Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on May 22, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6515--Sources Sought: Colorectal Analyzer for the Northport VA Medical Center. In support of the Fecal Immunochemical Testing Program.

Awarded
36C24226Q0638Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334516
New
SLED
BCL27*382830-SoleSource-Geenius Reader, System-STD Testing
Solicitation # SRC0000037291
Solicitation SRC0000037291 is a sole source procurement issued by the Alabama Clinical Laboratory Services for the acquisition of a Bio-Rad Geenius Reader System and associated components for STD testing. This second round of solicitation follows a lack of bids in the first round. The required equipment includes the Geenius Reader System, a dedicated computer with accessories, a printer with USB cable, a barcode scanner, and a Windows 10 literature binder. Additionally, the procurement covers Geenius HIV 1/2 Supplemental Assay kits and corresponding positive and negative controls. The Geenius System is the only FDA-approved multiplex offering for the detection and differentiation of HIV-1 and HIV-2 antibodies in serum, plasma, or whole blood samples. Administered under the State of Alabama Quick Quote standard terms, the resulting contract may be renewed annually for up to five years or until a total cost of 25,000 dollars is reached. The procurement process requires electronic submission via Alabama Buys and mandates that suppliers certify compliance with Alabama tax laws, non-collusion, and immigration regulations. The State reserves the right to request professional licenses, insurance certificates, and manufacturer reseller authorizations. Legal venue for any disputes is established in Montgomery, Alabama, with the Board of Adjustment of the State of Alabama serving as the sole remedy for money claims.
Clinical Laboratory Services

POSTED

about 5 hours ago

DEADLINE

in 5 days
NAICS: 334516
New
SLED
SP Labs Automated Biological Oxygen Demand Analyzer
Solicitation # 27-532EPA-LAB53-B-54370
The Illinois Environmental Protection Agency Laboratory is soliciting a small purchase contract for an automated Biological Oxygen Demand (BOD) analyzer to perform BOD and Carbonaceous Biochemical Oxygen Demand (CBOD) analysis in compliance with Standard Method 5210B. The required system must be fully automated, including sample preparation, pH adjustment, dissolved oxygen reading, and the addition of dilution water, chemicals, seeds, or inhibitors. Technical specifications require a minimum capacity of 54 sample bottles of 300 mL each and the ability to pull rinse water from a pressurized line or container. The analyzer must be delivered and fully functional at the Springfield, Illinois laboratory within 60 days of contract execution, with on-site training for at least two analysts provided within four weeks of installation. To be considered responsive, bidders must provide pricing for both the analyzer and a mandatory three-year service contract that includes repair parts, labor, and one annual preventive maintenance visit. The equipment must also include a one-year warranty. The awarded vendor is required to maintain significant insurance coverage, including 1 million dollars per occurrence for general commercial and auto liability, and 2 million dollars in annual aggregate general liability. Payment will be processed upon completion in accordance with the State Prompt Payment Act, and the contract is subject to the availability of funds, which may include federal funding. Submission requirements include financial disclosures, standard Illinois certifications, and pricing via the BidBuy portal.
FISCPROC532 - Fiscal / Procurement

POSTED

about 13 hours ago

DEADLINE

in 6 days
NAICS: 334516
New
Federal
6550--Sources Sought: Tuberculosis Testing Reagents and Consumables for the Buffalo VA Medical Center. In support of the Tuberculosis (TB) Testing Program
Solicitation # 36C24227Q0095
The Department of Veterans Affairs, VISN 02 Network Contracting Office, has issued a Sources Sought Notice under solicitation number 36C24227Q0095 to identify qualified sources for tuberculosis testing reagents and consumables for the Buffalo VA Medical Center. This request is for information and planning purposes only and does not constitute a formal solicitation. The government is seeking a domestic source capable of providing FDA-cleared reagents, test kits, controls, and processing materials that are compatible with the T-SPOT TB testing platform and methodology. All items must be delivered in original manufacturer packaging with sufficient shelf life and meet all manufacturer specifications for accuracy and performance within an accredited clinical laboratory environment. Interested respondents must submit their capabilities via email to the contracting officer by November 12, 2026. Submissions must include the company's Sam.gov Unique Entity ID, business size status relative to NAICS code 334516, and details regarding whether they are a manufacturer or distributor. The government is specifically looking for information on business representations such as SDVOSB, VOSB, Hubzone, and WOSB status, as well as any existing federal contracts through GSA, NAC, or NASA SEWP. While general pricing is encouraged for market research, it will not be used for award evaluation. Responses must demonstrate clear evidence that any equivalent products meet all salient characteristics and specify if the items are manufactured within the United States.
242-NETWORK Contract Office 02 (36C242)

POSTED

about 13 hours ago

DEADLINE

in 14 days

AI Contract Overview

Show more

The Department of Veterans Affairs, through the VISN 02 Network Contracting Office, is seeking information from potential suppliers regarding a colorectal analyzer to support the mailed Fecal Immunochemical Testing Program at the Northport VA Medical Center, with the intent of gathering market data for future acquisition planning. This is a Sources Sought Notice issued solely for information and planning purposes under FAR 15.201(e) and does not constitute a solicitation, offer, or binding contract. Respondents are required to provide detailed information demonstrating their ability to supply an analyzer that meets specific technical and operational requirements, including FDA approval, domestic manufacturing in the United States, bi-directional interface capability with Vista and/or Data Innovation middleware, and compatibility with VA barcode standards such as Code 39, Code 128, and Codabar. The equipment must support random access and walk-away testing, enable reagent loading during operation, scan patient samples without manual entry, include a 120-volt UPS with a 2–3 hour backup, and ensure result integrity by eliminating sample carryover. Reagents must have a minimum six-month shelf life upon delivery, and the system must function reliably within a temperature range of 50 to 90 degrees Fahrenheit and humidity levels of 15 to 85 percent. The instrument must produce accurate, reproducible results using in vitro immunochemical methods to detect human hemoglobin, eliminating dietary restrictions and the need for multiple samples, and include a specimen transport system stable for at least 14 days at ambient temperature, compliant with USPS mailing requirements. The vendor must provide on-site installation and training for at least one staff member, a minimum one-year warranty, and annual preventive maintenance with extended repair services. Validation must comply with Clinical and Laboratory Standards Institute standards, and the system must store and retransmit up to 24 hours of maximum throughput data. Respondents must submit their company name, address, point of contact, Sam.gov Unique Entity ID, and detailed responses addressing the salient characteristics, including evidence that their solution is equivalent to or exceeds all specified requirements. They must also declare their business size classification under NAICS code 334516 with a 1,000-employee size standard, indicate whether they are a manufacturer, distributor, or equivalent provider, and disclose any subcontracting plans with percentage breakdowns. Socioeconomic status must be indicated, including potential designations as Service Disabled Veteran Owned Small Business, Veteran Owned Small Business, Hubzone

General Info

VA seeks domestic FDA-approved colorectal analyzers with advanced testing and interface capabilities.

Contract Value

$30,000

NAICS

334516 - Analytical Laboratory Instrument Manufacturing

Place of Performance

Northport VA Medical Center, Northport, NY, 11768, USA

Set-Aside

NONE

Award Issued Date

Documents

1

Sources Sought: Colorectal Analyzer for Northport VA Medical Center - 36C24226Q0638

DOCX, Low prioritysources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseAwarded
Posted

Sources Sought

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)
Contacts1 person available
OfficeALBANY, NY, 12208, USA
Office AddressALBANY, NY, 12208, USA
Contacts
Rondon JonatanContracting Officer

Full Description

Show more
THIS REQUEST IS FOR SOURCES SOUGHT AND IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This Sources Sought Notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this Sources Sought Notice is marked as proprietary and will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this Sources Sought Notice. SOURCES SOUGHT DESCRIPTION This is NOT a solicitation announcement. This is a Sources Sought Notice only. The purpose of this Sources Sought Notice is to gain knowledge of potential qualified sources and their size classification relative to NAICS code 334516 analytical laboratory instrument manufacturing (size standard of 1,000 employees). Responses to this Sources Sought Notice will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice, a solicitation announcement may be published. Responses to this sources sought synopsis are not considered adequate responses for a solicitation announcement. The Department of Veterans Affairs (VA), VISN 02 Network Contracting Office, is seeking sources that can provide a colorectal analyzer to support the mailed Fecal Immunochemical Testing Program for VISN 2 that at a minimum meets the following salient characteristics listed below. The VA is seeking a domestic source (manufactured in the United States) equivalent to the following salient characteristics: Technical parameters Equipment functionality is accurate, timely and reliable in performing the test and transferring the information across the interface if it is interfaced. The instrument and the test are FDA-approved. Preferably capable of Bi-directional Interface with Vista and/or Data Innovation (middleware). Any bi-directional interface to/from Vista must be able to handle necessary drivers to send/receive orders. Immediate start-up capabilities. Calibration frequency. Characteristics of analyzers: onboard stability of reagents and QC reagents. Vendor provides on-site technical assistance for the initial instrument set-up, including but not limited to data collection and analysis (e.g. data for methods and instruments comparisons). Detailed instrument specifications. Scan in patient samples. No manual entry. Ability to change or load reagents while instrument is operating. Ease of use, random access and walk away testing are all required. Reagents must have a minimum shelf life of six (6) months at the time of delivery. Equipment to be delivered/assembled upon receipt to the medical center. Training of staff, at least one person, to be performed on site. Statement of warranty of equipment, minimum one year. Statement of service included: preventive maintenance at least once per year; extended service and repair. capable of producing accurate and reproducible results on fecal specimens by established in vitro immunochemical diagnostic methods. capable of specifically detecting human hemoglobin, thereby removing the need for dietary restrictions and the collection and testing of more than one sample. a specimen transport system that is stable for a minimum of 14 days at ambient temperature for those specimens collected in the home setting mailing system for specimen transport that meets the US Postal Service mailing requirements, including but not limited to specimen collection and labeling instructions, specimen transport tube/vial/card, and mailing envelope. analyzers capable of providing printouts for all patient results, calibrators, and controls. a design that supports the result integrity removing the possibility of sample carryover. equipment that perform satisfactorily at any laboratory relative humidity between 15 and 85 percent and any laboratory temperature between 50- and 90-degrees Fahrenheit (10 to 30 degrees Celsius). Analyzer equipment which includes 120-volt UPS that has a 2 3-hour back-up capability. Compatible with multiple barcode formats including but not limited to: Code 39, Code 128, and Codabar or current VA standardized barcode that may be enabled concurrently. System with ability to store and retransmit records (24 hours of maximum instrument throughput) Sufficient accuracy studies and validation methods to meet current standards defined by Clinical and Laboratory Standards Institute (CLSI). The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications.
If you are interested and are capable of providing the sought out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: Please indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)? (2) Is your company considered small under the NAICS code identified under this RFI? (3) Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above? (4) If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available). (5) If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? (6) If you intend to sub contract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to sub contracted work and completion of job. (7) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract number. (8) If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract? (9) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. (10) Please submit your capabilities in regard to the salient characteristics being provided and any information pertaining to equal to items to establish capabilities for planning purposes? (11) Will the items you will be providing manufactured domestically in the United States or are they foreign manufactured items? (12) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A. (13) Please provide your Sam.gov Unique Entity ID number. *** Submissions addressing number (10) should show clear, compelling and convincing*** evidence that all equal to items" meet all the salient characteristics. Responses to this notice shall be submitted via email to contact@example.gov telephone responses shall not be accepted. Responses must be received no later than June 5th, 2026, at 1600 EST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.

More opportunities from Department Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)

Same awarding agency

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS