Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity was posted on February 26, 2016. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

63--RADIATION DETECTION

Awarded
VA25016Q0144Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334511
New
Federal
Automated Traffic Enforcement Trailer
Solicitation # W911S226U4411
Solicitation W911S226U4411 is a Total Small Business Set-Aside for the procurement of a complete, towable, autonomous mobile traffic enforcement trailer and laser-based measuring system for the Department of Defense at Fort McCoy, Wisconsin. The primary requirement is for one Automated Traffic Monitoring System Trailer, specifically the POLISCAN Speed FM1 or an approved equal, capable of tracking multiple vehicles across at least four adjacent traffic lanes to enforce speed limits and red-light violations. The contract includes a requirement for eight hours of on-site operator training at Fort McCoy and a minimum 12-month comprehensive manufacturer's warranty. All equipment must be new, and the system must be calibrated to federal and state standards to ensure data is legally admissible in court. The award will be granted to the responsible offeror whose proposal is most advantageous to the government based on price and technical evaluations. Delivery is required F.O.B. Destination to Fort McCoy, with a preferred delivery window of 30 days. Offerors must submit their proposals via the PIEE Solicitation module, including technical, price, and past performance documentation. A critical requirement for responsiveness is the completion of Attachment 1 regarding certifications and the identification of the country of origin. The contract incorporates various regulatory clauses, including Buy American preferences, cybersecurity reporting under DFARS 252.204-7012, and prohibitions on certain telecommunications equipment.
W6QM Micc-Ft Drum

POSTED

about 9 hours ago

DEADLINE

in 7 days

General Info

Agency

N/A

Contract Value

$7,045.04

NAICS

334511 - Search, Detection, Navigation, Guidance, Aeronautical, and Nautical System and Instrument Manufacturing

Place of Performance

DEPARTMENT OF VETERANS AFFAIRS;10701 EAST BLVD.;CLEVELAND, OHIO 44106 USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Combined Synopsis

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
ContactsNo contacts available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The solicitation number is VA250-16-Q-0144 and is issued as a request for quotation (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-86-2. The requirement is for Brand Name or Equal Radiation Detection. Delivery location is Cleveland VAMC in Cleveland, Ohio and shall be FOB destination. Delivery and installation required within 30 days of contract award. This announcement constitutes the only solicitation; a formal, written solicitation will not be issued. PAPER COPIES OF THIS SOLICITATION WILL NOT BE AVAILABLE. This solicitation documents and incorporates provisions and clauses in effect through FAC 2005-86-2. It is the responsibility of the contractor to be familiar with the applicable clauses and provisions. The clauses may be accessed in full text at these addresses: https://www.acquisition.gov. The selected Offeror must comply with the following commercial item terms and conditions, which are incorporated herein by reference: FAR 52.212-1, Instructions to Offerors -Commercial Items, FAR 52.212-3, Offeror Representations and Certifications-Commercial Items - the selected offeror must submit a completed copy of the listed representations and certifications or confirm that the annual representations and certifications was completed electronically via the SAM website accessed through https://www.sam.gov. FAR 52.212-4, Contract Terms and Conditions-Commercial Items; FAR 52.212-5, Contract Terms and Conditions Required To Implement Statutes or Executive Orders-Commercial Items, paragraph (a) and the following clauses in paragraph (b): 52.219-6, 52.219-28, 52.222-3, 52.222-19, 52.222-21, 52.222-26, 52.222-36, 52.223-18, 52.225-1, 52.225-13, 52.232-34. The full text of the referenced FAR clauses may be accessed electronically at https://www.acquisition.gov. The following VAAR Clauses apply 852.203-70 Commercial Advertising 852.-211-73 Brand Name or Equal 852.232-72 Electronic submission of payment requests 852.246-70 Guarantee 852.246-71 Inspection Offer Evaluation and Award: This is a competitive Request for Quotations (RFQ) that will be evaluated under FAR Part 13. The Government will issue a Firm-Fixed Price Purchase Order resulting from this solicitation to the responsible offeror whose offer conforms to the requirements within this solicitation and will be the most advantageous to the Government, price and other factors considered. The following factors will be used to evaluate offers: Price Technical (capability of offer to meet the Government's needs) Delivery/Installation Availability Past Performance All evaluation factors other than cost or price, when combined, are significantly more important than cost or price. An Offeror's initial quote should contain the best terms from a price and technical standpoint. Offerors are reminded that representatives from your company SHALL NOT contact any Cleveland VAMC personnel to discuss this RFQ during the solicitation and evaluation process. All questions and concerns regarding this solicitation shall be directed to Rachelle Hamer via email at contact@example.gov and should be received no later than 5:00pm EST on March 4, 2016. ? STATEMENT OF WORK (SOW) 1. Scope. The Radiation Detection for Waste Release Monitor is ideal for monitoring personnel or laundry for possible contamination that may have been unknowingly spilled. The monitor may also be used as a radiation contamination triage device to alert emergency department personnel of potentially contaminated patients or equipment coming into the emergency room. Both detectors are continuously monitored by the digital controller so any offending item can immediately trigger an alarm. Alarm conditions can be set up to automatically halt production conveyance devices, notify the central office, and even alert key personnel to initiate an immediate response. 2. Specific Tasks. This device will facilitate a more rapid and uniform inspection by placing two relatively large sized scintillation detectors in close proximity to the incoming or outgoing articles undergoing inspection. Both detectors are continuously monitored by the digital controller so any offending item can immediately trigger an alarm. Alarm conditions can be set up to automatically halt production conveyance devices, notify the central office, and even alert key personnel to initiate an immediate response 3. Specifications. DETECTOR: 2 ea. 2753 cm³ (168 in³) plastic scintillation detectors. Each detector is supplied with a 15.2 m (50 ft) coaxial cable. DISPLAY: 4-digit LED display with 2 cm (0.8 in.) digits DISPLAY UNITS: can be made to display in microR/hr, mR/hr, R/hr, microSv/h, mSv/h, Sv/h, cpm, cps, and others RANGE: 0.0 to 9999 kcps LINEARITY: reading within 10% of true value RESPONSE: typically 3 seconds from 10% to 90% of final reading STATUS: (green light) instrument functioning properly SIGMA ALARM: indicated by red ALARM light and audible tone (can be set at any point from 0.0 to 999 sigma) SUM ALARM: indicated by red ALARM light and audible tone (can be set at any point from 0.0 to 9999 kcps). NOTE: audible alarm annunciators can be configured as a single beep if desired DET FAIL: (red light and audible tone; greater than 68 dB at 61 cm [2 ft]) indicates no counts from detector or instrument failure LOW BAT: (yellow) indicates less than 2 hours of battery power remaining OVERRANGE: indicates measured radiation field has exceeded counting range of instrument (indicated by display reading "--") RELAY OUTPUT: mains (120 or 240 Vac) output on alarm, 9-pin connector providing RS-232 output, signal ground connection, FAIL and ALARM signals (current sink), and direct connection to battery and ground CALIBRATION CONTROLS: accessible from front of instrument (protective cover provided) POWER: 95-135 Vac (178-240 Vac available), 50-60 Hz, 6 volt sealed lead-acid rechargeable battery (built-in) BATTERY LIFE: typically 24 hours in non-alarm condition BATTERY CHARGER: battery is continuously trickle-charged when instrument is connected to line power and turned on CONSTRUCTION: aluminum housing with ivory powder-coat paint TEMPERATURE RANGE: -15 to 50 °C (5 to 122 °F) SIZE: electronics: 26.2 x 24.6 x 8.4 cm (10.3 x 9.7 x 3.3 in.) (H x W x L) detectors (ea.): 104.1 x 17.1 x 5.4 cm (41 x 6.75 x 2.125 in.) (H x W x L) WEIGHT: electronics: 4.2 kg (9.3 lb); detectors (ea.): 10.7 kg (23.5 lb) OPTIONS: Date/Time Printer with Cable (Part Number 4396-072) shown External Enunciator Option for the Model 375 (Part Number 4396-171) Model 271-2 Remote Display Area Monitor with dual alarm channels, audio On/Off, reset button (PN 48-3536) Horn/Red Alarm Strobe: Model ALM-220, with 14.2 m (50 ft) cable and 220 V relay (Part Number 4396-173) shown Environmental Enclosure for Model 375 electronics: NEMA 4 Weatherproof Enclosure (Part Number 4396-068)

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS