This Sources Sought opportunity from Department Of Veterans Affairs was posted on July 7, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
6515--688 - XSensor Wheelchair Pressure Mapping System (VA-26-00075290)
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
The U.S. Department of Veterans Affairs is seeking information through a sources-sought notice for a Brand Name or Equal XSensor and ForeSite SS Wheelchair Pressure Mapping System to be delivered to the Washington DC VA Medical Center. The required equipment includes a ForeSite SS Tablet with preinstalled software, two X4 Sensor Packs containing one LX100:36.36.02 and one LX100:40.40.02 pressure mapping sensor, a USB key with desktop software and user guide, micro-USB to USB cables, a dual USB hub, a carry case, and necessary chargers. The sensors must feature a 50.8 cm x 50.8 cm and 45 cm x 45 cm sensing area respectively, with 12.7 mm resolution, 1,600 sensing points, and a pressure range of 5-200 mmHg. The system must be CSA/CE Class 1 ISO 60601-1 compliant, support Bluetooth and wired connectivity, and include secure features such as password protection and encrypted patient data. All equipment must be sourced through manufacturer-approved channels and covered by manufacturer warranty, with distributors required to provide documentation verifying authorized distribution status. Responses must include full company details, DUNS/CAGE/SAM UEI, business size, manufacturer or distributor identification, country of origin, technical literature proving equivalency to the specified brand-name product, and an authorized distributor letter certified by the OEM. While responses do not constitute offers or binding proposals under FAR 15.201(e), the government may contact respondents for additional information. Equipment delivery must occur within 14 days of any future contract award, during normal business hours at the specified Washington DC location, with prior approval required for any non-standard delivery access points. The notice is purely for planning purposes, with no solicitation yet issued, and no evaluation results or feedback will be provided to respondents. Any procurement resulting from this RFI will be announced separately, and no obligation is created by responding. Submissions are due by July 14, 2026, and all proprietary information will be handled with confidentiality.
General Info
Agency
NAICS
Place of Performance
Department of Veterans Affairs VAMC, Washington, MD, 20422Set-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
SCOPE OF WORK -Vendor will provide all equipment necessary to meet the Statement of Work below.
STATEMENT OF WORK PART B WORK REQUIREMENTS
B.1 TO BE PROVIDED: The procurement is for a Brand Name or Equal XSensor and ForeSite SS Wheelchair Pressure Mapping System. All items must be covered by manufacturer s warranty and procured through a manufacturer-approved distribution channel. Distributers and resellers must be able to document ability to provide items through manufacturer-approved distribution channels upon request.
Specifications. 4.1 Equipment
Line Item Description Quantity SYS-01-00100 ForeSite SS Tablet + 2 LX100:36.36.02 (X4) 1 ASY-01-00164 LX100:40.40.02-X4, Pressure Range: 5-200 mmHG (0.1 3.9 psi) 1
4.2 Required Features 1 ForeSite SS Tablet (with charger) 2 X4 Sensor Pack (with charger) 1 USB Key to include: ForeSite SS Desktop Software User Guide 2 Mico-USB to USB Cable (to allow for a wired connection) 1 Dual USB Hub 1 Carry Case 1 LX100:40.40.02 Sensor Sensing Area: 50.8 cm x 50.8 cm (20 x 20 ) Resolution: 12.7 mm (0.5 ) Sensing Points: 1,600 Pressure Range: 5-200 mmHg 1 LX100.36.36.02 Sensor Sensing Area: 45 cm x 45 cm (18 x 18 ) Resolution: 12.7 mm (0.5 ) Pressure Range: 5-200 mmHg
This system is a CSA/CE Class 1 ISO 60601-1 medically approved product. The ForeSite SS Tablet comes with preinstalled ForeSite SS software and is intended as a secure, easy-to-use, pressure mapping specific device. This system is intended for clinicians in a hospital setting who require secure devices with user password protection, encrypted patient files, and the ability to pressure map without cables connecting the Tablet to the sensor. The sensors come connected to the X4 Sensor Packs and have the option to transmit data to the ForeSite SS Tablet via Bluetooth (alternatively, you have the choice to use the system via a wired USB connection). High resolution sensors are critical to seeing surfaces pressures and making informed recommendations.
STATEMENT OF WORK PART C SUPPORTING INFORMATION
C.1 Place of Performance Washington DC VA Medical Center located at 50 Irving St NW, Washington, DC 20422. Delivery vehicles shall keep traffic disruptions to a minimum. Use of any other entry points must be approved by Chief, Engineering Service prior to use. Vendor shall deliver required parts or equipment specified above during approved work times.
C.2 Period of Performance Vendor will provide equipment within 14 days of contract award. Approved work times for this job shall be normal working hours of 8AM 430PM The Contractor shall perform all services during normal business hours.
RESPONSES:
Please include descriptive literature demonstrating the product meets or exceeds the brand name product specified above.
Please provide any product solution or configuration so long as they are equivalent to the brand name product.
Responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.
PLEASE PROVIDE THE FOLLOWING ADDITIONAL INFORMATION:
Full name and address of company
DUNS number/ CAGE Code/ SAM UEI
Business Size
Manufacturer or Distributor
If distributor, provide full name, business size, and address of manufacturer.
Country of Origin designation for all products.
Technical Literature that clearly shows product(s) are equivalent.
Any additional product solution or configuration that would be beneficial to the functionality of the product line identified.
Authorized Distributor Letter Certified by OEM with a current date.
Although not required, vendors responding to this Sources Sought may also submit a Capabilities Statement. DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
More opportunities from Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS
