Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Government Contract opportunity was posted on July 2, 2012. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

50 GHz Power Augmentation Source

Awarded
FA2263-12-R-0009Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

Agency

N/A

Contract Value

$718,933.12

NAICS

334515 - Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals

Place of Performance

Not specified

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

2 updates
PhaseAwarded
Posted

Presolicitation

Type Changed

Presolicitation → Combined Synopsis

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts1 person available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts

Full Description

Show more
** 18 April 2012 ** A question has been asked regarding section 2.10 of the Purchase Description. Question: 2.10 Single Sideband Phase Noise. The frequency range of 100 KHz to 50 GHz with a carrier offset of 2.5E-05 * Carrier frequency (Hz) the single sideband phase noise shall not exceed -40 dBc(Hz). I believe the offset of 2.5E-05 should not have the minus sign. I believe it should read 250 KHz or 2.5 E 05 Hz. Please clarify. Response: To avoid confusion, lets change it to 250 KHz.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS