This Special Notice opportunity from Department Of Veterans Affairs was posted on February 26, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
6515--Bronchoscopes Intent to Sole Source
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
General Info
Place of Performance
FLSet-Aside
Documents
1AI Contract Breakdown
Uniform Contract FormatSign up to view the full breakdown with detailed analysis of each section.
View Full BreakdownThis one is closed. Find the next one like it.
Open contracts like this one, right now:
- Surgical Suction Apparatus SupplierOpen now, due in 6 days
- Bipolar Monopolar Cables & ForcepsOpen now, due in 10 days
Ask CLEATUS
I've read this contract. Ask me anything.
Timeline
Submission Closed
Organization & Contact Information
Full Description
STATEMENT OF NEED
GENERAL: The Bronchoscopy Section Pulmonary Department of Medicine Services at James A. Haley Veterans Hospital, 13000 Bruce B. Downs Blvd, Tampa, Florida 33612, has a requirement for replacement Olympus BF-UC190-A ultrasound bronchoscopes. BACKGROUND: The Bronchoscopy Section Pulmonary Department of Medicine Services at James A. Haley Veterans Hospital, 13000 Bruce B. Downs Blvd, Tampa, Florida 33612, has a requirement for replacement Olympus BF-UC190-A ultrasound bronchoscopes. The currently used BF-UC180F ultrasound bronchoscopes are at end-of-life, and Olympus is coming to an end to their support of this model. PURPOSE: These scopes are used in the Bronchoscopy procedure rooms to provide video imaging during bronchoscopy procedures. SCOPE: James A. Haley VA Hospital is requesting contractors provide brand name only equipment that meets the physical, functional and performance of the listed salient characteristics in this section. The equipment features are essential to the technical requirements to meet the needs of the government. SALIENT CHARACTERISTICS: Must be compatible with current video processing system (Olympus) used in all suites Must be able to be cleaned and reprocessed using the current equipment owned by SPS Provides enhanced access and control to allow staging and diagnosis of even difficult-to-reach lymph nodes and lesions. Real-time ultrasound imaging enables direct visualization of the ViziShot 2 EBUS-TBNA needle as it penetrates the lymph node. This facilitates correct capsule-to-capsule technique, which helps to optimize sample collection, and provides clearer procedural views: an integrated water jet channel helps maintain clear views during procedures The uniquely designed compact distal tip of the BF-UC190F and increased scope angulation enhances maneuverability with better access to difficult-to-reach lymph node stations in the mediastinum (4L) and in the hilum (10R). A decreased forward oblique angle of 20° facilitates easier endoscopic orientation and allows the operator to keep the endoscopic image in full field of view while navigating the airways during a procedure. Dual Focus allows the user to select between two focus settings. A steeper needle puncture angle provides a more perpendicular needle orientation toward the target allowing for smoother target penetration between cartilage rings and other critical vessels. An improved endoscopic image with higher resolution provides better visualization in the airway to accurately identify anatomy landmarks and detect abnormalities. Wider/Increased Viewable Angle: Wider the field of view to attain an increase viewable distance. The power of the EVIS EXERA III platform expands across the hospital to enable equipment standardization and simplified support and service, with the ultimate goal of lowering the total cost of equipment. The BF-UC190F has a working channel of 2.2 mm that is compatible with a full line-up of Olympus EBUS-TBNA needles which are designed to deliver outstanding performance while minimizing channel damage, thereby potentially reducing repair costs and extending endoscope life. TRADE: Trade-in value will be provided in for Olympus BF-UC180F ultrasound bronchoscopes currently on hand. Serial Numbers as follows: 7621602; 7621606; 7621611; 7621612. SOFTWARE: Compatibility with EndoSoft/ProvationMD softwares, and CPRS/Vista. TRAINING: Government will not require additional training. WARRANTY OF EQUIPMENT: Government requirement for standard manufacturer industry warranty term. Government does not accept extended warranty, which requires advance payment. DELIVERY SCHEDULE: All items to be delivered and installed within 30 days of receipt of purchase order, and no later than 4/30/2026. PLACE OF Delivery: James A. Haley Veterans Hospital, 13000 Bruce B. Downs Blvd. Bldg 1, Tampa, Florida 33612, between 8:00AM to 4:30PM. Delivery during the Holiday will not be accepted.
More opportunities from Department Of Veterans Affairs → 248-NETWORK Contract Office 8 (36C248)
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS