59--Velcon Systems TDS5-1 Main Unit Transformer Oil Purifier & mositure Dryer for the Bonneville Lock and Dam in Cascade Locks, OR

Awarded
W9127N11Q0035Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334416
New
DIBBS
SHIELDING GASKET, ELECT
Solicitation # SPE7M5-27-T-1161
Solicitation SPE7M5-27-T-1161 is a fixed-price request for quotations issued by the DLA Weapons Support Active Devices Division for 43 electronic shielding gaskets, identified as NSN 5999-01-167-4704. This is designated as a critical application item that must be produced in accordance with Technical Data Package Rev A Gen 3, specifically Basic Drawing 18876 13092455 and Reference Drawing 18876 MIS-35351. The required delivery date is February 25, 2027, with the place of delivery being the DLA Distribution DDSP New Cumberland Facility in Pennsylvania. The procurement includes stringent quality and security requirements. Manufacturers must maintain an inspection system compliant with SAE AS9003 or ISO 9001 tailored to SAE AS9003, and inspection and acceptance will occur at the origin. Due to the nature of the technical data, offerors must have an approved US/Canada Joint Certification Program certification and DLA approval to access export-controlled data subject to ITAR or EAR. Additionally, the contract mandates compliance with CMMC Level 2 and DFARS 252.204-7012 for safeguarding covered defense information. Packaging must adhere to MIL-STD-129 and RP001, with specific labeling required for hazardous materials per the Hazard Communication Standard. Notably, the government will not evaluate or award to offers utilizing additive manufacturing processes. Eligible HUBZone small businesses may receive a price evaluation preference. All payment requests and receiving reports must be processed electronically through the Wide Area WorkFlow system.
DLA WEAPONS SUPPORT ACTIVE DEVICES DIVISION

POSTED

1 day ago

DEADLINE

in 3 days

AI Contract Overview

Show more

This solicitation, number W9127N11Q0035, is issued by the Department of Defense via the W071 Endist Portland for the procurement of a Velcon Systems TDS5-1 Main Unit Transformer Oil Purifier and moisture Dryer. The equipment is intended for use at the Bonneville Lock and Dam located in Cascade Locks, Oregon. Due to a brand name justification, only Velcon brand equipment will be considered for this purchase. This opportunity is designated as a total small business set-aside under NAICS code 334416. Prospective offerors must be registered in the CCR database and provide all required submittals specified on page three of the solicitation to be eligible for award. All inquiries must be submitted via email, as phone responses will not be provided, and answers will be distributed through amendments on ASFI and Fed Biz Ops. The government intends to award the contract to the technically acceptable offeror providing the lowest price. The response deadline for this combined synopsis and solicitation was March 11, 2011.

General Info

Contract Value

$71,256.48

NAICS

334416 - Capacitor, Resistor, Coil, Transformer, and Other Inductor Manufacturing

Place of Performance

USACE District, Portland Contracting Division (CECT-NWP), P.O. Box 2946 Portland OR 97208-2946 US, OR, USA

Set-Aside

SBA

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Combined Synopsis

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W071 Endist Portland
ContactsNo contacts available
OfficePORTLAND, OR, 97204-3495, USA
Office AddressPORTLAND, OR, 97204-3495, USA
ContactsNo contact information available

Full Description

Show more
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This solicitation is for Velcon Systems TDS5-1 Main Unit Transformer Oil Purifier & mositure Dryer for the Bonneville Lock and Dam in Cascade Locks, OR, as per the attached Brand Name Justification. Only the Velcon Brand equipment shall be considered for this purchase. All potential offerors MUST be registered in the CCR database and MUST submit all the required submittals on Page THREE (3) of the solicitation to be considered for award. Any questions MUST be submitted by e-mail. All answers will be posted by an amendment to the solicitation on ASFI and Fed Biz Ops. No questions shall be answered by phone. It is the intent of the Government to award this purchase to the offeror that is technically acceptable and has the lowest price.

More opportunities from Department Of Defense → W071 Endist Portland

Same awarding agency

NAICS: 238220
New
Federal
John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)
Solicitation # W9127N27BA007
Solicitation W9127N27BA007 is a firm-fixed-price contract issued by the U.S. Army Corps of Engineers, Portland District, for comprehensive HVAC upgrades at the John Day Dam Powerhouse in Rufus, Oregon. The project scope involves replacing failing automation and non-compliant systems with a modern automated HVAC control system, including the installation of four skid units totaling approximately 600 tons of refrigeration, new distributing ducting, roof-mounted air-cooled condensers, and substantial fire protection upgrades. The work is divided into several line items, including mobilization, rehabilitation of dry and wet side HVAC systems, monitoring and control systems, seasonal testing and balancing, and asbestos survey and abatement. The overall period of performance is 1,004 calendar days from the date of the Notice to Proceed, with approximately 5 million dollars currently available for payment. Interested offerors must be registered in PIEE and provide their CAGE Code and CMMC Unique Identifier to access restricted Controlled Unclassified Information (CUI) drawing packages. Bids are due by December 28, 2026, and will be evaluated with a 10 percent price preference for HUBZone small business concerns. The contract mandates strict adherence to cybersecurity standards per DoD Instructions 8500.01 and 8510.01, as well as compliance with the Buy American Requirement-Construction and prevailing wage laws. Final acceptance is contingent upon a formal inspection involving the Contracting Officer and the contractor's quality control personnel, with electrical systems requiring independent testing according to NETA ATS 2025 standards.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

2 days ago

DEADLINE

in about 2 months
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS