Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

65--Defibrillators Upgrade Intent to Orally Solicit - Set-aside for SDVOSBs

Active
36C26018Q9698Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The contract involves upgrading two Zoll R Series Defibrillators to include Pulse Oximetry (SpO2), End Tidal Carbon Dioxide (EtCO2), and Non-Invasive Blood Pressure (NIBP) monitoring capabilities, ensuring they align with the specifications of the existing fleet. The SpO2 module must be compatible with the Zoll R Series and use Zoll/Masimo LNCS sensors to provide continuous, noninvasive monitoring of arterial oxygen saturation and pulse rate, with configurable alarm settings and detailed display metrics including plethysmogram and signal strength. The EtCO2 module is required to monitor end tidal carbon dioxide and respiratory rate continuously, compatible with specific CO2 sensors and respiratory accessories from Zoll/Respironics, providing real-time values, capnograms, and user-selectable alarm limits. The NIBP module must utilize Zoll-supplied cuffs and connectors to noninvasively measure arterial blood pressure in critical care and transport settings. It should allow multiple measurement modes, including single, STAT, and repeated automated readings with adjustable alarm limits, displaying systolic, diastolic, and mean pressures along with pulse rate. Additionally, the upgrade includes a multi-bay charging station compatible with the defibrillator’s lithium-ion batteries, featuring a 200-watt capacity, RS-232 communication port, and graphic interface. The rechargeable battery packs should offer high-capacity lithium-ion chemistry, run-time indicators, automatic calibration readiness, and usage history storage. This upgrade aims to enhance monitoring capabilities and operational efficiency for critical care and transport scenarios.

General Info

Upgrade two Zoll R Series defibrillators with SpO2, EtCO2, NIBP modules, and multi-bay charger.

Agency

N/A

NAICS

334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing

Place of Performance

Not specified

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

special-notice

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyN/A
ContactsNo contacts available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Salient Characteristics for Zoll R Series Defibrillator Upgrade: The BVAMC must upgrade Qnty. 2 Zoll R Series Defibrillators with SPO2, EtCO2, and NIBP functionality to conform to existing fleet. Pulse Oximetry (SPO2) Module Salient Characteristics: Pulse Oximetry (SPO2) Module must be compatible with Zoll R Series Defibrillator. Pulse Oximetry (SPO2) Module must use Zoll/Masimo LNCS sensors. Pulse Oximetry (SPO2) Module option must continuously and noninvasively measure the oxygen saturation of arteriolar hemoglobin at a peripheral site (e.g., foot, toe, or finger). Pulse Oximetry (SPO2) Module must display the following pulse oximetry information in the SPOW area on the Zoll R Series Defibrillator: SpO2 value (arterial oxygen saturations percentage) SpO2 alarm indicator Signal strength indicator Plethysmogram Pulse Oximetry (SPO2) Module must allow the following adjustments to the SpO2 Settings on the Zoll R Series Defibrillator: Sensitivity level Measurement averaging period Plethysmogram display SpO2 alarm state and limits Technical Specification Minimums: Saturation Range (%SpO2): 1% to 100% Saturation resolutions: 1% Saturation accuracy: No-motion conditions (Adult): 70% to 100%, ±2% Motion conditions (Adult): 70% to 100%, ±3% Saturation alarm limits: On/Off displayed on monitor; operator-selectable Low limit: 70% to 98% High limit: 72% to 100% SpO2 Wavelength: Nominal Red LED Wavelength: 660 nanometers Nominal Infrared LED Wavelength: 905 nanometers Pulse rate range: 25 to 240 beats per minute Pulse rate resolution: 1 beat per minute Pulse rete accuracy: No-motion conditions: 25 to 240 beats per minute, ±3 beats per minute Motion conditions: 25 to 240 beats per minute, ±5 beats per minute Pulse rate alarm limits: On-Off displayed on monitor; operator selectable Low limit: 20 to 100 beats per minute High limit: 60 to 235 beats per minute End Tidal Carbon Dioxide (EtCO2) Module Salient Characteristics: End Tidal Carbon Dioxide (EtCO2) Module must be compatible with Zoll R Series Defibrillator. End Tidal Carbon Dioxide (EtCO2) Module must be compatible with Zoll/Respironics Novametrix CARNOSTAT 5 sensors and LoFlo modules, airway adapters, nasal and nasal/oral cannula sets. End Tidal Carbon Dioxide (EtCO2) Module option be indicated for the continuous noninvasive monitoring of end tidal carbon dioxide (EtCO2) and respiration rate in patient requiring ventilator support, in-hospital transport, or anesthesia. End Tidal Carbon Dioxide (EtCO2) Module must support two methods for continuous measurement of end tidal carbon dioxide (EtCO2) and respiration rate. Use of CAPNOSTAT 5 Mainstream CO2 sensor attached to an airway adapter that connects to an endotracheal tube, mask or disposable mouthpiece. Use of LoFlo CO2 module to monitor both non-intubated and intubated patients using specially designed sampling cannulas and airway adapters. End Tidal Carbon Dioxide (EtCO2) Module must display the following End Tidal Carbon Dioxide (EtCO2) information in the CO2 display area on the Zoll R Series Defibrillator: CO2 value in mmHg Respiratory Rate CO2 alarm indicator Capnogram Technical Specification Minimums: Transducer Type: Mainstream Side stream Principle of Operation: Non-Dispersive Infrared (NDIR) single beam optics, dual wavelength, no moving parts. EtCO2 Measurement Range: 0-150 mmHg 0-20% 0-20 kPa EtCO2 Accuracy: 0-40 mmHg, ±2 mmHg 41-70 mmHg, ±5% of actual 71-100 mmHg, ±8% of actual 101-150 mmHg, ±10% of reading Respiration Rate Range: 2-150 breaths per minute Respiration Rate Accuracy: ±1 breaths per minute EtCO2 Alarm Limits: User selectable High: 5-100 mmHg Low: 0-95 mmHg OFF Respiration Rate (RR) Alarm Limits: User selectable High: 5-150 respirations per minute Low: 0-100 respirations per minute OFF Non-Invasive Blood Pressure (NIBP) Salient Characteristics: Non-Invasive Blood Pressure (NIBP) Module option must be compatible with Zoll R Series Defibrillator. NIBP Module option must use Zoll supplied or specified cuffs, hoses and connectors. NIBP Module option be indicated for the non-invasive measurement of arterial blood pressure for resting patients in critical care and in-hospital transport. NIBP Module option must perform the following functions: Take a single blood pressure measurement Take a STAT measurement (up to 10 measurements with 5 minutes) Take repeated measurements at user-programmable intervals Immediately abort any measurement in progress by pressing one button. Set the cuff inflation pressure to adjust automatically based on the previously measured systolic value. Display systolic, diastolic and mean blood pressure on the screen. Configure alarms to go off when the unit detects blood pressure values above or below user-programmable limits. Display a history of NIBP measurement taken in the last 4 hours. Interface with strip recorder provided with the Zoll R Series Defibrillator to document events and data. Technical Specification Minimums: NIBP Measure Range (Adult Patient): Systolic: 40-260 mmHg Diastolic: 20-200 mmHg Mean: 30-220 mmHg NIBP Measurement Cycle Time: Typical: 30 seconds Maximum: 180 seconds Pulse Rate Range: 30-220 pulses per minute Alarm Limits (Adult Patient: Systolic: High: 80-260 mmHg Low: 40-140 mmHg Diastolic: High: 50-200 mmHg Low: 25-100 mmHg Mean: High: 60-220 mmHg Low: 30-120 mmHg Charging Station Salient Characteristics: Charging Station and Rechargeable Lithium Ion Battery Pack must be compatible with Zoll R Series Defibrillator. Charging Station must have a minimum of four charging bays. Charging Station must be multiple chemistry compatible. Charging Station must have a 200-watt capacity. Charging station must have a graphic driven user interface Charging station must have an RS-232 Communication port Rechargeable Lithium Ion Battery Pack must have a 5.8 Ah capacity. Rechargeable Lithium Ion Battery Pack must have high density lithium ion chemistry. Rechargeable Lithium Ion Battery Pack must have a run time (battery life) indicator Rechargeable Lithium Ion Battery Pack must be automatic calibration ready Rechargeable Lithium Ion Battery Pack must store history of use and maintenance.

Similar Contracts

Same NAICS industry code

NAICS: 334510
New
Federal
Hearing Aid Fitting and Verification for Shiprock Service Unit (IEE or ISBEE Set Aside)
Solicitation # SS-SRSU-27-0003
The Indian Health Service Shiprock Service Unit is conducting market research through a sources-sought notice to identify capable Indian-owned economic enterprises, both large and small, to provide hearing aid fitting and verification services. The primary objective is to reduce hearing aid rejection and costly remakes while ensuring patients receive optimal benefit from their devices. The requirement includes the provision of equipment with advanced technical specifications, such as dual ear capability, a frequency range of 200 to 16,000 Hz, and a comprehensive test suite including speechmap counseling and pediatric probe tube placement. Additionally, the selected vendor must provide installation and training for the Audiology Department. This opportunity is categorized under NAICS code 334510 for electronic hearing aid manufacturing. In accordance with the Buy Indian Act, the government will prioritize responses from Indian-owned economic enterprises before considering other small business set-aside programs. Interested parties must be registered in the System for Award Management and submit a company profile, a capability statement, and a completed IHS IEE Representation Form by November 03, 2026. This notice is for market research purposes only and does not constitute a formal solicitation.
Navajo Area Indian Health Svc

POSTED

1 day ago

DEADLINE

in 5 days
View Details
NAICS: 334510
New
Federal
6515--ForeSite SS Tablet w/Pressure Mapping Sensor System
Solicitation # 36C24827Q0082
The Department of Veterans Affairs, through Network Contracting Office 8, is conducting market research via a Sources Sought Notice to identify authorized sources for the ForeSite SS Tablet Pressure Mapping System manufactured by ForeSite Medical. This effort is for acquisition planning purposes and is not a formal solicitation. The required system is intended for clinical pressure assessment and treatment and must include the tablet platform, pressure-mapping sensors, sensor packs, chargers, software licenses, cables, and all necessary accessories. Key functional requirements include real-time pressure analysis and visualization, patient data storage and reporting, wireless and wired connectivity, and portable battery-powered operation. All equipment must be new and include the manufacturer's standard warranty. Interested vendors must submit electronic responses in PDF or Word format by October 30, 2026. Submissions must include the company name, address, Unique Entity Identifier, point of contact, and business size or socioeconomic status, such as SDVOSB, VOSB, Small Business, or Large Business. Additionally, respondents must provide documentation proving they are authorized to distribute or resell the ForeSite system, an estimated delivery lead time, and confirmation regarding the new condition and warranty of the product. The place of performance is located in Tampa, Florida, under NAICS code 334510.
248-NETWORK Contract Office 8 (36C248)

POSTED

2 days ago

DEADLINE

in about 20 hours
View Details
NAICS: 334510
New
Federal
Ocular Scanner
Solicitation # W91CRB-26-AWSP-Scanner-Ultrasonic-Ocular-RPP
The Portfolio Acquisition Executive Maneuver Ground Project Manager Maneuver Medical Systems is soliciting prototype proposals for a Scanner Ultrasonic Ocular device under Other Transaction Authority pursuant to 10 U.S.C. 4022. The objective is to award two prototype agreements for the delivery and demonstration of FDA-approved commercial solutions that provide anatomical visualization and diagnostic imaging of the eye, specifically for the anterior and posterior segments. Awardees are required to deliver four prototype units within 45 to 60 days of award for operational and environmental testing conducted in accordance with MIL-STD-810H. The estimated period of performance is twelve months, with awards expected around the first quarter of fiscal year 2027. The procurement utilizes a comparative best-value methodology, prioritizing technical approach, performance compliance, reliability, schedule realism, and past performance over cost. Key requirements include Trade Agreements Act compliance, MIL-STD-130N marking for hardware, and the provision of ruggedized transport cases. Deliverables encompass the hardware units, comprehensive user and maintenance manuals, cybersecurity documentation, and on-site operator training. Proposals must be submitted as four separate PDF volumes via DoD SAFE or secure email by November 12, 2026. This action is a direct Other Transaction Agreement and is not subject to the Federal Acquisition Regulation or Defense Federal Acquisition Regulation Supplement.
W6QK Acc-Apg

POSTED

2 days ago

DEADLINE

in 14 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS