Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, July 22 at 2:00 PM EDT

Register Free →

61 -- Provide 11kV switchgear and additional accessories

Active
W91GXY-06-Q-0132Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This contract involves a firm-fixed-price agreement for the supply of 11kV switchgear along with additional accessories. The required delivery location is the PWC warehouse in Abu Ghraib, Iraq, with a delivery timeline of 60 days after receipt of order. Shipping instructions will be detailed in the formal award documents. The contract's estimated value ranges from $1,000,000 to $5,000,000. The solicitation for this contract is accessible online and has been re-numbered to W91GXY-06-R-0075, which should be referenced in all related correspondence. The contract is managed by the Department of Defense through the W6QK Ele Rcc Kabul office, with a principal contact named William E Harper. It falls under NAICS code 237130 and relates to construction or utility infrastructure services. The solicitation initially appeared as a presolicitation and is designed to acquire equipment critical for electrical distribution and infrastructure improvements in the designated area of operations.

General Info

Firm-fixed-price contract for 11kV switchgear delivery to Abu Ghraib, Iraq, valued $1M-$5M.

Agency

Department Of Defense → W6QK Ele Rcc KabulView Agency

NAICS

237130 - Power and Communication Line and Related Structures ConstructionView NAICS

Place of Performance

To be delivered 60 days ARO to PWC warehouse, Abu Ghraib, Iraq., AE

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

1 update
PhasePresolicitation
Posted

Presolicitation

Amendment 1

Contract was updated

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W6QK Ele Rcc Kabul
Contacts1 person available
OfficeAPO, AE, 09354, USA
Organization / Agency
Department Of Defense → W6QK Ele Rcc Kabul
View Agency Profile
Office AddressAPO, AE, 09354, USA
Contacts
William E HarperPrincipal Acquisition Analyst

Full Description

Show more
This solicitation is for a Firm-Fixed-Price (FFP) contract for 11kV switchgear and additional accessories to be delivered 60 days ARO to PWC warehouse, Abu Ghraib, Iraq. Detailed shipping instructions will be included with the actual award document. The estimated price is between $1,000,000 and $5,000,000. The solictation should be available from www.rebuilding-iraq.net on or about 16 Jun 2006. This solictation is now RE-NUMBERED to W91GXY-06-R-0075. Please use the new solicitation number on all correspondence.

Similar Contracts

NAICS: 237130
New
SLED
Public Safety DAS UpgradeThe contract involves the demo and installation of a Distributed Antenna System (DAS) designed to enhance public safety communications, including Bi-Directional Amplifiers, antennas, cabling, fiber optic infrastructure, patch panels, and all other equipment specified in the approved design. This system is critical and built with redundancy to ensure uninterrupted operation, particularly in emergency scenarios. The work must comply with strict technical standards, and the contractor is responsible for conducting comprehensive coverage testing and system commissioning to validate that performance meets all design and operational requirements. The project is managed by the Port of Seattle’s Aviation Project Management Group, with Leila Gonzalez-Rigatto serving as the primary point of contact and Rishiraj Savita as the project manager. The solicitation is listed as a forecast with a NAICS code of 237130, indicating it relates to telecommunications infrastructure construction. Although no solicitation number or set-aside details are provided, the timing of the posting suggests the opportunity is being previewed for interested vendors ahead of a formal procurement. The place of performance and specific location details are not listed, but the context implies the work will be conducted at a Port of Seattle aviation facility requiring upgraded public safety radio coverage.
Aviation Project Management Group

POSTED

about 5 hours ago

DEADLINE

N/A
View Details
NAICS: 237130
New
SLED
27-007 Corrective Pole MaintenanceThe City of Albany is soliciting sealed bids for corrective maintenance on its 12KV electrical distribution system, specifically to replace faulty or deteriorated wood power poles with new ones along with associated powerline equipment and hardware. Bids must be submitted to the Procurement Division at 222 Pine Avenue, Suite 260, Albany, Georgia, no later than 2:30 p.m. on August 14, 2026, and only contractors employing certified and qualified linemen will be considered. The work scope is defined by a general map and specific facility locations provided in the formal bid package, ensuring precise identification of project sites. This procurement is identified under solicitation number PE-64750-NONST-2027-000000207 and titled 27-007 Corrective Pole Maintenance, with the posting date listed as July 13, 2026. The contract falls under a state and local government procurement and is not subject to any set-aside classification. Joshua Williams serves as the primary point of contact for the solicitation and can be reached at 229-431-3211 or jswilliams@albanyga.gov for inquiries regarding the bid requirements. While the official address details for the agency and place of performance are not fully specified in the data, all work is confined to the City of Albany within the state of Georgia. Bidders should refer to the provided online portal listed in the contract data for full documentation and to ensure compliance with all submission guidelines. The successful contractor will be expected to perform maintenance activities in accordance with industry standards and municipal safety protocols, ensuring uninterrupted service and reliability of the city’s electrical infrastructure.
City of Albany

POSTED

1 day ago

DEADLINE

in about 1 month
View Details
NAICS: 237130
New
Federal
USACE SPK DB Construction – DDJC Centralized Gas and Electric Metering - Tracy, CAThe United States Army Corps of Engineers Sacramento District anticipates a solicitation for the design, furnishing, and installation of new commercial electric and natural gas meters with integrated monitoring hardware at Defense Distribution Depot San Joaquin in Tracy, California. The project involves standard electrical construction, conduit work, and the deployment of Commercial-Off-The-Shelf metering equipment capable of outputting standardized usage data to a local station for facility monitoring and operational verification. The work is estimated to cost between five and ten million dollars and is expected to be completed within 900 calendar days after notice to proceed. The government plans to issue a firm-fixed price contract using NAICS code 237130 and PSC code Y1NZ, with the solicitation targeted for mid-July 2026 and award anticipated by September 2026. The procurement is set aside exclusively for Women-Owned Small Businesses, with all proposals required to be submitted through the Procurement Integrated Enterprise Environment. All potential offerors must be registered in both the System for Award Management and PIEE prior to the proposal deadline, as submissions via any other method will not be accepted. A pre-proposal site visit is planned for approximately July 15, 2026, with exact details to be provided in the official solicitation. Interested parties must regularly monitor PIEE and SAM.gov for the release of the solicitation, any amendments, or updates, as the government will not proactively notify vendors. Solicitation documents will be available in PDF format and require Adobe Acrobat Reader for access. Registration in PIEE is mandatory to submit proposals, though documents may be downloaded without registration. Contractors are responsible for identifying themselves as interested vendors on SAM.gov and must not rely on the government for coordination, capability reviews, or partnership facilitation. The solicitation number is W9123826RA018, and primary points of contact are Antonina Beal and Julie Maxwell. The project is subject to change, delay, or cancellation at any time without notice.
W075 Endist Sacramento

POSTED

1 day ago

DEADLINE

N/A
View Details
NAICS: 237130
New
Federal
Tower Maintenance IDIQ Radar Operations CenterThe U.S. Department of Commerce, NOAA, is seeking to establish a five-year Indefinite Delivery, Indefinite Quantity (IDIQ) contract for the maintenance, inspection, repair, and engineering support of the NEXRAD WSR-88D radar tower network, with the solicitation number 1305M226Q0101 and a total small business set-aside under FAR 19.5 and NAICS code 237130. The contract will be awarded to a qualified small business capable of performing three distinct line items: CLIN 0001 for tower inspections and engineering evaluations, CLIN 0002 for structural repairs, replacement, and galvanic coating restoration, and CLIN 0003 for engineering data submissions and change proposals. Performance is centered at the Norman, Oklahoma radar operations center, with work occurring at all 160 WSR-88D tower sites nationwide. Proposals must include Volume I (Price Quote), Volume II (Technical Proposal), and Volume III (Past Performance) in accordance with Section L requirements, and failure to submit all required documentation will result in a nonresponsive offer. The deadline for submission has been extended to July 29, 2026, and bidders must acknowledge all posted amendments, including revisions to the Instructions to Offeror and Evaluation attachments. All work must comply with stringent safety and quality standards, including OSHA CFR 1910-268, ANSI Z359, ANSI Z490, and NATE CTS, with all tower climbers required to hold valid certifications and use OSHA-compliant personal protective equipment. The contractor must submit a comprehensive safety plan with the initial proposal and with each task order, including certifications for personnel and equipment. Work must be preceded by a minimum of seven calendar days’ notice to the Contracting Officer Representative, except in emergencies, and will be coordinated through designated Government points of contact who will assist with site access and radar system shutdowns. Deliverables include detailed inspection and engineering reports, submitted digitally via email within 30 days of completion, which must contain contract and task order numbers, CLIN, date of completion, and the on-site Government POC. Quality acceptance requires 100% COR inspection and adherence to strict tolerances: reports must contain fewer than two errors, corrections must be addressed within three business days, and repairs must achieve a 95% defect-free rate.
Department Of Commerce Noaa

POSTED

1 day ago

DEADLINE

in 15 days
View Details