6530--Domestic Equivalent to Guldmann Ceiling Lifts White River Junction VA Medical Center

Closed
36C24126Q0780Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The Department of Veterans Affairs is conducting market research through a Sources Sought Notice to identify industry capabilities for providing domestic equivalent patient safety lifts for the White River Junction VA Medical Center. This is not a formal solicitation, and no contracts will be awarded from this synopsis. The government is seeking information on firms capable of providing 21 patient safety lift systems, including a mix of lift supports with capacities of 550 lbs and 825 lbs, aluminum linear tracks of various lengths, medium hanger bars, and a specialized trainer module motor. The scope also includes the removal of 18 existing systems, installation of the new systems in 21 rooms, stamped engineering calculations, 84 specialized slings, and user training. Technical requirements specify that all ceiling-mounted components must comply with ISO 10535:2021 and that installation must adhere to Level II Infection Control Risk Assessment standards. The contractor will be responsible for weight testing and certification of all installed systems. Interested respondents must be registered in the System for Award Management and provide their company details, performance capabilities, place of manufacture, and socio-economic status. Specifically, SDVOSB and VOSB firms must provide proof of registration in the SBA Vet Cert. All responses must be submitted via email to the designated contract specialist by September 10, 2026.

General Info

VA market research for installing 21 patient safety lifts at White River Junction.

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

ME

Set-Aside

NONE

Documents

1

36C24126Q0780 Sources Sought Notice - Patient Safety Lifts

DOCX, Low prioritysources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)
Contacts1 person available
OfficeTOGUS, ME, 04330, USA
Office AddressTOGUS, ME, 04330, USA
Contacts
Kurt FritzContract Specialist

Full Description

Show more
THIS IS A SOURCES SOUGHT NOTICE ONLY: This announcement seeks information from the industry, which will be used for preliminary planning purposes for procurement. No proposals are being requested or accepted with this synopsis. THIS IS NOT A SOLICITATION FOR PROPOSALS AND NO CONTRACT SHALL BE AWARDED FROM THIS SYNOPSIS. THIS IS STRICTLY MARKET RESEARCH.
Patient safety lifts
The purpose of this synopsis is to gain knowledge of interest, capabilities, and qualifications of various members of industry, who have the capability to provide Patient safety lifts.
All interested firms must be registered in SAM (System for Award Management) to be eligible for the award of Government contracts. Interested parties responding to this Sources Sought request shall submit the following information at a minimum:
(1) Company name and address point of contact with phone number and SAM UEI. (2) Documentation relating to performance capability, current point of contact, and phone number). (3) Socio-economic status to identify the business class as a large business, SDVOSB, VOSB, small business, Woman Owned, etc. (4) Place of manufacture (5) Any other pertinent company documentation prior to submission of offers to a solicitation.
Any SD/VOSB firms responding to this Sources Sought Notice must also provide proof of registration in the SBA Vet Cert prior to submitting offers to a solicitation.
This market research is for informational and planning purposes. This is not a solicitation and does not obligate the Government to issue a solicitation. Please be advised that the government will not pay any costs for responses and information submitted. All submissions are acceptable via email to kurt.fritz@va.gov RESULTS INFORMATION: Respondents will not be notified of the results, and it is at the discretion of the Government to utilize results. Firms responding to this Sources Sought announcement, who fail to meet all requirements as stated above, and who fail to provide ALL the required information requested, will not be used to help the Government make the acquisition decision, which is the intent of this sources sought announcement.




Salient characteristics
(QTY 21) Patient Safety Lifts
All ceiling mounted hoists, rails, and components must comply with ISO 10535:2021
xy Systems Must be able to be flush mounted to a structural ceiling, integrated Into Suspended (Drop) Ceilings, or wall mounted. Cover 5m X 10m area with trainer (QTY 1) Cover 4m X 4m area (QTY 9) Cover 4m x 3m area (QTY 2) Cover 3m x 3m area (QTY 1) Linear Tracks Must be able to be flush mounted to a structural ceiling, integrated Into Suspended (Drop) Ceilings, or wall mounted. 3m Linear Track (QTY 3) Must be made from Aluminum 6063 T6 or better. Must have an anodized surface finish or better. Must support up to 550 lbs. or better
4m Linear Track (QTY 4) Must be made from Aluminum 6063 T6 or better. Must have an anodized surface finish or better. Must support up 825 lbs. or better 6m Linear Track (QTY 1) Must be made from Aluminum 6063 T6 or better. Must have an anodized surface finish or better. Must support up to 550 lbs. or better
Patient Lift Supports minimum 550 lbs. (QTY 17) Motor Speed: 60 millimeters every second or better. Horizontal Motor Option: Can include a motorized horizontal traverse along the ceiling rail, operated via hand control or IR remote. Digital System Integration: Supports Wi Fi connectivity for usage monitoring, service alerts, and data logging through a centralized digital platform. Safety Features: Includes mechanical and electrical emergency lowering, emergency stop, and overload protection. Manual Position Locks. Operating Noise: 50 to 60 dB(A). Battery System: Uses 24 V NiMH batteries with automatic activation, soft start/stop, and charge times of about 2 hours (for this capacity class). Main body dimensions: 580 mm × 345 mm × 156 mm. Impact resistant. Flame retardant housing. Continuous In-Rail Charging. LCD screen capable of displaying patient weight and lift usage information.
Patient Lift Supports minimum 825 lbs. (QTY 4) Motor Speed: 60 millimeters every second or better. Horizontal Motor Option: Can include a motorized horizontal traverse along the ceiling rail, operated via hand control or IR remote. Digital System Integration: Supports Wi Fi connectivity for usage monitoring, service alerts, and data logging through a centralized digital platform. Safety Features: Includes mechanical and electrical emergency lowering, emergency stop, and overload protection. Manual Position Locks. Operating Noise: 50 to 60 dB(A). Battery System: dual 24 V NiMH batteries with automatic activation, soft start/stop, and charge times of about 4 hours or better Main body dimensions: 580 mm × 345 mm × 156 mm. Impact resistant. Flame retardant housing. Continuous In-Rail Charging. LCD screen capable of displaying patient weight and lift usage information.
Medium Hanger Bar (QTY 21) Lifts up to 825 lbs. Four attachment points for a safe, stable, and comfortable lift. Works with ceiling and mobile lifts and fits standard slings. Strong, rust resistant metal covered with soft, easy to clean foam. Lightweight (4 lbs.) and easy to handle. Medium size (~24 wide) Trainer Module Motor (QTY 1) Reducing bodyweight, relieves up to 100 kg (220 lbs.), Built into the ceiling hoist added to system, controlled via the hand control interface. Safe exercise sessions: positioning lock and fall protection, enabling standing exercises, squats, steps, balance training, and sit-to-stand movements. 30-minute training limit: each session lasts up to 30 minutes per full battery charge, with clear indicators for weight relief and remaining time. After session, will automatically resume normal lift mode. Battery management: 1 hour of charge delivers about 10 minutes of training time. When training ends, it reverts to standard lifting and resumes charging. Installation (QTY 21) Install lift systems in 21 rooms. Labor and the hardware necessary to install the lift systems. Must support up to Level II that is identified in the Infection Control Risk Assessment (ICRA). Perform weight testing and certification of the installed lift systems. Removal of 18 existing lift systems. Design / Drafting (QTY 1) Stamped Engineering Calculations Slings (QTY 84) Support 450 lbs. or better Made from polypropylene material Disposable Limb Sling (QTY 1 per system) Disposable Basic High sling (QTY 1 per system) Disposable Twin Turner (QTY 1 per system) Disposable Repositioning Sling (QTY 1 per system) User Training (QTY 1)

More opportunities from Department Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)

Same awarding agency

NAICS: 561730
New
Federal
S208--Landscaping and Snow Removal Services
Solicitation # 36C24127Q0019
Solicitation 36C24127Q0019 is a combined synopsis and request for quotations issued by the Department of Veterans Affairs for landscaping and snow removal services at the Providence VA Medical Center, the VA Facility at 500 Valley Street, and the Harwood Center in Providence, Rhode Island. This procurement is a total set-aside for Veteran-Owned Small Businesses under NAICS code 561730. The contract structure consists of one base year and four option years, with an estimated start date of November 1, 2026. The scope of work encompasses comprehensive grounds maintenance, including lawn mowing, trimming, edging, and debris removal for approximately 5.28 acres, as well as snow removal, ice control for pedestrians and roads, and off-site snow hauling limited to 500 cubic yards annually. The government will utilize a comparative evaluation process to determine the best benefit, considering technical quality, past performance, and total evaluated price, including a six-month extension under FAR 52.217-8. Key deliverables include a snow removal logistics plan and strict adherence to acceptable quality levels, with 100 percent compliance required for snow and ice control services. Offerors must submit their responses by October 21, 2026, and must include a signed VA Notice of Limitations on Subcontracting Certificate of Compliance to be eligible for award. Invoicing is to be processed through the Tungsten Network. Amendment 0001 further refined the performance work statement, pricing structure, and provided industry clarifications regarding weather reporting and equipment protocols.
Landscaping Services

POSTED

2 days ago

DEADLINE

in about 12 hours
View Details
NAICS: 561720
New
Federal
S201--Janitorial Services CBOC'S
Solicitation # 36C24127Q0022
The Department of Veterans Affairs, Network Contracting Officer 1 New England, is soliciting quotes for janitorial services for four Community-Based Outpatient Clinics (CBOCs) located in Portsmouth, Conway, Tilton, and Somersworth, New Hampshire. This procurement is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 561720. The contractor will be responsible for providing all labor, supplies, chemicals, equipment, and supervision to perform routine cleaning tasks, including restroom sanitation, trash removal, dusting, vacuuming, mopping, and disinfection. The anticipated period of performance includes a base year starting December 1, 2026, with four subsequent one-year options extending through November 30, 2031. Award will be determined through a comparative evaluation of quotes based on price, technical capability, and past performance. To be rated acceptable, offerors must demonstrate corporate experience with at least one similar project within the last four years, provide a detailed technical approach and staffing plan, and submit three relevant references. Compliance with OSHA, JCAHO, and National Center for Patient Safety standards is required, and specific security credentialing guidelines apply to the Portsmouth location. Invoices must be submitted electronically via the Tungsten Program. Responses are due by November 3, 2026, at 10:00 AM EST.
Janitorial Services

POSTED

6 days ago

DEADLINE

in 13 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS