Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

6530--Domestic Equivalent to Guldmann Ceiling Lifts White River Junction VA Medical Center

Active
36C24126Q0780Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This Sources Sought Notice is a market research effort by the Department of Veterans Affairs to identify industry capabilities for providing and installing patient safety lifts at the White River Junction VA Medical Center. This is not a solicitation for proposals, and no contract will be awarded from this synopsis. Interested firms must be registered in the System for Award Management and provide company details, performance capabilities, socio-economic status, and place of manufacture to be considered for future planning. The requirement includes the installation of 21 patient safety lift systems, which involves the removal of 18 existing systems and the provision of stamped engineering calculations. Technical specifications require compliance with ISO 10535:2021, featuring a mix of XY systems and linear tracks made from Aluminum 6063 T6. The project encompasses 17 lifts supporting 550 lbs and 4 lifts supporting 825 lbs, along with 21 medium hanger bars, 84 slings, and a specialized trainer module motor. Key features include Wi-Fi connectivity for monitoring, continuous in-rail charging, and impact-resistant, flame-retardant housing.

General Info

VA market research for installing 21 patient safety lifts at White River Junction.

Agency

Department Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)View Agency

NAICS

339113 - Surgical Appliance and Supplies ManufacturingView NAICS

Place of Performance

ME

Set-Aside

NONE

Documents

(1)

36C24126Q0780.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

What is UCF?

Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseSources Sought
Posted

Sources Sought

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)
Contacts1 person available
OfficeTOGUS, ME, 04330, USA
Organization / Agency
Department Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)
View Agency Profile
Office AddressTOGUS, ME, 04330, USA
Contacts
Kurt FritzContract Specialist

Full Description

Show more
THIS IS A SOURCES SOUGHT NOTICE ONLY: This announcement seeks information from the industry, which will be used for preliminary planning purposes for procurement. No proposals are being requested or accepted with this synopsis. THIS IS NOT A SOLICITATION FOR PROPOSALS AND NO CONTRACT SHALL BE AWARDED FROM THIS SYNOPSIS. THIS IS STRICTLY MARKET RESEARCH.
Patient safety lifts
The purpose of this synopsis is to gain knowledge of interest, capabilities, and qualifications of various members of industry, who have the capability to provide Patient safety lifts.
All interested firms must be registered in SAM (System for Award Management) to be eligible for the award of Government contracts. Interested parties responding to this Sources Sought request shall submit the following information at a minimum:
(1) Company name and address point of contact with phone number and SAM UEI. (2) Documentation relating to performance capability, current point of contact, and phone number). (3) Socio-economic status to identify the business class as a large business, SDVOSB, VOSB, small business, Woman Owned, etc. (4) Place of manufacture (5) Any other pertinent company documentation prior to submission of offers to a solicitation.
Any SD/VOSB firms responding to this Sources Sought Notice must also provide proof of registration in the SBA Vet Cert prior to submitting offers to a solicitation.
This market research is for informational and planning purposes. This is not a solicitation and does not obligate the Government to issue a solicitation. Please be advised that the government will not pay any costs for responses and information submitted. All submissions are acceptable via email to kurt.fritz@va.gov RESULTS INFORMATION: Respondents will not be notified of the results, and it is at the discretion of the Government to utilize results. Firms responding to this Sources Sought announcement, who fail to meet all requirements as stated above, and who fail to provide ALL the required information requested, will not be used to help the Government make the acquisition decision, which is the intent of this sources sought announcement.




Salient characteristics
(QTY 21) Patient Safety Lifts
All ceiling mounted hoists, rails, and components must comply with ISO 10535:2021
xy Systems Must be able to be flush mounted to a structural ceiling, integrated Into Suspended (Drop) Ceilings, or wall mounted. Cover 5m X 10m area with trainer (QTY 1) Cover 4m X 4m area (QTY 9) Cover 4m x 3m area (QTY 2) Cover 3m x 3m area (QTY 1) Linear Tracks Must be able to be flush mounted to a structural ceiling, integrated Into Suspended (Drop) Ceilings, or wall mounted. 3m Linear Track (QTY 3) Must be made from Aluminum 6063 T6 or better. Must have an anodized surface finish or better. Must support up to 550 lbs. or better
4m Linear Track (QTY 4) Must be made from Aluminum 6063 T6 or better. Must have an anodized surface finish or better. Must support up 825 lbs. or better 6m Linear Track (QTY 1) Must be made from Aluminum 6063 T6 or better. Must have an anodized surface finish or better. Must support up to 550 lbs. or better
Patient Lift Supports minimum 550 lbs. (QTY 17) Motor Speed: 60 millimeters every second or better. Horizontal Motor Option: Can include a motorized horizontal traverse along the ceiling rail, operated via hand control or IR remote. Digital System Integration: Supports Wi Fi connectivity for usage monitoring, service alerts, and data logging through a centralized digital platform. Safety Features: Includes mechanical and electrical emergency lowering, emergency stop, and overload protection. Manual Position Locks. Operating Noise: 50 to 60 dB(A). Battery System: Uses 24 V NiMH batteries with automatic activation, soft start/stop, and charge times of about 2 hours (for this capacity class). Main body dimensions: 580 mm × 345 mm × 156 mm. Impact resistant. Flame retardant housing. Continuous In-Rail Charging. LCD screen capable of displaying patient weight and lift usage information.
Patient Lift Supports minimum 825 lbs. (QTY 4) Motor Speed: 60 millimeters every second or better. Horizontal Motor Option: Can include a motorized horizontal traverse along the ceiling rail, operated via hand control or IR remote. Digital System Integration: Supports Wi Fi connectivity for usage monitoring, service alerts, and data logging through a centralized digital platform. Safety Features: Includes mechanical and electrical emergency lowering, emergency stop, and overload protection. Manual Position Locks. Operating Noise: 50 to 60 dB(A). Battery System: dual 24 V NiMH batteries with automatic activation, soft start/stop, and charge times of about 4 hours or better Main body dimensions: 580 mm × 345 mm × 156 mm. Impact resistant. Flame retardant housing. Continuous In-Rail Charging. LCD screen capable of displaying patient weight and lift usage information.
Medium Hanger Bar (QTY 21) Lifts up to 825 lbs. Four attachment points for a safe, stable, and comfortable lift. Works with ceiling and mobile lifts and fits standard slings. Strong, rust resistant metal covered with soft, easy to clean foam. Lightweight (4 lbs.) and easy to handle. Medium size (~24 wide) Trainer Module Motor (QTY 1) Reducing bodyweight, relieves up to 100 kg (220 lbs.), Built into the ceiling hoist added to system, controlled via the hand control interface. Safe exercise sessions: positioning lock and fall protection, enabling standing exercises, squats, steps, balance training, and sit-to-stand movements. 30-minute training limit: each session lasts up to 30 minutes per full battery charge, with clear indicators for weight relief and remaining time. After session, will automatically resume normal lift mode. Battery management: 1 hour of charge delivers about 10 minutes of training time. When training ends, it reverts to standard lifting and resumes charging. Installation (QTY 21) Install lift systems in 21 rooms. Labor and the hardware necessary to install the lift systems. Must support up to Level II that is identified in the Infection Control Risk Assessment (ICRA). Perform weight testing and certification of the installed lift systems. Removal of 18 existing lift systems. Design / Drafting (QTY 1) Stamped Engineering Calculations Slings (QTY 84) Support 450 lbs. or better Made from polypropylene material Disposable Limb Sling (QTY 1 per system) Disposable Basic High sling (QTY 1 per system) Disposable Twin Turner (QTY 1 per system) Disposable Repositioning Sling (QTY 1 per system) User Training (QTY 1)

Similar Contracts

Same NAICS industry code

NAICS: 339113
New
Federal
6515--Lecanto Community-Based Outpatient Clinic Patient Ceiling Lift Package
Solicitation # 36C24826Q1041
The Department of Veterans Affairs, under the Tampa Health Care System, is soliciting bids for solicitation number 36C24826Q1041 to provide and install ceiling-mounted patient lifts at the Lecanto Community-Based Outpatient Clinic in Lecanto, Florida. These lifts are required for safe patient movement to and from treatment tables within the Primary Care and Radiology departments as part of a clinic expansion and replacement project. The government is seeking a brand name or equal equipment solution, specifically referencing the Goldmann GH3 system, that meets all physical, functional, and performance characteristics outlined in the statement of need. The scope of work includes the delivery of the lift system, professional installation, and the provision of stamped drawings. This opportunity is designated as a Service-Disabled Veteran-Owned Small Business set-aside under NAICS code 339113. The base performance period for the project is scheduled from September 1, 2026, to November 30, 2026. Interested contractors must submit their responses by September 3, 2026, at 12:00 PM, and all inquiries must be directed to the contracting officer, Katrina Tavares, by September 1, 2026. Vendors are also required to provide necessary payment and registration data via VA Form 10091 to ensure compliance with federal electronic payment regulations.
248-NETWORK Contract Office 8 (36C248)

POSTED

about 16 hours ago

DEADLINE

in 7 days
View Details
NAICS: 339113
New
Federal
6515--Mobile Lead Radiation Shielding Barriers
Solicitation # 36C25526Q0630
The Department of Veterans Affairs Network Contracting Office 15 is soliciting quotes for a firm fixed price contract to provide six mobile lead radiation shielding barriers for the Eastern Kansas Healthcare System. These barriers will support pain management clinics at the Dwight D Eisenhower VA Medical Center in Leavenworth and the Colmery-O'Neil VAMC in Topeka to protect clinical staff during fluoroscopy-guided procedures. The requirement consists of two SoloShield Mobile Radiation Barriers with 0.5 mm lead equivalent transparent windows and four mobile lead barriers with 2.0 mm lead equivalent shatter-resistant glass windows. All equipment must be new original equipment manufacturer items, latex-free, and include the manufacturer's standard warranty and user manuals. This procurement is a total small business set-aside under NAICS code 339113. Award will be made to the responsible offeror determined to be most advantageous to the government, considering price and past performance. Offerors must provide an authorized distributor letter from the OEM and comply with Buy American and security prohibition requirements. Shipping is FOB destination, and installation will be handled by VA Biomedical Engineering staff. Invoices are to be submitted electronically upon acceptance of the items. The response deadline is September 1, 2026, at 4:00 PM.
255-NETWORK Contract Office 15 (36C255)

POSTED

about 16 hours ago

DEADLINE

in 5 days
View Details

More opportunities from Department Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)

Same awarding agency

NAICS: 236220
New
Federal
402-23-794 Modernize Campus Corridors
Solicitation # 36C24126R0120
This contract is a Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside solicitation for the Modernize Campus Corridors project at the Togus VA Medical Center in Augusta, Maine, designated exclusively for the VISN1 Construction MATOC IDIQ Pool. The project entails a 15,600-square-foot interior renovation of the Main Street Corridor linking Buildings B209 and B221, involving complete demolition, site preparation, and construction to modernize flooring, roofing, interior finishes, and HVAC systems within an active medical facility. All work must be executed without disrupting medical operations, requiring detailed phasing plans, strict life safety protocols, environmental protections, and coordinated temporary utility solutions. The contractor is responsible for safeguarding existing infrastructure, managing secure document handling, complying with infection control measures, and fully restoring all affected areas to meet VA and federal regulatory standards. The solicitation, numbered 36C24126R0120, was posted on July 31, 2026, with a response deadline of August 31, 2026, and falls under NAICS code 236220 for building construction. The award will be managed by the Department of Veterans Affairs, specifically the 241-NETWORK Contract Office 01 based in Togus, Maine, with performance occurring at the Augusta location. Primary point of contact is Alexandru Sava, and secondary contact is Diane C. Davis, both reachable via VA email. The project must adhere to all federal requirements and VA-specific construction protocols to ensure a safe, fully compliant, and operationally functional corridor system.
Commercial and Institutional Building Construction

POSTED

about 16 hours ago

DEADLINE

in 12 days
View Details
NAICS: 561710
New
Federal
Preventive Pest Management and Emergency Pest Control Services for the Bedford VA Medical Facility
Solicitation # 36C24126Q0734
The Department of Veterans Affairs is soliciting quotations for preventive and emergency pest management services at the Edith Nourse Rogers Memorial Veterans Hospital in Bedford, Massachusetts. This is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 561710. The contract utilizes an Integrated Pest Management (IPM) approach to maintain a rodent and pest-free environment across all campus buildings and perimeters. The scope of work includes scheduled preventive treatments, exclusion services to block entry points, and emergency on-call services for pests and wildlife. The performance period consists of a base year from October 1, 2026, to September 30, 2027, with four subsequent one-year option periods. Key operational requirements include a two-hour on-site response time for emergency calls and a four-hour response for non-emergency calls. All technicians must hold a current Massachusetts State Applicator license and comply with VHA Directive 1850.02(1) and federal, state, and local regulations. Award decisions will be based on a comparative evaluation of technical capability, past performance, and total evaluated price. Offerors must submit a written IPM plan, a signed certificate of compliance regarding subcontracting limitations, and a past performance worksheet. Responses are due by August 28, 2026, at 12:00 PM via email to the designated point of contact.
Exterminating and Pest Control Services

POSTED

about 16 hours ago

DEADLINE

in 8 days
View Details
NAICS: 621330
New
Federal
AN41--BPA for CPT trainers RFQ Q&A Document Posted with Extension
Solicitation # 36C24126Q0687
The Department of Veterans Affairs Network Contracting Officer 01 is seeking quotations for a Blanket Purchase Agreement to obtain licensed Cognitive Processing Therapy (CPT) trainers. This procurement is a total small business set-aside under NAICS code 621330 and PSC AN41. The selected national experts, who must possess at least 10 years of experience in conducting CPT reviews for clinical trials, will provide guidance on therapy modifications, conduct weekly case reviews for clinicians, and perform fidelity reviews to ensure adherence to research protocols. The BPA has a total period of performance of five years, with individual trainer assignments lasting one year each. The place of performance is the Boston VA Medical Center in Massachusetts. Evaluation of quotes will be based on price, technical capabilities, and past performance. Technical requirements include proof of clinical and behavioral psychology licensing and a detailed quality control plan. Offerors must also provide three references for equivalent work completed within the last ten years. To be eligible for award, prospective firms must be registered in SAM.gov, verified by the Small Business Administration if claiming small business status under the Veteran's First Contracting Program, and vendorized via VA Form 10091. The submission deadline has been extended to September 9, 2026, at 9:30 AM EST.
Offices of Mental Health Practitioners (except Physicians)

POSTED

about 16 hours ago

DEADLINE

in 12 days
View Details
NAICS: 238220
New
Federal
N041--Building 4 Chiller Replacement at VAMC Central Western MA
Solicitation # 36C24126Q0713
The contract titled N041--VAMC Central Western MA Building 4 Chiller Replacement solicits bids for the replacement of a chiller system at the Veterans Affairs Medical Center in Leeds, Massachusetts, under solicitation number 36C24126Q0713. This is a combined synopsis and solicitation issued by the Department of Veterans Affairs through its 241-NETWORK Contract Office 01, with the prime point of contact being Contract Specialist Juliette Buchanan. The opportunity is specifically set aside for Service-Disabled Veteran-Owned Small Businesses as defined under FAR 19.14, ensuring priority consideration for eligible small businesses owned and controlled by veterans with service-connected disabilities. The North American Industry Classification System code 238220 indicates the work falls under plumbing, heating, and air-conditioning contracting, requiring qualified contractors with expertise in HVAC system replacement and integration. The response deadline for proposals is August 21, 2026, at 8:00 PM Eastern Time, following a posting date of August 4, 2026. Performance of the work will occur at the specified location in Leeds, Massachusetts, with all contractual obligations tied to this site. The contracting office is headquartered in Togus, Maine, and interested parties must submit responses in accordance with the instructions provided in the combined synopsis/solicitation document linked via the SAM.gov portal. Compliance with all technical, administrative, and small business verification requirements under the SDVOSB set-aside is mandatory for eligibility and award consideration.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

about 16 hours ago

DEADLINE

in 8 days
View Details