Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Department Of Homeland Security was posted on August 18, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6 x 8 Security Booth

Closed
13603PR230010384Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 236210
New
Federal
Building 215 Clean Room HEPA Filter Replacement
Solicitation # RFI-195000-26-00181
The National Institute of Standards and Technology is conducting market research through a Request for Information for the Building 215 Advanced Measurement Laboratory cleanroom repair and HEPA filter replacement project in Gaithersburg, Maryland. This initiative follows a previous solicitation that failed to produce an acceptable offer, prompting NIST to reassess its acquisition strategy and seek industry feedback on constructability, cost, and schedule feasibility. The project scope involves the modernization of an 1,800 square meter facility, including the replacement of approximately 1,200 HEPA filters, 70 VAV terminal units, and 54 airflow monitoring devices, as well as the installation of 32 exhaust air control valves and associated ductwork repairs, testing, and recertification. A critical component of the project is the proposed phasing plan, which aims to minimize research disruptions by utilizing 19 construction phases, including 18 critical cleanroom outage phases. Each critical outage is currently envisioned as a nine-day window starting Friday evening and requiring 24/7 operations to achieve ready-for-re-occupancy by the following Monday morning. NIST is specifically requesting rough-order-of-magnitude cost estimates and industry input on whether this aggressive outage schedule is realistic or if it creates prohibitive risks and costs. Responses, including company experience and recommendations for improving competition and project execution, are due by October 14, 2026.
Department Of Commerce Nist

POSTED

1 day ago

DEADLINE

in 13 days
NAICS: 236210
New
Federal
Sources Sought - POST TEST LITHIUM BATTERY STORAGE
Solicitation # N00167-27-RFPREQ-CD-102-0002
The Naval Sea Systems Command Naval Surface Warfare Center Carderock Division is conducting a sources sought effort for the construction of a Post-Test Lithium Battery Storage Facility in West Bethesda, Maryland. This project, classified under NAICS code 236210 for Industrial Building Construction, involves the creation of a storage area featuring a non-flammable single-pitch sloped roof, a perimeter fence with a gate, 3-hour rated firewalls, and concrete walls for large battery storage. Additional requirements include low-voltage outlets, pole-mounted LED flood lighting, and a dedicated forklift access road. The effort must be completed within 210 days of the award and adhere to Unified Facilities Guide Specifications and other stringent technical criteria. This notice is not a request for proposal, and no award will be made directly from this notice. Interested small and large businesses must submit a capability statement and a Rough Order of Magnitude by 1700 EST on 18 November 2026 to Heather Valiga. The government will use these responses to determine the future acquisition strategy. Because the project is located on a secure military installation, all personnel must obtain proper clearances and credentials. Key deliverables include an Activity Hazard Analysis and a detailed schedule due within five days of the pre-construction meeting, as well as a personnel list provided seven days before the start date.
Nswc Carderock

POSTED

1 day ago

DEADLINE

in 29 days
NAICS: 236210
New
SLED
Arrowhead Regional Medical Center Lot 1 Parking Structure
Solicitation # 2026010330
The County of San Bernardino is soliciting the construction of the Arrowhead Regional Medical Center Lot 1 Parking Structure located at 400 North Pepper Avenue in Colton, California. The project consists of a post-tensioned, cast-in-place structure spanning up to 500,000 square feet across six levels, providing up to 1,600 parking spaces. Key design elements include a finished exterior with an architectural mesh facade on the first floor, two banks of two elevators, and the installation of photovoltaic panels on the top level. The facility will be restricted to employees via badge access and will feature security enhancements such as LED lighting, emergency call boxes, security cameras, and locked gates. The project must comply with the California Building Code, the Americans with Disabilities Act, the 2022 California Building Energy Efficiency Standards (Title 24), and the California Green Building Standards Code (CALGreen) for electric vehicle charging stations. Environmental mitigation includes a landscape plan to offset the removal of approximately 51 trees. To maintain parking capacity during construction, a temporary surface parking lot will be operated at 1351 West Valley Boulevard with shuttle services provided to the campus. The project has undergone CEQA review, resulting in a Mitigated Negative Declaration confirming that the project will not have significant environmental impacts provided mitigation measures are implemented.
San Bernardino County

POSTED

1 day ago

DEADLINE

N/A

General Info

NAICS

236210 - Industrial Building Construction

Place of Performance

San Pedro, CA, 90731, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

3 updates
PhaseClosed
Posted

Solicitation

Notice updated

The notice description changed.

Notice updated

Response deadline changed from Aug 18, 2023 to Aug 21, 2023. The notice title changed. The notice description changed.

Notice updated

The notice title changed. The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Homeland Security → Base Los Angeles/long BEACH(00037)
Contacts2 people available
OfficeSAN PEDRO, CA, 90731, USA
Office AddressSAN PEDRO, CA, 90731, USA

Full Description

Show more
Greetings! We require a 6 x 8 security booth with lifting slots for a forklift that will serve as our quarterdeck booth for our cutter. We will review all quotes that are submitted and make our choice based on lowest bid price. Once we determine the lowest bid, we will reach out to the awarded vendor via email and to all vendors that submitted quotes with the final decision. This solicitation is time sensitive, so please submit an accurate quote with your final offer. Contract specialist will not attempt to negotiate for a better price or lead time and will evaluate all quotes at face value. Vendor must be registered and active in SAM.gov. We request that interested vendors provide 2 separte quotes; 1 for Net 30, purchase order, payment terms and 1 for credit card payment terms. This product is to be delivered to 1001 S. Seaside Ave. San Pedro, Ca 90731. Please let me know if you have any clarifying questions and I will answer them in an expeditious manner. See below for specifications: Unit to be designed for exterior use and constructed of minimum 2 x 2" x .083 structural steel tube frames with R-10 insulated, 16ga galvanized steel interior and exterior walls, with an additional layer of continuous exterior R-9.6 insulation encapsulated in the final exterior layer of 16ga. galvanized steel panels. Overall rating for the wall insulation is R-19.6. Roof to be insulated to R-19 and constructed of internal steel framing with 16ga. galvanized steel decking welded to the framing and then coated with a three part membrane with a solar reflective index of 95 or greater. Roof will have a 10 fascia and 6 overhang on all sides. Roof to drain to rear downspouts. 12ga. Galvanized steel plate floor covered with black polyvinyl chloride commercial black resilient textured 20 x 20 inter locking tiles and 4" high black base cove, floor system is welded to a 3" galvanized steel tube frame and joists. One commercial steel framed sliding door top hung by a minimum of eight 2 1\4 rigid steel ball bearing rollers with a lower stainless steel guide, stainless steel handles welded to the frame and mortise lock. Fixed windows on all sides glazed with 3/4" clear tempered dual pane insulating glass with Low-E coating. Interior 1 x 4 LED light recessed in a galvanized steel ceiling painted the match the booth and mounted at 90 AFF. Light is controlled by dimmer switch. One interior 6 diameter LED down light with red shielding for task lighting, light is controlled by a wall mounted dimmer switch. Prewired 120/240 volt 12 pole 125 amp rated single phase load center wired to a exterior weather tight shore power plug. Three duplex outlets mounted under a 20 deep full width type 304 stainless steel work counter. One exterior weather tight 6 x 6 J-Box with a 1 1\2 conduit through the wall to a 6 x 6 interior J-Box. Commercial through the rear wall mounted HVAC with 12,000 BTU cooling and 11,200 BTU electric heating and a 230 volt dedicated outlet. 1500 watt fan forced wall mounted auxiliary heater with integral thermostat. Booth will be painted one color of customers choice using high solids polyurethane paint over two part polyurethane primer Provide welded in place C-Channel forklift pockets in the floor frame

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS