Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on June 30, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

4310--Medical Vacuum System

Closed
36C24221Q1098Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

Syracuse VA Medical Center 800 Irving Avenue, Syracuse, NY, 13210

Set-Aside

NONE

Documents

1
DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)
Contacts1 person available
OfficeALBANY, NY, 12208, USA
Office AddressALBANY, NY, 12208, USA
Contacts
Morgan WeekContract Specialist

Full Description

Show more
Please note that this is NOT a request for quotes or proposals, the Government is seeking information for market research purposes only. The Department of Veterans Affairs, Network Contracting Office 2 is currently conducting a market survey to locate qualified firms capable of a Medical Vacuum Package. The specifications are listed below: A. Provide a complete medical vacuum package, complying with NFPA 99 in all respects, 200 ACFM nominal capacity, 25.5 Hg maximum vacuum, duplex rotary claw type vacuum pump with an epoxy lined 200 gallon vertical receiver with mounted and wired NFPA 99 compliant Duplex PLC control panel with RTA protocol converter. System shall have duplex filters on the suction side of the pump. All components shall be factory packaged (pre-wired and pre-piped), on a steel base, or tank mounted. All package piping shall be type L or type K rigid copper. Provide discharge separator/silencer. B. All components shall be duplex and valved (or check valved as permitted NFPA 99) to allow service to any component without interrupting vacuum service to the facility during any maintenance operation or any condition of single fault failure. The design load shall be met with the largest single unit out of service. Each pump exhaust shall be isolated by a union fitting permitting capping for service removal. Receiver shall be serviceable without shutting down the medical-surgical vacuum system. C. A complete and operational plant (source equipment) shall be furnished consisting of pumps, receiver, filters, and controls capable of providing the scheduled capacity with one pump out of service. All capacities shall be indicated in SCFM at 483 mm (19 inches Hg) and 600 mm (24 inches Hg). The duplex filters on the suction side of the pumps (0.1 micron hydrophobic filter or equivalent) shall be designed to allow one filter to be replaced while maintaining operation of the vacuum system. Each filter shall be sized for 100% of the demand. Multiple filters in parallel is acceptable to meet this requirement. Each filter shall be fitted with a clear polycarbonate bowl for visual inspection with a Pressure Differential gauge and a petcock for pressure relief and a drain valve. A vacuum relief petcock shall be provided for each filter canister. In normal operation, one filter or filter bundle shall be isolated from the system to be available for service should a blockage in the operating filter occur. D. System shall be completely factory assembled, requiring only interconnection between modules on site. Systems requiring on site assembly other than interconnection are prohibited (replacement of components removed for shipping is permitted). E. Motor and Starter: Maximum 40 degrees C (104 degrees °F) ambient temperature rise, close coupled to a NEMA rated, High Efficiency, TEFC motor with a service factor of 1.15, ball bearings, for operation with 480v voltage, 3 phase, 60 Hz power. Motor shall be of such capacity that brake horsepower required by driver equipment at normal rated capacity will not exceed nameplate rating of the motor. Provide each motor with automatic, fully enclosed, magnetic starter. F. Each pump shall include inlet and outlet flex connectors supplied by the medical vacuum equipment manufacturer. G. Programmable Logic Controllers (PLC) or Direct Digital Controls (DDC) can be used to implement operating logic. Controls shall have integral memory and EPROM backup. Controls shall control the automatic alternation lead-lag of the vacuum pumps with provisions for simultaneous operation if required, and automatic activation of reserve or lag unit if required. A lag alarm on control cabinet and contacts for the master alarm shall be provided. H. The complete control system and all electrical components shall be NEMA ICS 6, Type 12 and UL labeled. The control system shall provide: 1. Automatic lead/lag sequencing including self-adjusting minimum run timers which adaptively optimize the number of pump starts based on demand. 2. Circuit breaker disconnects for each vacuum pump with external operators. Units with fuses instead of circuit breakers in motor circuit are prohibited. The control system shall include an automatic minimum run time adjustment to automatically adjust run time based on demand. 3. Full voltage motor starters with overload protection. 4. Redundant 120 volt control circuit transformers. 5. Visual and audible reserve unit alarm with isolated contacts for remote alarms and audio cancel. 6. Control cabinet shall have lighted HOA selector switches 7. Panel mounted vacuum gauge, external visual lights indicating on/off status, audible and visual signals for thermal overload, oil discharge filter differential pressure or back pressure alarm, and alarm silence button. 8. Contacts for external oil discharge filter differential pressure or back pressure alarm 9. If silence has been pressed, audible and visual signal would be reactivated upon second alarm condition. Alarm shall be reset upon correction of original signal. 10. Runtime hour-meter for each pump. I. The medical vacuum pumps shall be non-contacting claw style rotary design. The internal construction shall be friction free and require no sealants. Each medical vacuum pump shall be air-cooled and continuous duty rated. Each medical vacuum pump shall be provided with a single lubricated gearbox requiring an oil change not more often than 5,000 operating hours under light duty and 2,000 hours heavy duty. Each medical vacuum pump shall be equipped with an exhaust silencer. Each medical vacuum pump shall be equipped with a high vacuum shutdown, a high temperature shutdown, a remote alarm at the BAS and local alarms. The lubricant supplied shall be inert with oxygen and the medical vacuum pump shall be factory cleaned for oxygen service. J. Include vibration isolation pads for the floor mounting. K. The complete medical vacuum system and all electrical components shall be factory tested prior to shipment by the medical vacuum equipment manufacturer. Those capable of providing these services should submit a statement regarding their capability on a document containing the official company letterhead. Additionally, those interested and capable shall provide a designated point of contact, the business DUNS Number, and the business Socioeconomic status in their response to this posting. The North American Industry Classification Systems (NAICS) is 339113. The purpose of this notice is to gain knowledge of potential qualified sources and their size classification/ socioeconomic status (service-disabled veteran owned small business, veteran owned small business, HUB Zone, 8(a), small business or large business), relative to NAICS 399113. Responses to this notice will be used by the Government to make appropriate acquisition decisions. Responses to this notice should include company/individual name, a service capability statement, examples of similar facilities for which you have provided services to, DUNS number, address, point of contact and social-economic category (ex: SBVOSB, VOSB, 8(a), HUBZone, WOSB, EDWOSB, Small Business). If your firm is a Service-Disabled Veteran Owned or Veteran Owned Small Business, you must be VERIFIED in VetBiz (see internet site: http://vip.vetbiz.gov). Contractor must be registered in System for Award Management (SAM), (see internet site: http://www.sam.gov). Responses to this notice must be submitted in writing via email to contact@example.gov and must be received not later than July 8, 2021 by 3PM EST. No telephone inquiries will be accepted. Interested firms are encouraged to also add their information to the interested vendors list for this announcement at www.fbo.gov. Facility Address: Department of Veterans Affairs Syracuse VA Medical Center 800 Irving Ave. Syracuse, NY 13210

More opportunities from Department Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)

Same awarding agency

NAICS: 621999
New
Federal
Q525--LASER SERVICES - BUFFALO UROLOGY Holmium (30 and 80 Watt) Lasers CO2 Laser Lithotripsy (ESWL) Laser
Solicitation # 36C24227Q0105
The Department of Veterans Affairs, through Network Contracting Office 2, is conducting market research via a Request for Information for an anticipated five-year contract to provide laser services at the Buffalo VA Medical Center. The scope of work includes the provision of Holmium (30 and 80 watts), CO2, and Lithotripsy (ESWL) laser units, all necessary supplies and disposables, and New York State certified technicians. The contractor will be responsible for all labor, supervision, and equipment maintenance, ensuring all units operate according to manufacturer specifications. A critical technical requirement is that all equipment must plug directly into wall outlets without adapters or transformers, as the surgical suites are wired for 30amps and 240 volts or less. The contractor must maintain up-to-date preventative and corrective maintenance records for the Biomedical Engineering Department and complete Laser Use Records for every case. Liability for patient injury resulting from laser malfunction rests with the contractor. This effort falls under NAICS code 621999, with a small business size standard of 20.5 million dollars. Interested respondents must be registered in the System for Award Management and submit a capability statement not exceeding 12 pages by 4:00 PM Eastern Time on November 20, 2026. Responses must include detailed equipment specifications, a history of experience with the VA or other entities, and specific company identification and socioeconomic status details.
All Other Miscellaneous Ambulatory Health Care Services

POSTED

about 11 hours ago

DEADLINE

in 21 days
View Details
NAICS: 621511
New
Federal
Q301--Reference and Esoteric Laboratory Testing
Solicitation # 36C24227R0003
The Department of Veterans Affairs, Network Contracting Office 2, on behalf of Veterans Integrated Service Network 2 South, intends to award an unrestricted requirements contract for comprehensive Reference Laboratory and Esoteric Testing Services. This procurement, categorized under NAICS 621511, will support several facilities including the James J. Peters, Northport, and New York Harbor VA Medical Centers, as well as the VA New Jersey and Hudson Valley Healthcare Systems. The selected contractor will be responsible for providing all necessary personnel, equipment, and supervision to perform laboratory analysis, including the routine and STAT transportation of specimens, pre-analytic processing, and the provision of all required collection and preservation consumables. Key technical requirements include maintaining a direct system interface with the VA VistA Laboratory Information System for the timely electronic reporting of results. The contractor must also provide professional consultation on test selection and result interpretation while ensuring strict compliance with HIPAA and VA information security standards and maintaining all necessary industry certifications and accreditations. This is currently a pre-solicitation notice for informational purposes; no proposals are being accepted at this time. The formal Request for Proposal is expected to be posted on SAM.gov under notice number 36C24227R0003 on or about October 7, 2026.
Medical Laboratories

POSTED

about 11 hours ago

DEADLINE

in about 1 month
View Details
NAICS: 811210
New
Federal
J065--FY27 SERVICES (BASE+4) - Canon CT Service Contract
Solicitation # 36C24227Q0076
Solicitation 36C24227Q0076 was a firm-fixed-price request for quote issued by the Department of Veterans Affairs, Network Contracting Office 2, for the annual preventative maintenance and repair of two Canon/Toshiba Aquilion Prime 160 CT machines located at the Buffalo VA Medical Center. The requirement was set aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 811210. The proposed contract structure consisted of a base period from November 1, 2026, to October 31, 2027, with four subsequent option years. The scope of work required preventative maintenance to be performed four times per year, a 30-minute telephone response time for corrective repairs, and an on-site engineer response time of 4 to 6 hours. The government intended to award the contract to a responsible offeror based on a comparative evaluation of technical capabilities, past performance, and price. Contractors were required to provide all labor and parts, with new parts warranted for 12 months. Compliance requirements included adherence to manufacturer specifications, patient information confidentiality, and the maintenance of commercial general liability insurance. Despite the detailed solicitation and subsequent amendments to extend the submission deadline to October 28, 2026, the solicitation is now closed with no award made.
Electronic and Precision Equipment Repair and Maintenance

POSTED

about 11 hours ago

DEADLINE

in 3 days
View Details
NAICS: 238110
New
Federal
Z2NZ--Manhole Repairs at Montrose VAMC
Solicitation # 36C24227R0012
The Department of Veterans Affairs, Network Contracting Office 2, intends to solicit construction services for the rehabilitation and repair of two underground utility manholes at the Montrose VA Medical Center in Montrose, New York. This project, identified by solicitation number 36C24227R0012, aims to restore structural integrity, prevent water infiltration, and ensure safe vehicular access. The scope of work includes the demolition and replacement of damaged concrete lids and frames, localized excavation, installation of reinforcing steel, waterproofing, corrosion protection, adjustment of manhole elevations, and the restoration of surrounding asphalt surfaces. The contractor is responsible for providing all labor, materials, equipment, and supervision, including water removal, traffic control, site preparation, testing, and final cleanup. This procurement is anticipated as a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 238110, which has a small business size standard of 19.0 million dollars. The estimated magnitude of construction is between 25,000 and 100,000 dollars. The period of performance is 60 calendar days from the Notice to Proceed, including 10 days for contractor closeout. Eligible offerors must be registered and verified as an SDVOSB in SAM.gov and Duns and Bradstreet at the time of submission. The official solicitation was anticipated for release on October 30, 2026, via SAM.gov.
Poured Concrete Foundation and Structure Contractors

POSTED

about 11 hours ago

DEADLINE

in 12 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS