Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity was posted on May 15, 2017. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

65--Heracell 150I CO2 Incubator

Awarded
VA24617Q1071Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The Department of Veterans Affairs VISN 6 Network Contracting Office is conducting market research to identify qualified Service Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, and Small Businesses capable of providing a CO2 Incubator and a 2-Stage Regulator for the Richmond VA Medical Center. The required equipment must be brand name or equal to the HERA 150I CO2 SST TC 120V and must possess FDA 510K certification for use with human patient samples. Key technical specifications include a 5.3 cubic foot stainless steel chamber, iCAN touch screen interface with historical data logging, a 90 degree Celsius moist heat decontamination routine, and a direct air jacketed heating design for rapid temperature recovery. The incubator must also feature direct humidification with a water level sensor, a choice of thermal conductivity or IR CO2 gas sensor technology, and an independent over-temperature protection system. To be considered technically acceptable, contractors must provide a letter from the manufacturer confirming they are an authorized distributor. This sources sought notice is for planning purposes only to assist the government in developing its acquisition strategy. Interested parties must submit their written capability statements to the designated point of contact by May 17 at 11:00 AM EST.

General Info

Agency

N/A

Contract Value

$6,016.2

NAICS

423450 - Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers

Place of Performance

Hunter Holmes McGuire VAMC;1201 Broad Rock Blvd.;Richmond, VA 23249 USA, VA, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Sources Sought

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
ContactsNo contacts available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Page 2 of 3 SOURCES SOUGHT: The Department of Veterans Affairs, VISN 6 Network Contracting Office (NCO) is conducting Market Research on behalf of the Richmond, VA VAMC through this sources sought to help determine the availability of qualified Service Disabled Veteran Owned Small Businesses (SDVOSB), Veteran Owned Small Businesses (VOSB), and Small Businesses (SB) to provide a CO2 Incubator and accompanying 2-Stage Regulator. Must be brand name or equal to the HERA 150I CO2 SST TC 120V. The following outlines the characteristics and features that the medical center requires: The incubator must provide a reliable, clean and easy-to-use in vitro environment, featuring proven contamination control, in which samples are secured, protected and thriving, for optimized growth and security The incubator features a 5.3 cuft. useable capacity chamber with interior components constructed of corrosion resistant, electro-polished stainless steel with rounded corners, minimizing potential for unwanted contamination. Unit shall incorporate iCAN touch screen user interface. The incubator must feature on-board graphics capability, via the iCAN controller, enabling users to obtain historical performance by parameter upon request, for user specified time periods, to allow greater research results. User interface shall also log and display all user interactions with the incubator (eg. Door openings, parameter changes), facilitating the identification of important changes in the culture environment. Internal chamber surfaces should be reduced through the elimination of unnecessary shelf or ceiling panels, bolts, air ducts or screws which provide an opportunity for difficult to clean, hidden contamination. Plastic components shall not be incorporated within the culture chamber. The incubator must incorporate exclusive ContraCon high temperature decontamination routine, which subjects the culture chamber interior and its components to a 90°C moist heat disinfection cycle which has been proven effective in contamination control against bacteria, molds, fungal spores and mycoplasma. Decontamination routine must avoid the limitations and potential hazards associated with UV germicidal lamps, and be capable of running without the need to disassemble and remove any sensors, hardware or other components within the chamber, as their subsequent re-installation offers the potential for the introduction of contamination, thus neutralizing the intended benefit in simplifying cleaning routines and eliminating variability in decontamination procedures. The incubator shall feature a 26 width, 35 height and 31 depth and reversible door swing, to conserve valuable laboratory space and maximize flexibility of placement within a variety of laboratory environments. Units should be readily stackable without the need for tools, additional hardware or thermal barriers To provide superior temperature uniformity and recovery times with reduced servicing and maintenance concerns, the unit must incorporate a direct air jacketed heating design featuring high quality thermal jacket insulation and fan assisted circulation allowing recovery under 10 minutes following a typical 30 second door opening, The incubator must incorporate a direct humidification design, in which internal water reservoir is in direct contact with a heated surface to maximize humidification efficiency, as opposed to water pans or trays which impede heat transfer and optimal humidity characteristics. Unit must feature a water level sensor and alarm to alert user when humidification water refill is required. Direct humidification allows for the fastest recovery possible of up to 95% humidity conditions within incubator following door openings, which is required for optimal cell growth and elimination of dehydration caused by evaporation Unit shall be available with a choice of either thermal conductivity or IR CO2 gas sensor technology. Sensor must be mounted directly within the culture chamber, and have recovery rates of under 5 minutes following routine 30 second door opening, as opposed to sensors located outside the culture environment requiring complicated and inefficient by-pass systems, and those relying upon gravity convection for circulation of environmental conditions. A fully automatic Auto Start routine shall be incorporated to reliably calibrate and verify proper operation of all electronic measuring systems, within a few hours, simplifying incubator set-up and speeding availability for culturing use. The incubator must include an independent over-temperature protection function with independent temperature sensor, to protect valuable cultures from potential damage in the event of an unexpected failure in the primary temperature control system. The incubator must offer a direct access port on the interior incubator door to enable comparative CO2 measurement by an external device. This allows for improved accuracy in the collection and measurement of CO2 to validate primary system readings, and simplification of the process. Incubator must have FDA 510K certification, representing its suitability for use with human patient samples. If the contractor is capable of providing the above items, the contractor shall provide a letter from the manufacturer stating they are an authorized distributor for their products. Failure to submit an authorized distributor letter shall result in the product(s) potentially offered to be considered grey market and shall not be considered technically acceptable. The capability statements received from this market research are for planning purposes only and will assist the Government in planning its acquisition strategy. This is strictly market research and the Government will not entertain questions concerning this market research. The Government will not assume any costs incurred by the contractor in the preparation of responses. All responses shall be submitted in writing no later than May 17, 11:00 AM, EST to the attention of: Cole J. Culley, VA Medical Center, 27 Averill Avenue, Hampton, VA 23667. E-mail address: contact@example.gov

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS