6515--NX EQ Image Guided Surgical Navigation System

Closed
36C10X26Q0242Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334510
New
Federal
Automated Ultrasound-Based, Super Intelligence (SI)-Enabled Fracture Detection
Solicitation # BARDA-FY27-10192026
The Center for Biomedical Advanced Research and Development Authority (BARDA) has issued Sources Sought Notice BARDA-FY27-10192026 to identify innovative medical countermeasure technologies for the rapid triage of musculoskeletal injuries, such as fractures and soft tissue injuries of extremities. This request for information is intended for planning and market research purposes to assess commercially available or nearing-commercial technologies that utilize Super Intelligence (SI) and machine learning for automated ultrasound-based fracture detection. The goal is to find standalone, point-of-care devices that can operate in emergency departments, urgent care centers, and austere field settings without relying on traditional imaging infrastructure like X-ray or CT scans. The desired technology must feature automated volumetric capture, 3D-rotatable modeling, and SI-enabled image processing that outperforms human imaging experts and has undergone FDA 510k clearance processes. BARDA is interested in ruggedized, portable units with sufficient battery life for disaster response, interoperability with electronic health record systems, and minimal training requirements for non-specialist operators. Potential acquisition strategies being explored include direct purchases, leases, or vendor-managed inventory arrangements. Interested small businesses and other than small business concerns under NAICS code 334510 must submit their capabilities statements by 1:00 p.m. Eastern Time on November 18, 2026. Submissions must include separate Technical and Business Representation sections, each limited to 10 pages in 12-point Times New Roman font, and be emailed to Justin Moore and Richard Hall. Responses should detail the company's manufacturing capabilities within the United States, regulatory maturity, supply chain resilience, and cybersecurity standards for handling sensitive patient health information.
Barda - Aspr / Daappo / Barda Dcma

POSTED

about 23 hours ago

DEADLINE

in 28 days

AI Contract Overview

Show more

The Department of Veterans Affairs is conducting market research through a Sources Sought Notice to identify qualified providers capable of supplying Medtronic Stealthstation Image-Guided Surgical Navigation Systems or equivalent equipment on an agency-wide basis. The government intends to award a single Requirements Contract with Firm-Fixed Price orders for a base period of 12 months, with four additional one-year option periods. The equipment must support cranial neurosurgery and spine applications, feature a minimum 27-inch high-resolution touchscreen, provide optical and EM tracking, and be interoperable with the VA Electronic Health Record System. Interested vendors must be registered in the System for Award Management under NAICS code 334510 and submit their responses by August 26, 2026. Submissions must include technical literature demonstrating compliance with all salient characteristics, pricing information, and details regarding manufacturer warranties and service plans. This notice is for planning purposes only and does not constitute a formal solicitation or a commitment to award a contract.

General Info

VA seeks providers for Medtronic Stealthstation or equivalent surgical navigation systems agency-wide.

NAICS

334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing

Place of Performance

Nationwide, MD

Set-Aside

NONE

Documents

1

Sources Sought Notice for NX EQ Image Guided Surgical Navigation System - 36C10X26Q0242

DOCX, High priority: read this firstsources-sought
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → Sac Frederick (36C10X)
Contacts1 person available
OfficeFREDERICK, MD, 21703, USA
Office AddressFREDERICK, MD, 21703, USA
Contacts
Alanna WilsonContract Specialist

Full Description

Show more
1.0 DESCRIPTION THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The Department of Veterans Affairs (VA) Enterprise Procurement Office (EPO), formerly the Strategic Acquisition Center (SAC), is issuing this Sources Sought Notice as a means of conducting market research to identify qualified sources with the capability and the resources to meet the Veterans Health Administration s (VHA) Non-Expendable Equipment National Program requirement for Image-Guided Surgical Navigation Systems. The EPO in conjunction with VHA is seeking a qualified source to supply brand name or equal Medtronic Stealthstation Image-Guided Surgical Navigation System on an agency-wide basis. VA intends to award a single Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contracts, to a supplier of this equipment. Vendors will be required to deliver complete image-guided stereotactic systems to VA medical centers and facilities throughout the United States. The anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The associated North American Industrial Classification System (NAICS) code for this procurement is 334510 Electromedical and Electrotherapeutic Apparatus and the associated size standard is 1,250 employees. The FAR Provision found at 52.204-7 requires that The Offeror shall have an active Federal Government contracts registration in the System for Award Management (SAM) when submitting an offer or quotation. You may access the SAM website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://www.sba.gov/veterans/#vetcert at the time of submission. Submissions for this sources sought shall be submitted by email no later than August 26, 2026, 12:00pm Eastern to all the following: Alanna.Wilson@va.gov Sara.Vickroy@va.gov This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time. 2.0 SCOPE OF WORK The Image-Guided Surgical Navigation System is a stereotactic computer-aided surgical system designed to aid in the performance of minimally invasive procedures by combining medical imaging, dedicated computer software, and instrument tracking systems for guidance. The systems provide real-time, three-dimensional (3D) positioning and orientation of instruments relative to the patient s anatomy on a video display during surgery without requiring the use of an endoscope. Image-guided surgical navigation systems work in a similar way to global positions systems (GPS) applied to the human body. They provide medical images that show the location of the instruments in real time during the procedure, and one or more imaging modalities, such as computed tomography (CT) and/or magnetic resonance imaging (MRI), may be used in the procedure. Dedicated image-guided stereotactic systems intended for particular procedures such as neurosurgery, cardiac mapping and ablation, mammographic biopsy, and cranial, spinal, orthopedic, and laryngological surgery procedures are available. Image-guided systems intended to facilitate radio surgical procedures from the exterior of the body are also available.
The following Contract Line Items (CLINs) are being considered: Contract Line Item# Brand Part Number Description
0001 Medtronic 9735665 STEALTHSTATION S8 MAIN CART W/MONITOR
0002 Medtronic 9735670 STEALTHSTATION S8 CAMERA CART
0003 Medtronic 9735943 POWER PACK 9735943 STEALTH S8 ENG ONLY
0004 Medtronic M072707M014 STEALTHSTATION S7 to S8 System Trade In
0005 Medtronic M072707M015 STEALTHSTATION S8 System Do the SCs apply to this CLIN? - New
0006 Medtronic 9735740 STEALTHSTATION SPINE SOFTWARE
0007 Medtronic 9736428 REF SET 9736428 SPINE REFERENCING
0008 Medtronic 9735502 UPGRADE SET 9735502 PERC PIN
0009 Medtronic 9735501 Revision Referencing Tray
0010 Medtronic 9735522 Revision Referencing Tray Upgrade
0011 Medtronic NAV2024K DRIVER NAV2024 SOLERA 4.75 STANDARD MAS
0012 Medtronic NAV2025K DRIVER NAV2025 SOLERA 4.75 REDUCT MAS
0013 Medtronic 9735465 CD HORIZON® SOLERA® Awl-Tip Taps
0014 Medtronic 9735469 CD HORIZON SOLERA Taps
0015 Medtronic 9734492 SOLERA DEFORMITY TAPS UPGRADE
0016 Medtronic 9735283 SOLERA 5.5/6.0 DRIVERS
0017 Medtronic 9735285 SOLERA ILIAC TAPS
0018 Medtronic 9734838 TAP KIT 9734838 SOLERA 8.5 CANNULATED
0019 Medtronic 9734494 INST SET 9734494 TACTILE PROBES
0020 Medtronic 9735173 INST KIT 9735173 2.25MM PED PROBE
0021 Medtronic 9734836 INSERTER, CAPSTONE & CLYDESDALE SET
0022 Medtronic 9734833 NAVLOCK NAVIGATION INSTRUMENT SET
0023 Medtronic 9734834 CAPSTONE TRIALS SET (TLIF/PLIF)
0024 Medtronic 9734507 STEALTHSTATION® UNIVERSAL DRILL GUIDE
0025 Medtronic 9734835 CLYDESDALE TRIALS SET (DLIF)
0026 Medtronic 9734435 TACTILE AWL
0027 Medtronic 9735032 POWEREASE ADAPTER
0028 Medtronic 9735737 STEALTHSTATION CRANIAL SOFTWARE
0029 Medtronic 9735743 STEALTHSTATION 3D SOFTWARE
0030 Medtronic 9735745 STEALTHSTATION MERGE SOFTWARE
0031 Medtronic 9735739 STEALTHSTATION STEREOTAXY SOFTWARE
0032 Medtronic 9735738 STEALTHSTATION DBS SOFTWARE
0033 Medtronic 9735921 STEALTHSTATION DBS + STEREOTAXY SOFTWARE
0034 Medtronic 9735747 SCHALTENBRAND WHAREN ATLAS
0035 Medtronic 9736423 SW KIT 9736423 S8 2.0 TRACTOG
0036 Medtronic 9733935 CRANIAL INSTRUMENT SET - PASSIVE
0037 Medtronic 9730092 INST HNDL 9730092 PASS CATHETER INTROD
0038 Medtronic 9731965 TOUCH-N-GO KIT 9731965
0039 Medtronic 9733157 PROBE, 9733157, NAVIGUS
0040 Medtronic 9730269 MICROSCOPE PROBE
0041 Medtronic 9733936 VERTEK PASSIVE BIOPSY KIT
0042 Medtronic 961-337 INST REF FRAME 961-337 SM PASSIVE CR
0043 Medtronic 960-556 PASSIVE PLANAR BLUNT PROBE
0044 Medtronic 961-574 INSTRUMENT SET - SURETRAK II PASSIVE
0045 Medtronic 9734252 ARM 9734252 VERTEK II
0046 Medtronic 9735955 STEALTHSTATION EM KIT S8 CRANIAL ACCESSORIES
0047 Medtronic 9736149 ZEISS KINEVO INTERFACE KIT
0048 Medtronic 9736150 S8 DIGITAL HUD UPGRADE KIT
0049 Medtronic KINEVOS8 UPGRADE KINEVO KIT W/ S8 UPGRADE HARDWARE
0050 Medtronic 9736023 INTF KIT 9736023 ZEISS PENTERO HUD S8
0051 Medtronic 9736042 SCOPE KIT 9736042 S8 ZEISS UPG
0052 Medtronic 9736027 INTF KIT 9736027 LEICA HUD S8
0053 Medtronic 9736028 INTF KIT 9736028 LEICA PTR ONLY S8
0054 Medtronic 9735959 STEALTHSTATION EM KIT S8 FLAT EMITTER
0055 Medtronic 9735736 STEALTHSTATION ENT SOFTWARE
0056 Medtronic 9735742 SFW 9735742 STEALTH 3D ENT
0057 Medtronic 9733452XOM ENT NAVIGATION INSTRUMENT SET
0058 Medtronic 9736325 Monitor Cover 9736325 Stealth S8 SVC
0059 Medtronic 9736326 Camera Cover 9736326 Stealth S8 SVC
0060 Medtronic AUTOGUIDE_SYSTEM Stealth Autoguide System
0061 Medtronic 9736464 Stealth Autoguide Instrument Set
0062 Medtronic AUTOGUIDE_REG_KIT Stealth Autoguide Non-sterile Registration Kit
0063 Medtronic 9736189 Stealth Autoguide Visualase Instrument Set
0064 Medtronic 9736377 Stealth Autoguide STERILIZATION TRAY 9736377 AUTOGUIDE II
0065 Medtronic 9736382 Stealth Autoguide STERILE TRAY 9736382 AUTOGUIDE AND MR8
0066 Medtronic BI70002000 O-ARM O2 BASE
0067 Medtronic BI75000027 CONFIG BI75000027 O2 SYSTEM NAVIGATION INTERFACE
0068 Medtronic BI75000034 CONFIG BI75000034 O2 MULTIPLE FIELD OF VIEW
0069 Medtronic BI75000030 CONFIG BI75000030 O2 ADVANCED VIEWING
0070 Medtronic BI75000031 CONFIG BI75000031 O2 ISO-WAG ROTATION
0071 Medtronic BI75000032 CONFIG BI75000032 O2 COLLIMATED AXIAL 3D
0072 Medtronic BI75000029 CONFIG BI75000029 O2 HIGH DEFINITION 3D HD3D
0073 Medtronic BI75000045 O-ARM O2 2D LONG FILM - NEW SYSTEM
0074 Medtronic BI71000875 O-ARM O2 2D LONG FILM UPGRADE - EXISTING SYSTEM
0075 Medtronic BI75000046 O-arm O2 Medtronic Implant Resolution (MIR)
0076 Medtronic BI75000047 O-arm O2 Spine Smart Dose (SSD)
0077 Medtronic BI75000048 O-arm O2 3D Long Scan (3DLS)
0078 Medtronic BI75000050 O-arm O2 4.3.0, MIR, SSD and 3DLS - Active Service Agreement Customer
0079 Medtronic BI75000049 O-arm O2 4.3.0, MIR, SSD and 3DLS, and Computer for Non -Service Agreement Customer
0080 Medtronic BI75000051 O-arm O2 4.3.0, MIR, SSD and 3DLS, without computer for Non -Service Agreement Customer
Offerors must propose a complete solution including associated accessories, as required for the system s full functionality. The following Salient Characteristics (SCs) are being considered: SC # SALIENT CHARACTERISTICS METHOD OF EVALUATION SC 1 Must have a minimum of 27 high resolution touchscreen monitor Literature Review SC 2 Must have Real-time navigation of images with the ability to fuse 3D preoperative images for advanced planning Literature Review SC 3 Must be capable of interfacing with all of the following intraoperative imaging systems: MRI, CT, and 3D Ultrasound. Literature Review SC 4 Must have the ability to integrate with external devices for streamlined visualization workflows. Literature Review SC 5 Must be able to perform navigation for cranial neurosurgery and spine applications. Literature Review
SC 6 Must have optical and EM tracking capabilities Literature Review SC 8 Must be FDA 510(k) Approved Literature Review SC 9 Must provide a minimum one-year Manufacturer Warranty Literature Review SC 10 Must be interoperable with the VA Electronic Health Record System Literature Review
For each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics (SC) specified above. The Government's intent is to include all ancillary items to ensure the equipment can function as designed by the OEM and as required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number. In addition to the above CLINs and salient characteristics, the Government contemplates utilizing the below evaluation subfactors: Evaluation Subfactors 1. Safety Safety features and functions of the offered equipment will be evaluated. Areas may include but are not limited to the following: System security Maintenance reminders Emergency alarms
2. Design Design features and functions of the equipment offered will be evaluated. Areas may include but are not limited to the following: Touchscreen user interface and ease of use Image display quality and resolution Data storage and RAM memory Patient data management External device and instrument compatibility System footprint and weight Power and environmental requirements Optical and EM tracking capabilities Optical tracking volume Different types of Intraoperative imaging systems capable of interfacing with Ergonomics
3. Diagnostic Tools and Imaging Techniques Diagnostic tools and imaging techniques of the offered equipment will be evaluated. Areas may include but are not limited to the following: Patient registration Surgical navigation Tool tracking Image merging Procedure specific software applications Pre and intraoperative planning
4. Quality/Construction Aspects of the construction and quality of material of the equipment will be evaluated and may include but not limited to the following: Life span Warranty terms and conditions Maintenance requirements Service plans terms and conditions Training options
Responses to this Sources Sought Notice shall include the following:
Full name and address of company. SAM Unique Entity Identifier (UEI). Business Size. Manufacturer or Distributor: If distributor, provide full name, business size and address of manufacturer. If distributor, provide evidence that your firm is currently an authorized distributor for the manufacturer of the products proposed, e.g. an authorized distributor letter with current date certified by the OEM. Country of Origin designation for all products proposed. Ability to provide uninterrupted supply of products on a national scale. Technical Literature that clearly shows product(s) meets the identified salient characteristics and page numbers where each salient characteristic is met. Does vendor offer an annual service plan, Yes or No? If Yes: What does the plan cover? Does plan cover software updates only? Does the plan cover parts repair or replacement only? Does the plan cover both software and parts? Vendor is requested to provide documentation that shows information on their service plan. Is the service provided by the OEM or a subcontractor? Any additional product solution or configuration that would be beneficial to the functionality of the product line identified. Item pricing information of products, inclusive of flat rate shipping. Include any quantity discounts, noting at what level of quantity ordered should the Government expect tiered price reductions, if any. NOTE: In order for the Contracting Officer to determine whether a set-aside can be pursued, it is essential to provide pricing information. Without this information, the Contracting Officer will be unable to assess whether there is a reasonable expectation of receiving fair and reasonable pricing from socio-economic concerns. Does your firm have any subcontracting opportunities for this equipment? Identify any federal contracts vehicles held by your firm that provides this equipment. Are there any further standards or criteria, to include salient characteristics and subfactors, VA should consider in a procurement action for this equipment? Are the Government s specifications unduly restrictive? Any additional information the Government should know prior to issuing a solicitation.

More opportunities from Department Of Veterans Affairs → Sac Frederick (36C10X)

Same awarding agency

NAICS: 339112
New
Federal
NX EQ SURGICAL TISSUE MANAGEMENT SYSTEM
Solicitation # 36C10X26R0027
The Department of Veterans Affairs is seeking proposals for a nationwide firm-fixed-price requirements contract for the procurement of the Olympus ESG-410 Surgical Tissue Management System or an equivalent. The scope of work includes the primary system, accessories, consumables, installation, setup, training, proctoring services, and annual warranty and maintenance. The contract structure consists of a 12-month base period with four 12-month option periods. Award will be based on best value, with non-price factors—specifically technical capabilities, past performance, and veterans preference—weighted significantly more than price. To be eligible, offerors must achieve at least an acceptable technical rating, meet all salient characteristics, and provide a certified OEM letter. Offerors must submit proposals in five separate volumes, including detailed pricing in a cost schedule that incorporates a 3% Service Level Agreement fee. Key requirements include a certification that the medical equipment has no outstanding recalls or known safety issues and complies with all relevant safety and performance standards. Delivery is FOB Destination, and the government requires electronic invoicing through the Tungsten portal. Proposals must be submitted by the amended deadline of October 19, 2026, and must include a current SAM registration and a Buy American Certificate.
Surgical and Medical Instrument Manufacturing

POSTED

2 days ago

DEADLINE

in about 9 hours
View Details
NAICS: 561210
New
Federal
CRRC Facility Maintenance Services
Solicitation # 36C10X26Q0091
The Department of Veterans Affairs Strategic Acquisition Center Frederick is soliciting quotes for comprehensive facility maintenance support services for the Capital Region Readiness Center (CRRC) and associated sites in Martinsburg and Shepherdstown, West Virginia. The CRRC is a mission-critical, 24/7/365 operation encompassing approximately 66,300 gross square feet, including a 9,300 square foot raised-floor data processing environment. The contractor is required to provide all labor, supervision, equipment, and materials necessary to monitor, maintain, and repair critical infrastructure, including SCADA systems, chillers, emergency generators, UPS systems, fuel storage plants, and clean agent fire suppression, as well as general facility maintenance such as perimeter fencing and parking lot upkeep. All systems must be maintained according to manufacturer recommendations and industry best practices to ensure high operational availability and continuity of operations. This is a Firm Fixed Price contract set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 561210. The period of performance consists of a 12-month base period starting December 13, 2026, with four subsequent one-year option periods. The total ceiling value across the base and all option periods is approximately $679,173. Award will be based on a best-value trade-off, where technical capability and past performance are combined and weighted as significantly more important than price. Personnel assigned to the contract must possess at least three years of experience supporting industrial, mission-critical facilities. Quotes must be submitted in three separate volumes covering technical capability, past performance, and price, with a final response deadline of October 23, 2026.
Facilities Support Services

POSTED

5 days ago

DEADLINE

in 2 days
View Details
NAICS: 334510
New
Federal
6515--NX EQ Image Guided Surgical Navigation System (VA-26-00083972)
Solicitation # 36C10X27R0004_1
The Department of Veterans Affairs is soliciting proposals for a nationwide, firm-fixed-price requirements contract for the procurement of Medtronic Stealthstation S8 Image-Guided Surgical Navigation Systems or an equal alternative. This acquisition is specifically set aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 334510. The contract includes a base period of 12 months with four subsequent 12-month option years. All provided equipment must be new original equipment manufacturer (OEM) products, as refurbished or gray market items are prohibited, and all items must be covered by the manufacturer's warranty. Delivery is established as FOB Destination to various VHA locations, with a requirement for the contractor to provide order confirmation within four working days of receipt. Proposals will be evaluated based on best value, with technical factors and past performance combined being significantly more important than price. Technical evaluations require strict adherence to salient characteristics, while past performance is assessed based on relevant and recent contracts from the last three years. Offerors must submit their proposals in four distinct volumes: Technical, Past Performance, Price, and a volume for Offer, Amendments, Certifications, and Representations. Key compliance requirements include a 3% SLA fee embedded in the unit pricing, certification that equipment is free of outstanding recalls or safety issues, and adherence to ADA and HIPAA federal requirements. Payments are processed monthly in arrears via electronic funds transfer.
Electromedical and Electrotherapeutic Apparatus Manufacturing

POSTED

6 days ago

DEADLINE

in 15 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS