This Sources Sought opportunity from Department Of Veterans Affairs was posted on August 25, 2020. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6515--APPLIED BOISYSTEMS 3500XL GENETIC ANALYZER INSTRUMENT BRAND NAME OR EQUAL

Closed
36C25620Q1101Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

Michael E DeBakey VA Medical Center 2002 Holcombe Blvd Houston, TX, MS, 77030, USA

Set-Aside

SDVOSBC

Documents

1

36C25620Q1101.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 256-NETWORK Contract Office 16 (36C256)
Contacts1 person available
OfficeRIDGELAND, MS, 39157, USA
Office AddressRIDGELAND, MS, 39157, USA
Contacts
Ayanna S HamiltonAyanna Hamilton

Full Description

Show more
Department of Veterans Affairs Network Contracting Office 16 - HOUSTON In Support of the Michael E. DeBakey VA Medical Center (MEDVAMC) REQUEST FOR INFORMATION 36C25620Q1101 BACKGROUND: MEDVAMC has a requirement for the following: REQUIREMENTS: Applied Biosystems 3500XL Genetic Analyzer or EQUIVALENT as listed below: BACKGROUND: The Michael E DeBakey VA Medical Center (MEDVAMC) has a request to purchase Applied Biosystems 3500XL Genetic Analyzer Instrument brand name or equal. The Applied Biosystems 3500XL Genetic Analyzer will be used for HIV genotype testing currently being done in Microbiology and will be replacing EE # MX#1173841, Applied Biosystems 3130X Genetic Analyzer, which is no longer being supported by the industry. The contractor shall furnish all labor, materials, parts, equipment, tools, transportation, and supervision to provide, install at, the Michael E. DeBakey VA Medical Center (MEDVAMC), 2002 Holcombe Blvd, Houston, Texas 77030. The Contractor shall provide all necessary training to the designated VA employees on how to use the installed equipment/products after the installation and setup were complete. All equipment shall be brand new, and all work shall be done in a first-class manner. The contract price shall be firm-fixed, all-inclusive not limited to specified products/equipment, installation, setup/configuration, and training on how to use the installed products/equipment. Salient Characteristics: A new Applied Biosystems 3500xL Genetic Analyzer with the following requirements and key features which will be used for HIV genotype testing. Suggested Manufacturer Brand Name; Applied Biosystems 3500xL Genetic Analyzer or EQUIVALENT as listed below: Specifications/Salient Characteristics: Must process multiple runs with up to 8 samples per run Must be a fully automated system with polymer loading and replacement, DNA separation, detection and data analysis to generate base-called or size-called results. Must be a Capillary electrophoresis instrument Must be designed for use with 8-tube Standard or Fast strips as well as 96 well Standard and Fast strips Samples must be able to be automatically injected directly from the 96 well Microtiter plates or 8-strip tubes Must be designed to specifically improve temperature control and be able to maintain temperatures from 18 to 70 degrees C Must be designed with pre-packaged, single use consumables as shown below: Performance Optimized Polymers ((POP-4®, POP-6®, POP-7 ) available in ready-to-use, load and run, pouch format. Pouches available in three sizes: 96 samples, 384 samples and 960 samples Conditioning Reagent Consumables available in ready-to-use load and run, pouch format. It will contain enough reagents for a single use only Cathode Buffer Container available as a pre-filled container with 1X buffer with two separate compartments; the left side with cathode buffer for electrophoresis and the right side with spent polymer waste from capillary wash between injections Anode Buffer Container available as a pre-filled container with 1X buffer, with a primary chamber containing buffer and a secondary overflow chamber Key Features: 24-capillary 3500xL System Advanced thermal system design that improves temperature control for demanding DNA fragment analysis applications Single-line 505 nm, solid-state long-life laser that utilizes a standard power supply and requires no heat removal Signal uniformity from instrument to instrument, run to run, and capillary to capillary Must have a powerful, integrated data collection and primary analysis software that provides real-time assessment of data quality Radio Frequency Identification (RFID) technology to track key consumables data and records administrative information Must have advanced multiplexing capabilities for DNA fragment analysis with up to six unique dyes Must have simple setup, operation, and maintenance 24-capillary (3500xL system) array and polymer DNA Sequencing, Fragment Analysis and/or HID reagents Dell computer workstation with flat-screen monitor Integrated software for instrument control, data collection, quality control, and auto analysis of sample files for base calling and fragment sizing DELIVERY REQUIREMENTS: Deliver to room # 3A-211. Monday through Friday between 0800 & 1630. REQUESTED RESPONSES: The intent of this Request for Information is to establish sources to define the procurement strategy (e.g set-aside, sole source, unrestricted) for a solicitation that VA intends to post soon. Interested contractors are requested to respond in accordance with the following: Please respond to this RFI if you can provide the exact brand name products listed in the table in the background section above. In the response please cite your business size status. If you have an existing GSA or VA, Federal Supply Schedule contract, please include the contract details in your response. DISTRIBUTORS: You must provide proof that you are an authorized distributor. VA does not accept grey market items. Please respond to this RFI if you can provide supplies that may be determined EQUIVALENT to the products listed in the table in the background section above. Please provide details on the proposed EQUIVALENT products such as Manufacturer Name, Part Number, and Description. If you have an existing GSA or VA, Federal Supply Schedule contract, please include the contract details in your response. DISTRIBUTORS: You must provide proof that you are an authorized distributor. VA does not accept grey market items. Please note that VA is particularly interested in determining the availability of Small Business Manufacturers. If your company is a small business manufacturer of potentially equivalent items, please respond to this RFI. Vendors are requested to submit estimated market research pricing with their responses. The estimated pricing will be considered when determining the procurement strategy for the future solicitation. (e.g. if CO determines that capable small businesses cannot provide fair and reasonable pricing, then the solicitation will not be set-aside). Please note that if no responses to this notice are received, from either authorized distributors of the cited brand name nor from manufacturers marketing a potentially equivalent brand, then this action will be sole sourced to the manufacturer cited in the Background section above. CONTACT INFORMATION AND RESPONSE DUE DATE: Please email all responses to contact@example.gov. Please respond to this RFI no later than 08/31/2020. DISCLAIMER: This RFI is issued solely for informational and planning purposes and does not constitute a solicitation. Responses to this notice are not offers and cannot be accepted by the Department of Veterans Affairs to form a binding contract. Respondents are solely responsible for all expenses associated with responding to this RFI.

More opportunities from Department Of Veterans Affairs → 256-NETWORK Contract Office 16 (36C256)

Same awarding agency

NAICS: 238290
New
Federal
N099--JLM Roll Up Door Replacement
Solicitation # 36C25627Q0092
Solicitation 36C25627Q0092 is a combined synopsis and request for quote issued by the Department of Veterans Affairs for the replacement of a motorized roll-up door at the John L. McClellan Veterans Hospital. This is a 100% set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 238290. The project requires the contractor to provide all labor, tools, and equipment, including a scissor lift and forklift, to remove and dispose of the existing door and install one grey 7 by 9 foot motorized rolling steel rapid slat door with insulated slats and an obstruction safety device. The award will be a firm-fixed-price contract with a performance period of 30 days from the Notice to Proceed and includes a one-year warranty. The government will utilize the Lowest Price Technically Acceptable (LPTA) evaluation process, focusing on technical capability, price reasonableness, and the completion of the VA Notice of Limitations on Subcontracting. Interested offerors must submit a three-volume quote package consisting of technical capabilities, a completed price schedule, and the required VAAR certification. Quotes must be emailed to Joseph Warren by 3:00 PM CST on November 18, 2026. A site visit is scheduled for November 6, 2026, at 10:00 AM, and all inquiries must be submitted by November 10, 2026. Performance will take place at the Central Arkansas Veterans Healthcare System in North Little Rock, Arkansas, and contractors must comply with all OSHA, ANSI, CAN, and UL standards.
Other Building Equipment Contractors

POSTED

about 15 hours ago

DEADLINE

in 20 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS