Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

4320--Condensate Receiver

Active
36C24227Q0088Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

NAICS

333914 - Measuring, Dispensing, and Other Pumping Equipment Manufacturing

Place of Performance

NY

Set-Aside

NONE

Documents

1

36C24227Q0088.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseSources Sought
Posted

Sources Sought

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)
Contacts1 person available
OfficeALBANY, NY, 12208, USA
Office AddressALBANY, NY, 12208, USA
Contacts
LaTriece BruceContract Specialist

Full Description

Show more
1.0 DISCLAIMER This Request for Information (RFI) is issued in accordance with the RFO FAR 10.001 to determine the availability and technical capabilities of qualified sources. Please respond to the questions in section 3.0. The associated North American Industrial Classification System (NAICS) code for this procurement is 333914, Measuring, Dispensing, and Other Pumping Equipment Manufacturing, with a small business size standard of 750 employees. The RFO FAR Provision found at 52.204-7(b)(1) requires that all offerors obtain a UEI to register in SAM. You may access the SAM website at https://www.sam.gov/portal/public/SAM/. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified by the Small Business Administration at the time of quote submission. This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This RFI is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. 2.0 DESCRIPTION OF ANTICIPATED NEED The Buffalo VA Medical Center is seeking to replace its Domestic Model 52CB45-15 Duplex Condensate Unit (15 psig rated) for integration into the existing piping, supporting facility operations. This procurement is necessary to replace an existing aging condensate receiver with a functionally identical, capacity-matched, pressure-rated unit to ensure full compatibility with current piping, controls, and operating conditions.
General Requirements 
The contractor shall furnish one (1) new Domestic 52CB45-15 Duplex Condensate Unit, factory-assembled and tested; ensure the unit includes all standard manufacturer components; and provide documentation verifying the unit is rated for 15 psig and matches the configuration needed to avoid piping modifications. 
Technical Requirements 
The supplied equipment must meet the following: Model Domestic 52CB45-15; duplex pump arrangement; tank construction matching existing inlet/outlet configuration; operating pressure rating of at least 15 psig; electrical compatibility with facility distribution; and pump performance equal to or exceeding existing needs without exceeding system limitations. 
Delivery Requirements 
The contractor shall coordinate delivery with facility engineering personnel; ensure equipment arrives fully protected; and provide manufacturer documentation including O&M manuals, warranty information, and pump curves for acceptance.  Installation Notes (By Facility or Separate Contract) 
This procurement covers equipment purchase only. All connection points on the new unit must match existing field piping interfaces to ensure installation without modifications. Contractor shall provide dimensional drawings verifying this requirement prior to shipment. 
Specs and manufacturer:
Receiver Manufacturer Model # Quantity Duplex / Type B pump design Domestic
52CB45-15 1
System shall be 45,000 Sqft EDR capacity with a discharge pressure of 10-15PSIG with a ¾ horsepower motor at 3500RPM. The discharge size shall be 1-1/2
EXCLUSIONS  This SOW does not include piping modifications, electrical work, startup or commissioning services, or disposal of the existing condensate receiver. 
PERIOD OF PERFORMANCE  Delivery shall occur within 30 calendar days after receipt of an approved purchase order, unless otherwise coordinated. 
WARRANTY  The manufacturer s standard twenty-year minimum warranty applies, covering defects in materials and workmanship. Contractors must be available and on site for any warranty work within 24hours of first contact. This is a critical piece of equipment responsible for the life and safety of laboratory animals.
DELIVERY REQUIREMENTS
All items must be delivered to the Buffalo VA Medical Center 3495 Bailey Avenue, Buffalo, NY 14215.
The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the Government that the interested parties can provide the supplies/services that fulfill the required specifications mentioned above. 3.0 QUESTIONS Business Size: Type of Business of Prime Contractor (Check all applicable boxes) Large Business   Small Business (Check type of Small Business Below, if applicable)     Small Disadvantaged Business (SBA Certified)   Women-Owned Small Business   HUB Zone Small Business (SBA Certified)   Veteran Owned Small Business     Serviced Disabled Veteran Owned Small Business     8(a) Small Business (SBA Certified)  
Does your company maintain any Schedule Contracts (e.g., GSA, GWAC etc.)? Is this item on your contract? If so, list where the required supplies are offered (please provide the contract number, expiration date, and Government point of contact).
Does your company have the ability to provide the equipment listed under the 2.0 DESCRIPTION OF ANTICIPATED NEED section above?
Are you a manufacturer or authorized distributor of this equipment?
What country were the products manufactured in? Note, we are seeking domestic sources.
Please provide a capability statement that includes your SAM.gov UEI number.
Responses are due via email to contact@example.gov by 12:00 PM Eastern Standard Time (EST) November 1, 2026. DISCLAIMER: This Source Sought/RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this Source/Sought RFI. The Government is not obligated to provide comments to vendor submissions.

Similar Contracts

Same NAICS industry code

NAICS: 333914
New
Federal
PUMP,RECIPROCATING
Solicitation # SPRPA126QYD35
Solicitation SPRPA126QYD35, issued by DLA Aviation at Philadelphia, is a small business set-aside for the procurement of newly manufactured reciprocating pumps. This item is designated as critical material because it is used in shipboard systems for aircraft launch and recovery, where failure could lead to serious injury or loss of life. Consequently, the government requires that all supplies be newly manufactured, as refurbished or repaired materials are ineligible for award. Offerors must be government-approved sources of supply, and distributors must provide an authorized distributor letter on the source's letterhead at the time of proposal submission. The contract is a fixed-price agreement requiring adherence to AS/EN/JISQ 9100 quality standards and NAWCAD Lakehurst drawing 80020 / 653D326-1. Delivery is required within 90 days, with inspection and acceptance occurring at the origin. Packaging must comply with MIL-STD-2073-1 and MIL-STD-129 marking requirements. Award will be made to a single responsible offeror based on the most advantageous combination of price and past performance, with past performance weighted as more important. Evaluation will include risk assessments via the Supplier Performance Risk System regarding item, price, and supplier risk. Invoicing and receiving reports must be processed through Wide Area Workflow.
Pa DLA Aviation At Philadelphia

POSTED

about 9 hours ago

DEADLINE

in 6 days
View Details

More opportunities from Department Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)

Same awarding agency

NAICS: 811210
New
Federal
J065--FY27 SERVICES (BASE+4) - Canon CT Service Contract
Solicitation # 36C24227Q0076
Solicitation 36C24227Q0076 is a firm-fixed-price request for quote issued by the Department of Veterans Affairs for the annual preventative maintenance and repair of two Canon/Toshiba Aquilion Prime 160 CT machines at the Buffalo VA Medical Center. This SDVOSB set-aside contract, falling under NAICS 811210, covers a base period from November 1, 2026, through October 31, 2027, with four subsequent one-year option periods. The scope of work requires preventative maintenance to be performed four times per year and includes all corrective maintenance labor and replacement parts, including X-ray tubes. The contractor must adhere to manufacturer specifications and meet strict response times, including a 30-minute telephone response and an on-site engineer arrival within 4 to 6 hours for repairs. The government will award the contract to the responsible offeror deemed most advantageous based on a comparative evaluation of technical capabilities, past performance, and price. Key requirements include maintaining commercial general liability insurance, complying with patient confidentiality and information security regulations, and providing electronic field service reports within five days of repair completion. All replacement parts must carry a 12-month warranty. While the contractor is responsible for maintenance, it is confirmed that a network firewall already exists between the CT scanners and the hospital network. Quotes must be submitted by October 27, 2026, and must include the offeror's Unique Entity Identifier and a statement of agreement with all solicitation terms.
Electronic and Precision Equipment Repair and Maintenance

POSTED

about 9 hours ago

DEADLINE

in about 21 hours
View Details
NAICS: 339113
New
Federal
6515--Smart Hospital Stretchers for the ambulatory procedural unit at the Hudson Valley, Castle Point VAMC.
Solicitation # 36C24227Q0090
The Department of Veterans Affairs, VISN 02 Network Contracting Office, has issued a Sources Sought Notice to identify qualified providers for five smart hospital stretchers for the ambulatory procedural unit at the Hudson Valley, Castle Point VAMC. This notice is intended for market research and planning purposes only and does not constitute a formal solicitation. The required stretchers must be designed for fall prevention, patient comfort, and clinician support across emergency, perioperative, and transport settings. Key technical specifications include a 19-inch low height, a 700 lb safe working load, a three-mode bed-exit system with visual indicators, and integration capabilities for Voalte Nurse Call and EMR systems. The selected contractor will be required to deliver the equipment within 30 days of award and provide a three-year warranty covering on-site repairs and preventive maintenance by certified technicians. Interested sources must respond by November 2, 2026, providing their Sam.gov Unique Entity ID, business size status under NAICS code 339113, and details regarding their role as a manufacturer or distributor. Additionally, respondents must disclose any existing GSA, NAC, or NASA SEWP contracts and specify whether the products are manufactured domestically in the United States.
Surgical Appliance and Supplies Manufacturing

POSTED

about 9 hours ago

DEADLINE

in 6 days
View Details
NAICS: 334516
New
Federal
6640--Electrophoresis Testing for the Albany, Buffalo, and Syracuse VA Medical Centers
Solicitation # 36C24226Q0949
The Department of Veterans Affairs, Network Contracting Office 2, is soliciting quotations for a five-year Indefinite Delivery/Indefinite Quantity (IDIQ) firm-fixed-price contract to provide a fully automated, FDA-approved multi-parameter agarose gel electrophoresis analysis system. This system will support the Albany, Buffalo, and Syracuse VA Medical Centers, with an estimated annual volume of 5,100 patient test results covering SPEP, UPEP, IFE, and CSF/Oligoclonal testing. The estimated ordering period runs from November 1, 2026, through October 31, 2031, with a guaranteed minimum contract value of 10,000 dollars. Interested vendors must submit a complete technical response addressing the Statement of Work, pricing aligned with the established CLIN structure, and a detailed implementation plan for installation within 90 days of award. Required documentation includes VA Directive 6550 Appendix A and the Manufacturer Disclosure Statement for Medical Device Security. The government will use a comparative evaluation process under FAR 12.203(c)(2), offering price credits to SDVOSBs (10%) and VOSBs (5%), as well as credits for those utilizing veteran-owned subcontractors. Following Amendment 0002, the submission deadline has been extended to November 2, 2026, at 3:00 PM EST.
Analytical Laboratory Instrument Manufacturing

POSTED

1 day ago

DEADLINE

in 6 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS