Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on March 21, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6515--MAKO ROBOTIC ARM SYSTEM

Closed
36C25024Q0456Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

Louis Stokes Cleveland VAMC 10701 East Blvd., Cleveland, OH, 44106

Set-Aside

NONE

Documents

1

Sources Sought Notice 36C25024Q0456 - Mako Robotic Arm System

DOCX, Low prioritysources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)
Contacts1 person available
OfficeDAYTON, OH, 45428, USA
Office AddressDAYTON, OH, 45428, USA
Contacts
Rachelle HamerRachelle J. Hamer

Full Description

Show more
Mako Robotic Arm System This is a Sources Sought (SS) Notice only; it is not a Solicitation (i.e., Request for Proposal, Request for Quotation, or Invitation for Bids.), This SS is part of the Government s market research effort to determine the scope of industry capabilities and interest and will be treated as information only. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responses to this SS are strictly voluntary and the Government will not pay respondents for information provided in response to this SS. Responses to this SS will not be returned and respondents will not be notified of the result of the review. Although responses to the questions posed by the Government would be most beneficial to this market research effort. The purpose of this SS is to conduct Market Research to determine an acquisition strategy, to include determining if there are a sufficient number of Small Businesses capable of performing the requirements to warrant a set-aside, for the procurement of bronchoscopes at the Louis Stokes Cleveland VA Medical Center (CLE VAMC), 10701 East Blvd., Cleveland, OH 44106. Mako SmartRobotics possesses several key features that differentiate it from other surgery platforms. After a thorough surgical plan is created and approved by the surgeon, the Mako System assists surgeons with executing that plan using AccuStop haptic technology. The implant position, tracking and soft tissue balancing are assessed in a virtual 3D model by combining a preoperative CT and intraoperative bone registration. A CT scan uses a combination of 2D and digital geometry processing to generate a 3D image of the body. While plain film radiographs (X-rays) provide a 2D image of the scanned area, anatomic structures may overlap, creating an image which is less detailed than a CT scan. In a CT image, overlapping structures are eliminated, making the internal anatomy easier to visualize. In knee and hip arthroplasty procedures, the femoral version and tibial torsion76 can provide critical guidance when planning a case. Bony anatomic landmarks of the femur and tibia can be clearly identified using 3D imaging technologies. After the surgeon assesses implant size and position in the preoperative plan, the robotic arm is introduced to the surgical site. The robotic arm uses AccuStop haptic technology to help ensure only the desired bone is resected. The robotic arm will give resistance, an audible warning and ultimately turn off if the surgeon attempts to move the cutting tool on the robotic arm outside the boundaries created in the preoperative plan. Potential sources must demonstrate the capability to provide the required equipment. Potential sources should submit: Point of Contact with email address and phone number; Business name and address; Applicable business socio-economic category; GSA, NAC, TAC, or SAC contract number if applicable; Capability statement and/or brochures of the equipment to allow for assessment of meeting the requirements stated above; SAM UEI number; Delivery days After Receipt of Order (ARO); What country made the product is made in; and Whether or not your company is the OEM or a distributor. If a distributor, indicate who the OEM is and provide authorized distributor letter. Letter from Olympus America, Inc. stating compatibility. Proprietary/Competition Sensitive information (appropriately marked) will be protected from disclosure to the greatest extent practical, however it is preferred that respondents do not provide proprietary or otherwise restricted responses unless they are indicating proprietary technical characteristics. Vendors are hereby notified that if a competitive solicitation is issued on the Beta SAM website http:// https://sam.gov at a later date, all interested parties must respond to that Solicitation announcement separately from any response to this SS announcement. This SS does not restrict the Government's acquisition approach on a future Solicitation. No faxes, courier delivered, or telephone inquiries/submissions will be accepted. Responses should be submitted to Rachelle J. Hamer, Contracting Officer at contact@example.gov, by Thursday, March 28, 2024, by 5PM ET. Enter RFI 36C25024Q0456| Mako Robotic System in the email subject line.

More opportunities from Department Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)

Same awarding agency

NAICS: 541380
New
Federal
Effluent Wastewater Testing - Saginaw VAMC
Solicitation # 36C25027Q0032
The Department of Veterans Affairs Network Contracting Office 10 is soliciting a firm fixed price contract for wastewater effluent laboratory analysis services at the Aleda E. Lutz VA Medical Center in Saginaw, Michigan. This procurement is a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 541380. The scope of work requires the contractor to provide all labor, equipment, and supervision for the preparation, collection, storage, and transportation of wastewater effluent samples, as well as the performance of analytical testing and the provision of consultative services. All analysis must comply with 40 CFR Part 136, with specific requirements for PCB testing per the City of Saginaw Total PCB Minimization Program and mercury testing per Method 245.1. Formal analytical reports must be delivered to the facility GEMS Coordinator within seven business days of sampling. To be eligible for award, offerors must demonstrate at least three years of experience in wastewater effluent laboratory testing and one year of experience in sample collection, storage, and transportation. Additionally, a signed certification regarding limitations on subcontracting is mandatory for evaluation. The contractor is required to maintain a Quality Assurance Program and adhere to OSHA safety standards, as well as the City of Saginaw Code of Ordinances and Northwest Utilities Authority regulations. Performance is scheduled to begin on December 1, 2026, with invoicing submitted semi-annually or upon completion of service. The government will monitor performance based on turnaround times, customer service responsiveness, and the accuracy of quality control results.
Testing Laboratories and Services

POSTED

1 day ago

DEADLINE

in 7 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS