65--Starburst Talon Electrode

Awarded
VA24112R0749Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The VA Healthcare System intends to enter into a sole source contract with Angiodynamics for the procurement of Starburst Talon Semiflex Electrodes and Thermo Dispersive Electrode Pads. This acquisition, conducted under FAR 6.302-1, specifies a requirement for five units of each product. The Starburst Talon Semiflex Electrode is characterized by its hybrid rigid and flexible trocar sections, allowing for 90-degree bending for CT gantry entry and precise placement via a visible active tip. It utilizes infusion-based radiofrequency ablation to achieve fast spherical ablation with real-time temperature feedback. The accompanying thermo dispersive pads are designed for use with the 1500X RF generator, featuring integrated thermocouples that provide continuous temperature monitoring at the adhesion site to automatically shut off power if unsafe temperatures are detected. This notice serves as a sources-sought inquiry to determine if competitive procurement is necessary. Interested parties were required to submit supporting literature to the Contracting Officer by May 23, 2012, to challenge the sole source determination.

General Info

Agency

N/A

Contract Value

$13,914.54

NAICS

423450 - Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers

Place of Performance

Department of Veterans Affairs;1400 VFW Parkway;West Roxbury, MA 02132 USA, NY, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Sources Sought

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
ContactsNo contacts available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
The VA Healthcare System intends to negotiate on a sole source basis pursuant to FAR 6.302-1 -- Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements with Angiodynamics for Starburst Talon Semiflex Electrodes and pads. This requirement will include the following characteristics: Product Description Product # 700-102845 Starburst Talon Semiflex Electrode- Qty 5 each Product # 700-102649 Thermo Dispersive Electrode Pad (set of 2)- Qty 5 ea Salient Characteristics The StarBurst Talon Semi-Flex RFA electrode is a versatile device that features both rigid (metal) and flexible (polymer) trocar sections. The device offers all the benefits of the StarBurst Talon RFA electrode, but also has the ability to bend up to 90 degrees in all directions allowing for easy entry into the CT gantry. The active tip is also visible under CT imaging for precise placement. Features " Fast 4 cm spherical ablation in an average of 11 minutes using Innovative Infusion-Based RFA which overcomes the limitations of traditional dry electrodes " Surgically tapered cutting tip to penetrate and anchor soft tissue tumors " Single device placement for surface or difficult-to-reach lesions " Proprietary, real-time temperature feedback from all four electrode tines ensures controlled ablations and predictable outcomes New temperature monitoring thermo pads help the physician monitor the temperature of the return pad site during the ablation process. AngioDynamics' pads feature continuous temperature monitoring at the pad adhesion site through the incorporation of a thermocouple device located at the pad leading edge. The pads are designed to meet the needs of clinicians using AngioDynamics' latest generation of high-power, infusion based radiofrequency electrodes. The thermocouple returns data automatically to the 1500X RF generator, monitoring pad temperature throughout the procedure, and shutting off power when unsafe pad temperatures are detected. Thermo pads will work with any existing 1500X System. This Notice of Intent is NOT a request for competitive proposals. Parties may identify their interest, accompanied by supporting literature, to the Contracting Officer no later than May 23, 2012 4PM EST. Responses should be sent to contact@example.gov. Information received will be for the purpose of determining whether or not to conduct a competitive procurement. The determination to conduct a competitive procurement based on responses to this notice is solely within the discretion of the Contracting Officer.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS