This Sources Sought opportunity from Department Of Veterans Affairs was posted on January 4, 2022. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6530--Guldmann GH3 Ceiling Hoist Brand name or equal

Closed
36C26022Q0169Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

Portland VA Medical Center 3710 SW US Veterans Hospital Rd, Portland, WA, 97239

Set-Aside

NONE

Documents

1

36C26022Q0169.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)
Contacts1 person available
OfficeVANCOUVER, WA, 98661, USA
Office AddressVANCOUVER, WA, 98661, USA
Contacts
Derek Crockett

Full Description

Show more
1 THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide the following services: The Portland VA Medical Center (VAMC) requires Prospective contractors to provide the Following: Guldmann GH3 Ceiling Hoist. Brand Name or Equal per FAR 52.211-6 Brand Name Or Equal to GH3 Ceiling Hoist manufactured by Guldmann. PART# DESCRIPTION QTY PATIENT LIFT SALIENT CHACTERISTICS 1. Patient Lift System Features The patient lift system being considered for award must meet the following specifications: In addition to compliance with ISO 10535 (Hoists for the transfer of disabled persons Requirements and test methods), the entire lift unit (not only the transformer) must be UL (Underwriters Laboratory) certified to meet requirements for user safety. Copy of certificate must be provided and copies of third party test reports should be made available upon request. Lifting speeds must be: 2.4 in/s (6.1 cm/s) at 330 lbs. (150 kg), 2.2 in/s (5.6 cm/s) in full capacity up to 880 lbs. (400 kg) The hand control must be wired, with LED screen capable of displaying patient weight (if scale option is purchased) and lift usage information. Scale must be internal; with patient weight displayed on a screen located on the hand control. Class III internal scale must be available as an option; with patient weight displayed on a screen located on the hand control. The hoist must not have an external scale attachment. Must be compatible for mounting on existing tracks (where applicable). Must have an emergency lowering pull cord that is easily accessible from standing person s height. Must have an additional emergency patient lowering option to safely lower patients without the use of tools. Must have a minimum three year warranty on lift units (including lifting straps and batteries) and washable slings. Warranty shall include all travel, labor and shipping associated with any warranty repair. Must have a wireless interface that connects to the existing Wi-Fi network infrastructure. Usage analytics and maintenance analytics software must have capability to be monitored remotely via web access, without the need for a physical connection cable. Lift must charge anywhere on the track via continuous AC charging. Lift must have capability to automatically provide hands free, dynamic body weight support and fall protection in real time during rehab or mobility sessions; clinical staff must be able to enter a specified offload weight directly into the hand control, after which the lift must continually offload the specified weight as patient moves and their center of gravity changes, without the need for staff to continue operating the hand control. Offload weight must be adjustable during a single session so that a patient can progress during that session. The hoist must use 24 V NiMH, 2.0 Ah rechargeable batteries Batteries provided will have a three-year warranty or better. Warranty shall include all travel or shipping associated with any warranty repair. The system will have visual and audio low battery indicator(s) and display total battery charges and current battery level. System must include a 2-point hanger bar without easily breakable parts such as rubber flaps or metal clips. 4-point hangar bar must be available. Hangar bars must be easily interchangeable without need of tools. Reusable slings must be washable and connect to the hanger bar via loops (not clips), and models must be available to support general transfers, hygiene, repositioning, turning, proning and gait training. Reusable slings must have a warranty of three years and include shipping. Disposable slings options must be available to must be available to support general transfers, hygiene, repositioning, turning and proning and gait training. The patient lift system should also meet the following specifications: Must have a capacity for lifting 550 pounds for standard rooms. Must have a capacity for lifting 825 pounds for bariatric rooms, using one cassette Should not beep or flash during normal operation to avoid alarming or disturbing staff and patients. The hoist trolley should move smoothly in the rail on 8 (frictionless) wheels. The emergency stop pull cord should be easily accessible from standing person s height. Lifting strap length should be 96 inches or more must be able to pick patients up off the floor. Must be modular with the ability to upgrade with additional features without buying new lift units. 2. Applicable model/make/catalog number Guldmann GH3+ 3. Manufacturer name Guldmann 4. Lift system solution must be provided by one manufacturer; multiple manufacturers for different areas or units will not be considered.

More opportunities from Department Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)

Same awarding agency

NAICS: 238220
New
Federal
J041--White City B249 SE HVAC Repair
Solicitation # 36C26027Q0102
Solicitation 36C26027Q0102 is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) issued by the Department of Veterans Affairs. The contract requires the repair of a Mitsubishi R-410A comfort-cooling system (Serial 07W0090) located on the southeast side of Building B249 at the VA Southern Oregon Rehabilitation Center and Clinics in White City, Oregon. The scope of work includes leak detection, brazing repairs with nitrogen purge, refrigerant recovery, evacuation to less than 500 microns, and recharging the system to nameplate requirements. The contractor must provide a detailed service report documenting the root cause, repair actions, and compliance with EPA Section 608 and VHA ICRA/PCRA controls for occupied healthcare facilities. The period of performance is 30 calendar days from the Notice to Proceed. Award will be granted to the responsible offeror whose proposal is most advantageous to the government, considering price and other specified factors. Key regulatory requirements include adherence to OSHA 29 CFR 1910.147 for lockout/tagout and 29 CFR 1910.333 for electrical safety. Payments will be processed via Electronic Funds Transfer, and invoices must be submitted electronically through the Tungsten Network. Offerors must provide their Unique Entity Identifier and maintain firm pricing for 60 calendar days from the response deadline of November 10, 2026.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

1 day ago

DEADLINE

in 12 days
View Details
NAICS: 334513
New
Federal
Boiler Plant O2 Sensor Replacement
Solicitation # 36C26027Q0101
The Department of Veterans Affairs, through the Network Contract Office 20, is conducting market research via a Sources Sought Notice for a firm-fixed price service contract to perform inspection, testing, maintenance, and repair of three model 6888 Rosemount flue gas analyzers. The work will be performed at the VA Southern Oregon Rehabilitation Center and Clinics in White City, Oregon. The primary scope involves replacing internal O2 analyzer components using original equipment manufacturer parts, specifically 18 inch standard cells, 18 inch heater strut assemblies, Hastelloy with Vee Deflectors for service up to 1300 degrees Fahrenheit, and new flange gaskets. The period of performance is six months, with on-site work required during core hours of 7:00 AM to 4:00 PM, Monday through Friday. This opportunity is designated as a total Small Business Set Aside under NAICS code 334513, with a size standard of no more than 750 employees. Qualified sources, including SDVOSB and VOSB entities, must provide company details, SAM.gov UEI numbers, and proof of manufacturer authorization if they are not the OEM. Contractors must employ qualified personnel, maintain general third-party liability insurance per FAR 52.228-5, and adhere to NEC, OSHA, and JCAHO standards. Deliverables include written daily reports to the Deputy Chief Facilities Management and testing documentation provided to the Contracting Officer's Representative. Interested parties are requested to provide a courtesy quote and capability statement to assist the government in evaluating price reasonableness and market availability.
Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables

POSTED

3 days ago

DEADLINE

in 4 days
View Details
NAICS: 325998
New
Federal
Microbiological media purchase order for Clinical Microbiology laboratory.
Solicitation # 36C26027Q0104
The Department of Veterans Affairs Network Contracting Office 20 is seeking sources for a microbiology testing media purchase order to support the Seattle Division of the VA Puget Sound Medical Center. This requirement covers a wide range of critical supplies for identifying pathogenic organisms in veteran patients, including long shelf-life products like Oxidase and Indole, perishable selective agar, biochemical test kits, and ATCC organisms mandated by the College of American Pathologists for quality control. The contract is structured with a base year running from February 1, 2027, to January 31, 2028, followed by four subsequent one-year option periods ending January 31, 2032. Deliveries are to be made to the Microbiology Lab in Seattle, with weekly shipments typically scheduled for Tuesdays and individual requests fulfilled as available. Due to the perishable nature of many items, the vendor must provide tracking information, and the cost of next-day delivery for all perishable goods must be included in the individual item price. All temperature-liable products require immediate refrigeration upon delivery. Invoicing is processed through the Austin Automated Payment System in Texas, and the vendor must provide SDS sheets for all media upon request. This sources-sought notice specifically looks for capable sources, including qualified SDVOSB/VOSB entities, with a response deadline of November 10, 2026.
All Other Miscellaneous Chemical Product and Preparation Manufacturing

POSTED

3 days ago

DEADLINE

in 12 days
View Details
NAICS: 238220
New
Federal
Z1DA--CON-NRM-668-22-106 Correct Domestic Water System
Solicitation # 36C26027R0014
Solicitation 36C26027R0014 is a negotiated request for proposals for the Department of Veterans Affairs to correct domestic water system deficiencies in Buildings 1 and 12 at the Mann-Grandstaff VA Medical Center in Spokane, Washington. The project is 100% set aside for Service-Disabled Veteran-Owned Small Businesses under NAICS 238220, with an estimated contract magnitude between $1 million and $2 million. The primary objective is to modify hot and cold potable water distribution systems to comply with VHA Directive 1061 for the prevention of scald injuries and Health Care-Associated Legionella Disease. The scope includes all labor, materials, and equipment, with a specific requirement to flush potable water dispensing fixtures twice weekly from installation until final acceptance. The period of performance is 275 calendar days from the Notice to Proceed. The government will utilize a Best Value tradeoff process for award, prioritizing technical experience and past performance over cost. Technical evaluations will favor offerors with demonstrated experience in phasing and Infection Control Risk Assessment (ICRA) within 24-hour operational emergency rooms. Proposals must be submitted in three separate volumes—Technical, Past Performance, and Price—by November 23, 2026. Awardees must provide performance and payment bonds, adhere to Davis-Bacon Act wage determinations, and comply with Buy American requirements. Additionally, the contractor must maintain strict confidentiality regarding sensitive information and provide a one-year warranty on all materials and installation.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

3 days ago

DEADLINE

in about 1 month
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS