Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

51 -- 5130-00-089-3353

Active
RFQ-5130-00-089-3353Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The contract requests quotes for 179 portable electric circular saws, referencing a prior procurement price of $134.99 each for the Kipper Tool model. These saws are designed primarily for cutting wood at angles between 0 and 45 degrees but can also cut metals, masonry, and ceramic materials with specialized blades. Key specifications include a double-insulated or grounded design, a two-pole instant-release trigger switch without a lock-on feature, a universal motor operating on 120 volts AC or DC, and an electric brake that stops the blade within two seconds. The saw blades are carbide-tipped, with diameters between 7 and 7-1/4 inches, a minimum no-load speed of 5,000 RPM, cutting capacities of 2-3/8 inches at 0 degrees and 1-3/8 inches at 45 degrees, and at least half a horsepower output. Each saw must come with maintenance tools, including an arbor nut wrench, and be packaged in a durable plastic or metal carrying case. Packaging and marking must comply with federal and military standards, with unit packaging designed to protect the product during shipment and palletization requirements specifying pallet sizes, weight limits, stacking tests, and securement using stretch wrap or strapping with edge protectors. Lumber packaging must be bark-free and comply with hardwood requirements. Special instructions apply for shipments to European Union countries, with adherence to applicable international and Department of Defense regulations. The contract includes detailed provisions for stability, safety, and handling during transportation and storage to ensure the products arrive in optimal condition. For inquiries, the contact provided is Celeste R. Gorman.

General Info

Purchase of 179 Kipper Tool saws, 7-1/4 inch blades, electric brake, packaged per military standards.

Agency

N/A

NAICS

332212 - Hand and Edge Tool Manufacturing

Place of Performance

Not specified

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

special-notice

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyN/A
Contacts1 person available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts

Full Description

Show more
Request for quote. Please state your price and your very best delivery. Procurement History - Kipper Tool $134.99 5130-00-089-3353 UI: EA QTY 179 SAW, CIRCULAR, ELECTRIC, PORTABLE: DESCRIPTION This technical description covers a portable electric circular saw for use in an industrial or commercial environment. The portable, electric saw described in this technical description is hand-guided and intended primarily for crosscutting and rip-sawing wood products at angles from 0 to 45 degrees. By use of special saw blades, ferrous and nonferrous metals, masonry, and ceramic materials may also be cut. Salient Characteristics: Design and construction - The circular saw covered in this technical description and its accessories shall constitute complete and functional products. The saw shall be either double insulated or of the 3-wire grounding construction. Switch - A two-pole, single-throw, instant-release trigger switch shall be provided and mounted in the saw handle. The switch shall be provided with a guard to prevent accidental actuation. The switch shall not be equipped with a mechanism for locking in the "ON" position. Mechanism for locking in the "OFF" position is acceptable. Electrical specifications - Unless otherwise specified, the motor for the saws shall be of the universal type designed to operate on either 120 volt(+,-10%) direct current(DC), or 120 volt(+,-6%), single-phase, 25-60 cycle alternating current(AC). The motor shall be mounted integral with the saw. The motor armature shall be balanced dynamically to insure freedom from destructive vibration. Electromagnetic interference suppression - Not required Power cord and plug - The flexible cord shall be rated for use at a voltage not less than the rated voltage for the type motor as specified in the above Electrical specifications paragraph of this technical description. The saw shall be furnished with a wire supply cord with an integral ground. Unless otherwise specified the plug and cord shall have a minimum free length of 8 feet measured from point of entry into the saw. Electric brake - The saw shall be provided with an electric brake feature to reduce coasting and stop blade in a maximum of two(2) seconds. Saw Blades - Unless otherwise specified the saw shall be furnished with a carbide-tipped combination saw blade having 20 to 28 teeth. The saw shall meet the following requirements: Type I - Motor armature axis parallel to saw-blade-spindle axis. Size 7 - Blade Diameter 7 to 7-1/4 inches. No-load Blade Speed - 5000 RPM minimum. Cutting Capacity - 2-3/8 inches. Cutting Capacity: At 45 degree angle, at least - 1-3/8 inches. Power Output at Spindle - 1/2 minimum horsepower Rated Current - 13 amperes minimum Blade Arbor Hole Diameter - 5/8 inches Weight (Minus cord)- 18 pounds maximum Accessory equipment - The saw shall be supplied with such maintenance tools, accessories and extra parts as normally furnished commercially. One arbor nut wrench shall be included with each saw. Carrying case - Each saw shall be provided within a sturdy impact resistant plastic or metal carrying case of sufficient size and strength to contain the circular saw, maintenance tools and accessories. Codes and Standards: NEMA - Motors shall conform to National Electrical Manufacturers Association (NEMA) Publication No. MG-1. UL. - All electrical components including motors, switches, and wiring shall conform to the applicable requirements of UL 45. The saw shall bear an identification plate in accordance with the applicable requirements of UL 45. Unless otherwise specified, the saw shall be furnished with an instruction manual in accordance with the applicable requirements of UL 45. ITEM MARKING Mark each item in a permanent and legible manner with manufacturer's part number and name or identifying symbol. PACKAGING One (1) item shall be preserved and packaged in a unit package designed to protect the item against damage during shipment, handling, and storage. PACKING The unit packages shall be packed in a close fitting fiberboard box in compliance with the Uniform Freight Classification and the National Motor Freight Classification requirements of Rules, Item 222, Sec. 3., Minimum 200, or ECT 32. MARKING All unit, intermediate, transport packages and unit loads shall be marked and bar coded for delivery to civilian activities in accordance with the latest version of FED-STD-123, "Marking For Shipment (Civil Agencies)", or marked and bar coded for delivery to military activities in accordance with the latest version of MIL-STD-129, "Military Marking For Shipment and Storage". "Latest version" is defined as the version in effect on the date of bid submittal. Federal Standards and Military Standards can be accessed on-line via the Defense Logistics Agency's "Assist" Quicksearch web site: http://assist.daps.dla.mil/quicksearch/ Palletization: The shipping (transport) containers shall be palletized. The pallets shall be 48-inch length x 40-inch width, general purpose, four-way entry, flush stringer, and double-face non-reversible pallets. The palletized load shall not exceed 2500 pounds in weight for shipments to the Eastern Distribution Center (Burlington). The palletized load shall not exceed 2000 pounds in weight for shipments to the Western Distribution Center (French Camp Location). The palletized load shall not overhang the pallet deck board edge by more than 1 inch and shall not exceed 53 inches in overall height (including pallet). Less than half pallet loads or loads shipped by small package carrier in acceptable transport packing need not be palletized. When less than full but more than a half pallet is used, the palletized load shall utilize proper bracing and/or reinforcement to ensure that the load can withstand two additional loads placed on it. Stacking: A load-stacking test shall be performed once, at the beginning of the contract, for each different unitized or palletized load configuration. A fully palletized load shall be tested utilizing a total stack of three palletized loads, with all the proper bracing and/or reinforcement necessary to perform the test. There shall be no evidence of damage to the pallets, shipping containers or products when stack is tested on the rigid surface for a minimum of 24 hours, in compliance with all the National and Local Safety Regulations. The pre-tested palletized load configuration shall be duplicated using the same packaging materials, pattern, number of shipping (transport) containers, and procedures consistent throughout the duration of the contract. Palletized loads shall be stable and safe when handled with mechanical equipment by qualified personnel. Materials: All lumber used inside or outside a shipment shall be bark free. No used wood pallets with repaired components or stringers will be acceptable. All wood pallet stringers shall be manufactured from hardwoods. Pallets manufactured of materials other than wood, shall conform to all the requirements specified herein. Unitization: For the purpose of this requirement, the assembled group of containers or items in a single load that can be handled as a unit throughout the distribution system. Unitization encompasses, but is not limited to, consolidation in a container, placement on a pallet or load base having forklift capability, or securely binding together. Shipments should be considered for unitization where appropriate or specified. Unitization of pallet load: The palletized load shall be unitized and secured to the pallet to insure that the load arrives intact without product damage. The containers or items shall be placed in a suitable pattern to form a stable and balanced load. Vertical, horizontal or filler reinforcement shall be added as necessary to meet the stacking strength requirements. A palletized load shall be secured to the pallet by shrink or stretch wrapping, and/or, by steel or nonmetallic strapping. When steel or nonmetallic strapping is used, edge protectors shall be provided to prevent damage to the cartons when tensioning the strapping. As a minimum, two straps shall run lengthwise, two straps shall run widthwise, and two straps shall run around the girth of the palletized load. A palletized load shall be capable of protecting the products against damage in a multiple handling, transportation, and storage environment having distribution warehouses with rack systems that support the load/s overhead of warehouse personnel. Notice of special requirements for shipment to European Union countries: Per Clause D-FSS-468, non-manufactured wood pallets and other non-manufactured wood package material used in shipments destined for ultimate delivery to or through a European Union (EU) country shall comply with the Emergency Measures (2001/219/EC) adopted by the Commission of the European Communities (CEC). Additionally, shipments delivered to DoD distribution facilities or freight consolidation points for eventual delivery to or through EU countries shall comply with applicable DLA Regulations and Procurement Letter PROCLTR 02-17.

Similar Contracts

Same NAICS industry code

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS