This Sources Sought opportunity from Department Of Veterans Affairs was posted on May 7, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
6530--Roam 2-Compartment Aluminum Supply Cart
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
The Department of Veterans Affairs is seeking information from potential suppliers capable of providing four ERCP Roll-Top Door Carts with Hutch & Pegboard, designed specifically for Endoscopic Retrograde Cholangiopancreatography procedures at the VA San Diego Healthcare System. The carts must be constructed from lightweight aluminum composite, feature adjustable shelves and dividers compatible with 3", 6", and 9" trays, include a hutch and pegboard with at least twelve 4 to 6-inch hooks, a roll-top door with key lock, lockable casters for easy maneuvering in clinical spaces, and non-porous powder-coated surfaces cleanable with CaviWipes. The design must ensure staff visibility while pushing the cart and accommodate standard facility doorways and room layouts. This request is issued solely as a Sources Sought Notice under FAR 15.201(e), meaning it is not a solicitation and no contract will result from responses; all submissions are for market research and acquisition planning only. Respondents must provide a detailed capabilities statement addressing each salient characteristic, indicate their business size under NAICS code 339113 (800-employee size standard), disclose socioeconomic status such as SDVOSB, VOSB, HUBZone, or WOSB, and confirm whether they are the manufacturer, authorized distributor, or reseller. Companies must also affirm compliance with the Non-Manufacturer Rule, limitations on subcontracting under 13 CFR §125.6, the Buy American Act, and identify if their product qualifies as a Commercial Off-the-Shelf (COTS) item or has FDA clearance. Additional responses are required regarding lead time to delivery, estimated product lifespan, support services, leasing options, federal contract status, SAM.gov Unique Entity ID, and general pricing for market analysis. All responses must be submitted via email to Hestia.Sim@va.gov no later than May 8, 2026, by 10:00 AM Pacific Time. While no formal contract or evaluation factors exist at this stage, the information gathered will inform future procurement actions, potentially including a formal solicitation. Delivery, if a contract is later issued, will be to the VA San Diego Healthcare System with standard dock delivery.
General Info
Agency
NAICS
Place of Performance
Department of Veterans Affairs VA San Diego Healthcare System, San Diego, AZ, 92161, USASet-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
CLIN DESCRIPTION QTY UOM 0001 ERCP Roll-Top Door Cart w/ Hutch & Pegboard,2-3", 4-6", 2-9" trays with 12-6" Hooks 4 EA
Salient Characteristics Must be designed for Endoscopic Retrograde Cholangiopancreatography (ERCP) procedure supplies and accessories. Must be lightweight Aluminum composite construction Must have adjustable shelves, dividers, and bins that can be repositioned to match specific ERCP sets, such as cannulas, sphincterotomes, stents, balloons, guidewires, contrast, lead aprons, etc. Must have hutch & pegboard design for ERCP storage needs. Pegboard must have a minimum of twelve (12) units hooks that are 4 to 6 length. Pegboard must be the range of 36 to 36 Width and 12 to 16 Height. Must be customizable so the end users can customize based on procedure needs. Must be compatible with trays measuring 3 , 6 , and 9 height. Must come with two (2) 3" height trays Must come with four (4) 6" height trays Must come with two (2) 9" height trays with dividers Must have Roll-top door with a key lock. Must have casters that are lockable but also allow easy maneuvering in clinic spaces. Must have a handle to navigate the cart. Must be with a height that allows staff to maintain clear forward visibility while pushing the cart and enable access to store items without requiring excessive bending or reaching. Must have overall length and width dimensions that allow it pass through standard facility 43 W x 82 H doorways and hallways and maneuver within treatment rooms, including adequate turning radius clearance Must be fabricated with all non-porous surfaces. Must be powder coat paint for easy cleaning and durability. Must be able to clean with CaviWipes.
Standard Dock Delivery
Place of Performance: VA San Diego Healthcare System 3350 La Jolla Village Drive San Diego, CA 92161
The list of DRAFT characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required. If your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of salient characteristics requirements. For instances where your company cannot meet the salient characteristics requirement(s), please explain. For instances where your company can meet the salient characteristics requirement(s), please show how your company meets/exceeds each requirement. (2) Please review the list of salient characteristics requirements and provide any additional feedback or suggestions. If none, please reply as N/A. (3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc. (4) Is your company considered small under the NAICS code identified in this RFI? (5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of salient characteristics? (6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available). (7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified. (8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR § 125.6? (9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items? (10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? (11) Please indicate whether your product conforms to the requirements of the Buy American Act? (12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate. (13) What is estimated life span of your solution? What support/services does that entail? (14) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained. (15) Does your organization offer a leasing solution? Please elaborate. (16) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s). (17) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract. (18) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. (19) Please provide your SAM.gov Unique Entity ID/Cage Code number. Responses to this notice shall be submitted via email to Hestia.Sim@va.gov. Telephone responses will not be accepted. Responses must be received no later than Friday, May 8, 2026, by 10AM Pacific Local Time. All responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.
More opportunities from Department Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS
