 4. Isolate and disconnect the chiller water lines/piping. 5. Isolate and disconnect/remove all power sources. 6. Remove the old Chiller and dispose of it at no additional cost to the Government. 7. Reconnect the chiller water lines/piping. 8. Insulate piping 9. Reconnect all power sources. Install new external electrical disconnect switch - 60 Amp- NEMA 4) 10. Ensure controls wires are installed. 11. Preform the factory startup. 12. Test for proper operation and inform COR when work has been completed. 13. Provide training for the new chiller operation. 14. Provide the COR with copies of the owner/operator manuals and warranty documentation/items. 15. Rigging and lifting devices needed to lift the chillers will be provided by the contractor. 16. The Contractor will provide and use proper personnel barricades during use of lifting equipment. Emergency Services: Contractor shall respond immediately to the COR after identification of an emergent problem or damage that may occur during the removal or installation of the fore mentioned equipment. Under these conditions of equipment failure, the Contractor shall be required to perform necessary and immediate repairs to the area at no cost to the Government and will be expected to continue work until the repairs are made and the equipment is fully operational. Clean up: The Contractor at the end of each workday shall thoroughly clean the work area, removing all dirt, debris and waste that accumulate because of the services performed. All hazardous waste resulting from the repairs will be removed and properly disposed of in accordance with all State, Local, and Federal regulations at no additional costs to the Government. It shall be the sole responsibility of the Contractor to comply with all State, Local, and Federal regulations including but not limited to maintaining any and all current State and Federal certifications.

More opportunities from Department Of Veterans Affairs → Network Contract Office 23 (36C263)

Same awarding agency

NAICS: 561710
New
Federal
R499--Sources Sought - Minneapolis VA Medical Center - Pest Control Services
Solicitation # 36C26327Q0063
The Minneapolis VA Health Care System is conducting market research through a Sources Sought Notice to identify capable vendors for Integrated Pest Management Services (IPMS) under NAICS code 561710. This is not a formal solicitation, and no contracts will be awarded from this notice. The government is seeking information to develop an acquisition strategy, including potential set-asides for Service-Disabled Veteran-Owned, Veteran-Owned, and other socio-economic small business categories. Interested parties must submit their capabilities, SAM Unique Entity ID, and responses to specific questions regarding subcontracting and government contract vehicles to Alisha Milander by October 22, 2026, at 12:00 PM Central Time. The scope of work involves comprehensive pest suppression across various buildings and grounds, including the main medical center and multiple clinics. Key requirements include the eradication of common indoor and outdoor pests, the use of convection heat treatment for bed bugs, and monthly K9 bed bug inspections. The contractor will be responsible for installing and maintaining at least 18 insect light traps, providing pigeon reduction services for Building 70, and performing annual perimeter pesticide applications. All services must comply with EPA, DOT, and OSHA regulations. The anticipated base period of performance is from December 1, 2026, to November 30, 2027.
Exterminating and Pest Control Services

POSTED

6 days ago

DEADLINE

in 1 day
View Details
NAICS: 811310
New
Federal
F109--Boot Repair for Underground Fuel Tank in Support of the Fargo VA Healthcare System, Fargo ND
Solicitation # 36C26327Q0058
The Department of Veterans Affairs Network Contracting Office 23 is seeking capable sources to perform boot replacement and hydrostatic integrity testing for underground fuel tank number 6 at the Fargo VA Health Care System in Fargo, North Dakota. The scope of work requires the contractor to provide all labor, materials, equipment, and supervision to remove deteriorated entry boots and install manufacturer-approved repair boots, while also correcting underground storage tank sump deficiencies. All work must be performed in accordance with North Dakota Department of Environmental Quality requirements, EPA, NFPA 110, and Joint Commission standards. Key deliverables include hydrostatic integrity test results, a certified final repair report, disposal records for removed equipment, and a one-year warranty on all parts and labor. This action is currently a Request for Information and Sources Sought notice, and no formal solicitation exists at this time. Interested parties must submit their company information, business size, capabilities statement, and proof of North Dakota UST contractor credentials to Joseph Bennett via email by 5:00 PM CT on Thursday, October 22, 2026. The email subject line must include RFI number 36C26327Q0058. Once awarded, the anticipated period of performance is 90 days from the Notice to Proceed, with a required completion date of November 13, 2026. Work is to be performed Monday through Friday between 8:00 AM and 4:00 PM.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

6 days ago

DEADLINE

in 1 day
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS