This Award Notice opportunity from Department Of Veterans Affairs was posted on January 13, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
6515--Laparoscopic Probes
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
The Department of Veterans Affairs Network Contracting Office 8 awarded contract 36F79718D0321 to Marathon Medical Corporation for the procurement of laparoscopic probes and a console to replace end-of-life equipment at the C.W. Bill Young Veterans Medical Center in Bay Pines, Florida. The total award value is $155,183.31. This procurement was conducted as a name-brand-only requirement under the Federal Supply Schedule and was set aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 339112. The contract requires the delivery of one Neoprobe Console Model 2400 (P/N: NPCU4), one AC power cord (P/N: NPA75), three straight 14mm probes (P/N: NPB14S), and three angled 14mm probes (P/N: NPB14A). The equipment must be FDA 510(k)-cleared and specifically designed for Tc-99m radiotracer detection during intraoperative sentinel lymph node mapping. Key technical specifications include Bluetooth wireless connectivity, real-time audible and numerical output, and probes that are surgical-grade and autoclavable to withstand repeated sterilization cycles. Delivery and acceptance are designated for the Surgery Service at Building 100, routed through Warehouse Building 36 in Bay Pines, Florida, with a required delivery date of January 20th. The award includes a mandatory minimum one-year manufacturer warranty with U.S.-based service support. Performance is measured by the system's ability to maintain a minimum detection sensitivity of 10 CPS and ensure secure, calibrated wireless pairing between the console and probes.
General Info
Contract Value
$155,183.31Place of Performance
FLSet-Aside
Awardee
MARATHON MEDICAL CORPORATIONAward Issued Date
Documents
2AI Contract Breakdown
Uniform Contract FormatSign up to view the full breakdown with detailed analysis of each section.
View Full BreakdownThis one is closed. Find the next one like it.
Open contracts like this one, right now:
- Intraosseous Infusion System SupplierOpen now, due in 6 days
- Yankauer Suction Instrument ManufacturingOpen now, due in 6 days
Ask CLEATUS
I've read this contract. Ask me anything.
Timeline
Organization & Contact Information
Full Description
Equipment Requirement: Minimum Required Features and Specifications Console Requirements Must be a handheld gamma detection system designed for intraoperative sentinel lymph node mapping. Must include real-time gamma detection with both audible and numerical output. Must provide Bluetooth or equivalent wireless connectivity between console and probes. Must include an onboard self-calibration function for probe compatibility and accuracy. Must display counts-per-second (CPS) or equivalent measurement in real time. Must have adjustable audio tone that increases with radiotracer uptake. Must operate using Tc-99m radiotracer detection. Must have adjustable sensitivity ranges, thresholds, and audio volume. Must include internal quality control and diagnostic checks. Must be portable, ergonomic, and suitable for sterile OR environments. 5.2. Probe Requirements (Straight & Angled) Probes must be surgical-grade, autoclavable, and able to withstand routine SPS sterilization. Must include high-sensitivity solid-state detector crystal suitable for Tc-99m detection. Must be available in 14mm straight and 14mm angled configurations. Must provide directional shielding to minimize background activity. Must be ergonomic for precise navigation during surgery. Must include Bluetooth wireless connectivity to the parent console. Must be fully compatible with the console s calibration system. 5.3. Wireless & Calibration Requirements Console and probes must pair using secure, low-latency wireless technology. Wireless signals must support real-time detection feedback without delay. System must automatically perform probe verification and calibration on startup. System must limit pairing to validated, manufacturer-approved probes. 5.4. Performance Requirements Must detect Tc-99m radiotracer signal with high sensitivity for sentinel lymph node biopsy. Must offer rapid signal acquisition ( 10 CPS minimum detectable signal or better). Must provide stable reading even when handheld or repositioned. Must support cancer-related procedures requiring gamma detection. Must maintain accuracy and repeatability over the device s lifespan. 5.5. Sterilization & Infection Control Probes must be fully autoclavable. Must withstand repeated SPS sterilization cycles without loss of sensitivity. Must meet VA infection control standards for OR-use devices. 5.6. Safety Requirements System must meet FDA-cleared (510k) requirements for gamma detection. Console must include overload protection, low-battery alerts, and functional test features. All components must include manufacturer documentation for safe handling and OR use. 5.7. Power & Accessories Consoles must operate using OR-compatible power supply. Must include an AC power cord compatible with U.S. outlets. Must include necessary accessories such as charger, base unit, or equivalent. 5.8. Warranty & Support Must include a minimum 1-year manufacturer warranty on console and probes. Vendor must provide U.S.-based service, replacement parts, an
More opportunities from Department Of Veterans Affairs → 248-NETWORK Contract Office 8 (36C248)
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS