This Sources Sought opportunity from Department Of Veterans Affairs was posted on July 1, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
5650--American Lake B81 Lab Roof
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
The Department of Veterans Affairs, through Network Contract Office 20, is seeking information from qualified construction firms capable of providing a complete TPO roofing system replacement for Building 81 at the American Lake Campus in Tacoma, Washington. The existing torch-down roof above laboratory storage rooms has suffered persistent leaks despite prior repairs, and the goal is to install a durable, fully integrated roofing assembly that includes membranes, insulation, flashing, sealants, and other components to ensure continuous protection from weather and environmental elements. The project requires minimal disruption to laboratory operations, with air conditioning downtime limited to a single weekend to accommodate the seven critical AC units serving the facility. The estimated contract value ranges between $5 million and $10 million, with a proposed performance period of approximately 120 calendar days following notice to proceed. The NAICS code is 238160, and the small business size standard is $19 million. This notice is strictly for sources sought purposes and does not constitute a solicitation for quotes or proposals; no pricing or formal offers are requested at this time. The Government is gathering information to assess market capability, potential small business participation, and appropriate procurement strategy. Interested parties must respond by email with a completed questionnaire no later than 10:00 AM PDT on July 10, 2026, including contact details, SAM.gov UEI number, business size classification, eligibility for small business programs, a capabilities statement, bonding information, estimated project duration, and up to three relevant past performance examples within the last five years. Subcontractors must disclose their prime contractor and contribution percentage. Compliance with FAR or VAAR limitations on subcontracting is required based on business type. All responses are voluntary, will not be returned, and do not guarantee inclusion in any future solicitation. The Government retains full discretion on whether to proceed with a procurement and will not reimburse any costs incurred in providing responses.
General Info
Agency
NAICS
Place of Performance
Puget Sound HCS American Lake VAMC, Joint Base Lewis-McChord, WA, 98493Set-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
The Department of Veterans Affairs, NCO 20, in support of VA Puget Sound - American Lake Campus, Tacoma, WA is currently requesting information to determine the existence of viable sources capable of providing construction services.
Period of Performance: The intended contract period of performance is approximately 120 calendar days after receipt of notice to proceed.
Description of Services: The Contractor shall furnish all labor, materials, equipment, and supervision necessary to provide and install a complete TPO roofing system. The roofing system shall be a fully integrated, weather resistant assembly that includes all required roofing membranes, underlayment, insulation, flashing, sealants, and finish roofing materials. The system shall be installed in accordance with applicable manufacturer specifications, industry standards, and governing codes. When completed, the roofing system shall provide continuous, complete, and effective protection of the enclosed space below from all external environmental elements, including precipitation, wind, temperature intrusion, and moisture. The air conditioning down-time shall be limited to a weekend to have negligible effect on laboratory operations.
The small flat roof above the laboratory storage rooms in Building 81 has experienced persistent leaks for several years. Although multiple repairs have been attempted, including large applications of tar, the roof continues to fail. The existing torch down roof will be replaced with a TPO roofing system to provide a long term solution. The area includes seven AC units that cool the laboratory below and must remain functional nearly year round.
NAICS Code: 238160 Roofing Contractors Small business size standard: $19 Million
The Government is not soliciting offers at this time, and it will be the Contracting Officer who will determine which suggested changes are accepted. This is a sources sought notice to gain knowledge of potential qualified sources. A solicitation is not currently available.
Responses: Responses to this request will be considered for the purpose of determining how the requirements will be stated and how the procurement will be conducted. This announcement is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or to award a contract. No reimbursement will be made for any costs associated with providing information in response to this synopsis or any follow-up information requests.
If you are interested and can provide the required services, please complete the questionnaire below and email your response to Ty.Draszt@va.gov. no later than 1000 AM PDT, July 10, 2026. Include any comments or questions you may have. Also provide your capability statements within your response.
A SOURCES SOUGHT QUESTIONNAIRE is below. Responses to the Questionnaire are encouraged from all interested parties. You are advised that providing responses to the questions will not automatically include you in the acquisition process for this solicitation. Please provide any additional feedback in your response that you feel is relevant.
Responses are requested with the following information and shall not exceed a total of 5 (five) pages. Email subject line needs to contain the sources sought number 36C26026Q0790 Please provide the following information: Contact information: Name, address, SAM.gov UEI number, and points of contact with telephone numbers and e-mail addresses. Business Size/Classification (based on NAICS 238160): Is your firm eligible for participation in one of the following small business programs? If so, please indicate the program.
[ ] yes [ ] no Small Business (SB) [ ] yes [ ] no HUBZone [ ] yes [ ] no Small Business 8(a) [ ] yes [ ] no Small Disadvantaged Business (SDB) [ ] yes [ ] no Women-Owned (WO) Small Business [ ] yes [ ] no Service-Disabled Veteran Owned Small Business (SDVOSB) [ ] yes [ ] no Veteran Owned Small Business (VOSB) [ ] yes [ ] no Other (please specify)
Capabilities Statement: Description of capabilities to perform construction services as described above and project experience demonstrating relevant experience similar to those described. Include bonding capability information that is consistent with estimated magnitude between $5,000,000 and $10,000,000. Govt. does not have a waiver to Buy American. SDVOSB or VOSB businesses please include statement on maintaining compliance with VAAR 852.219-75 VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction, 852.219-76 VA Notice of Limitations on Subcontracting Certificate of Compliance for Supplies and Products. All other socio-economic businesses please include statement on maintaining compliance with FAR 52.219-14 Limitations on Subcontracting. Time: Based on the information provided, please estimate the total project time in days. Past Performance/experience: Provide information on contracts of similar scopes of work or construction contracts, briefly describe no more than three (3) contracts (or specific task orders) completed within the past five years of the issue date of this Sources Sought notice. The past performance information should include: Project Title/Contract Number Location: City, State General description of the construction to demonstrate relevance to the proposed project Offerors role Dollar value of contract Name of the company, agency, or government entity for which the work was performed What types of information is required to submit accurate offers? If submitting past performance/experience on a project in the role of a subcontractor, include the Prime Contractor s name and a quantifiable amount (percentage) of the project your company contributed to the overall scope of work. Note: Do not include Proprietary, classified, confidential, or sensitive information in responses.
NO RESPONSES WILL BE ACCEPTED BY FAX. Responses will not be returned. Telephonic responses will not be honored. Please respond by email only. Send responses to the Contracting Officer Ty Draszt via email at Ty.Draszt@va.gov.
More opportunities from Department Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS