This Sources Sought opportunity from Department Of Veterans Affairs was posted on July 22, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
6515--West (660) RFID Cabinet for Surgery Service
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
The Department of Veterans Affairs, Veterans Health Administration, through Network Contracting Office 19, is conducting market research to identify qualified vendors capable of providing a Radio Frequency Identification (RFID) storage cabinet integrated with InVita UDTracker® software for the automated tracking of tissues, biologics, and implantable medical devices at the Salt Lake City VA Medical Center. The system must support ultra-low temperature storage between -20°C and -80°C, deliver real-time inventory visibility, maintain a complete electronic chain-of-custody, and automate expiration alerts and usage reporting while complying with AATB, FDA, and Joint Commission standards. The solution must include high-density cabinets with 100% RFID scanning coverage, secure electronic access controls, tamper-resistant enclosures, battery backup, remote monitoring, and seamless integration with hospital EMR/EHR and MMIS systems via secure APIs. The goal is to reduce implant retrieval time, minimize human error, prevent product loss and waste, and improve overall inventory efficiency in surgical and cath lab settings. Interested contractors must respond with a completed market research questionnaire including company details, UEI number, business size certifications, FSS/GSA contract status if applicable, proposed pricing model, and compliance with Buy American Act requirements. Responses must include information on delivery timelines, domestic content percentages, and subcontracting plans if applicable, particularly for small businesses subject to limitations on subcontracting and the nonmanufacturer rule. The NAICS code designated is 339112 for Surgical and Medical Instrument Manufacturing, and responders are encouraged to suggest alternative codes if their proposed solution better fits another classification. All submissions must be emailed by 5:00 p.m. MST on August 5, 2026, not exceed eight pages, and be clearly marked as proprietary if containing sensitive business information. This notice is strictly for market research and does not obligate the government to issue a solicitation or make an award.
General Info
Agency
NAICS
Place of Performance
Department of Veterans Affairs, Salt Lake City, CO, 84148Set-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
Sources Sought Notice Radio Frequency Identification (RFID) Cabinet Disclaimer: This Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
Information Requested from Industry:
In response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List. Responses to market research table questionnaire shall be submitted. If this information is not provided, then it will be assumed the entire requirement cannot be met.
Description of Requirement: The Department of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for a Radio Frequency Identification (RFID) storage cabinet integrated with Unique Device Identifier (UDI)-compliant tissue and implant tracking software to support patient safety, regulatory compliance, and efficient inventory management. This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied that the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided.
Requirement Item: (1) InVita UDTracker® RFID Cabinet consisting of Terso Solutions RFID cabinet hardware integrated with InVita's UDTracker® tissue and implant tracking software to support real-time, automated inventory management of tissues, biologics, and implantable medical devices at Salt Lake City VA Medical Center. Together, the hardware and software shall deliver complete inventory visibility, reduce implant retrieval time from storage to the operating room, improve reconciliation efficiency, minimize human error, and reduce product loss, expired waste, and stockouts. The system is intended for use in operating rooms, cardiac catheterization (Cath) laboratories, ambulatory surgery centers, or other locations where high-value medical inventory is stored.
Required Salient Characteristics:
Core Functionality RFID-enabled ultra-low temperature storage for tissues, implants, blood products, and biologics. Automated tracking of every item placed in or removed from the freezer. Real-time visibility of inventory levels with full chain-of-custody history. Automated expiration alerts and usage reporting
Technical Specifications Ultra-low temperature capability depending on model (typically -20°C to -80°C). Integrated high-frequency RFID antennas ensuring 100% scanning coverage. Secure electronic locking system with access control integration. High-density storage capacity ranging from ~57 to 192 items (varies by configuration).
Integration & Interoperability Seamless integration with InVita UDITracker Tissue & Implant Management system. Compatible with hospital EMR/EHR and MMIS systems using secure API connections. Supports automated documentation and regulatory compliance workflows
Compliance & Regulatory Features Supports AATB, FDA, and Joint Commission documentation and tracking requirements. Maintains complete electronic chain-of-custody for all stored products. Temperature monitoring compliant with healthcare cold-chain standards
Security & Audit Controls User-specific access tracking with electronic audit trails. Automatic logging of any attempt to access or modify stored items. Tamper-resistant enclosure with secure RFID-tag authentication
Environmental & Operational Features Energy-efficient cooling system designed for continuous operation. Battery backup for short-term power outages (model dependent). Remote monitoring capabilities including temperature alerts and door-open notifications
Performance & Reliability Validated read accuracy approaching 100% with RFID-tagged items. Reduces waste and loss through automated expiration and usage tracking. Demonstrated cost savings (e.g., Reston Hospital reported ~$200k annual waste reduction).
In response to this announcement, please provide the information requested below requested in this market research table questionnaire. If this information is not provided, then it will be assumed the entire requirement cannot be met: NAICS Code: Company Name: Address: UEI (Unique Entity ID) Number: Contact Name: Phone No.: Email: Business Size Information - Select all that applies: Small Business Emerging Small Business Small Disadvantaged Business Certified under Section 8(a) of the Small Business Act HUBZone Woman Owned Certified Service-Disabled Veteran Owned Small Veteran Owned Small Business Large Business FSS/GSA Contract Holder: Yes No FSS/GSA Contract Number:
Effective Date/ Expiration Date:
Proposed solution is listed and available on the above FSS/GSA Contract: Yes No Available pricing structure of proposed solution (select all that are applicable below, or remove to fit your requirement): Pricing Model Please Indicate Availability Below: (Yes / No / NA) All on FSS Open Market only Mix of FSS & Open Market Firm-Fixed Price
Market Rearch Questions: How long from execution of order/contract to delivery of product? Buy American Act RFO 52.225-1 and RFO 52.225-2 Buy American Certificate What percentage of the proposed product (including leases and rentals) is a: Domestic end product? _____________ (%) Foreign end product? _______________ (%) Country of Origin: Questions for Small Businesses ONLY: Limitations on Subcontracting RFO 52.219-14
What percentage of the work would be subcontracted to another company? ________ What is the business size of the subcontractor?______
Per RFO 52.219-14 the following conditions must be met:
Supplies (other than procurement from a nonmanufacturer of such supplies), it will not pay more than 50 percent of the amount paid by the Government for contract performance, excluding the cost of materials, to subcontractors that are not similarly situated entities. Any work that a similarly situated entity further subcontracts will count towards the prime contractor's 50 percent subcontract amount that cannot be exceeded. When a contract includes both supplies and services, the 50 percent limitation shall apply only to the supply portion of the contract;
If subcontracting, what added value do you offer (RFO 52.215-23): Nonmanufacturer Rule (RFO 52.219-33): Does your company manufacturer these proposed items? [Â ] yes [Â ] no Does your company exceed 500 employees? [Â ] yes [Â ] no If yes, list # of employees: _________ Does your company primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied? [Â ] yes [Â ] no Does your company take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? [Â ] yes [Â ] no Does your company supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406. [Â ] yes [Â ] no If yes, what is the manufacturer s name? ________________
Response Instructions: Do not provide more than 8 pages, including cover letter page. Submit your response via email to heather.chase2@va.gov. Submit your response NLT 5:00pm (MST) on Wednesday, August 5, 2026. Mark your response as Proprietary Information if the information is considered business sensitive. VA has identified the appropriate North American Industry Classification System (NAICS) Code as 339112 Surgical and Medical Instrument Manufacturing with a Small Business size of 1,000 Employees. Please identify and explain any NAICS codes your company believes would better represent the predominant work included in the attached Statement of Work / Salient Characteristics List.
(End of Sources Sought)
More opportunities from Department Of Veterans Affairs → Network Contract Office 19 (36C259)
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS
