The Program Contracting Office East plans to negotiate a sole source contract with Bruker Biospin Corporation to upgrade the existing Skyscan 1176 High Resolution In Vivo Micro-CT System. The upgrade includes procuring components that are fully compatible with the current system and software, such as a continuous variable X-ray source, an 11 Megapixel cooled digital X-ray CCD camera, and a 6-position automatic filter changer with highly purified filters. Key scanner capabilities include resolutions ranging from 9 to 35 microns, scanning diameters of 35 to 68 mm, and scanning lengths up to 200 mm with automatic connection of multiple scans. The system ensures radiation safety with exposure below 1 microSv/hour at the instrument surface. Accompanying physiological monitoring subsystems support real-time animal monitoring and synchronization with breathing and heart rate, along with appropriately sized carbon composite beds for various animals, including mice, rats, and rabbits. The computer hardware required to operate this upgraded system is a high-performance Dell workstation equipped with a quad-core Intel XEON processor, 128 GB of RAM, 4TB RAID storage, and a 2GB NVIDIA graphics card, running Windows 7 or higher. Essential software packages include GPU-accelerated and hierarchical reconstruction programs for rapid and accurate data processing, visualization tools allowing flexible 2D and 3D rendering, and format converters including DICOM compatibility for image file management. Functional analysis software supports detailed morphometric evaluation, while multiple visualization applications enhance 3D model interaction and presentation. Interested vendors with compatible equipment were invited to express interest by a specified deadline, after which the contracting officer would decide on proceeding with a competitive process or sole source negotiation with Bruker Biospin Corporation.

General Info

Sole source contract to upgrade Skyscan 1176 Micro-CT system with compatible hardware, software.

Agency

N/A

NAICS

334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing

Place of Performance

Not specified

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

special-notice

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyN/A
ContactsNo contacts available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
The PCO-EAST (Program Contracting Office) East intends to negotiate on a sole source basis with Bruker Biospin Corporation , 15 Fortune Drive, Billerica, MA 01821-3991to procure equipment to upgrade the existing Skyscan 1176 High Resolution In Vivo Micr-CT System. The following items will be required to upgrade this system and are compatible with the existing system and software currently in use. Scanner specifications 1) X-ray source: Continuous variable source from 20 kV to 90 kV, 15 micron typical spot size; 25 W maximum power, air cooled sealed type. 2) X-ray detector: 11 Megapixel (4000 x 2670) 12-bit cooled digital X-ray CCD camera with fiber-optic coupling to scintillator. 3) 6-position automatic filter changer for energy selection: no filter, Al 0.2mm, Al 0.5mm, Al 1mm, Al 0.5mm + Cu 0.03mm, Cu 0.1mm (all filters > 99.9% purity). 4) Nominal resolution (detail detectability): 9 micron / 18 micron / 35 micron 5) Low contrast spatial resolution: 15 micron (10% MTF) 6) Scanning diameter: 68mm or 35 mm 7) Scanning length: up to 200mm by multiple automatically connected scans, 20mm in one scan 8) Reconstruction arrays: cross section format (isotropic grip): up to 4000 x 4000 pixels for 35mm field of view (FOV) and up to 8000 x 8000 pixels for 68mm FOV. 9) Radiation safety: < 1microSv/h average during full scan at instrument surface Physiological monitoring subsystem specifications: 1) Capabilities include real-time visual monitoring, movement detection, synchronization with small animal (rodent) breathing and heart activities, and stabilization of preselected animal temperature. 2) Carbon composite bed for mouse (35mm), for rat (68mm), and bed with tray (580 x 470mm) for large animals (rabbit). 3) Foam holders for ex-vivo and peripheral scanning. Computer specifications - The following computer (specifications) are required to operate the scanner and perform necessary analyses: 1) Internally mounted Dell Workstation with preinstalled software including: a. Windows 7/64 bit or above. b. Intel XEON X5647 quad core 3.5GHz processor c. 128 GB 1600 MHz RAM d. 4TB (4 x 1TB on RAID0) HDD e. 2GB NVIDIA graphical card f. 24" UltraSharp LCD monitor, 1920 x1200 native resolution g. DVD/CD RW optical drive h. Keyboard i. Mouse j. Internal speaker or sound bar Software specifications - The following software is necessary to operate the scanner and perform necessary analyses: 1) NRecon - GPU-accelerated data reconstruction software compatible with Windows 7 or above. Uses modified Feldkamp multi-slice volumetric (cone-beam) reconstruction algorithm. 2) InstaRecon - Heirarchical reconstruction software compatible with Windows 7 or above. Uses unique (non-Feldkamp) reconstruction algorithms with speedups of 10x to > 100x. 3) DataViewer - Visualization software that allows the reconstructed set of slices to be flexibly viewed and displayed as a slice-by-slice movie. 4) TConv and DICOM converter - Format converting software allows conversion between TIFF, BMP, and JPEG files with adjustments of color palette, inversion, renaming, resizing, and combining datasets. The DICOM converter provides conversion from the set of reconstructed slices to file(s) in DICOM 3 format. 5) CTan - Morphological analysis software measures comprehensive 2D and 3D morphometric parameters. 6) CTvol - Visualization software provides viewing, intuitive and flexible control of 3D-model texture, transparency, and versatile moviemaker. 7) CTvox - Visualization software provides 3D volume rendering visualization (using a different approach than CTvol). This notice of intent is not a request for competitive proposals. Any responsible sources who wish to identify their interest and capability to provide this equipment or equipment that is compatible must notify this Contracting Officer at contact@example.gov NLT Monday October 26, 2015 by Noon EST. Telephone responses will not be accepted. Upon receipt of the interested parties' notification, the Contracting Officer will determine whether to conduct a competitive procurement or proceed with sole source negotiations.

Similar Contracts

Same NAICS industry code

NAICS: 334510
New
DIBBS
VENTILATOR, VOLUME, PORT
Solicitation # SPE2DS-27-Q-0026
Solicitation SPE2DS-27-Q-0026 is a fixed-price request for quotations issued by DLA Troop Support Medical Supply Chain for the procurement of two portable EMV Plus volume ventilators (NSN 6515-01-586-5898). These units must include an internal battery charger, a 3-liter oxygen reservoir kit, and a military manual. Technical specifications include a weight of approximately 9.5 lbs, an operating voltage range of 100 to 240 VAC and 11 to 33 VDC, and an operating temperature range from -13 to +167 degrees Fahrenheit. This is a Foreign Military Sales requirement for Taiwan, with delivery required within 30 days after receipt of the order and a customer required delivery date of September 29, 2026. The contract mandates strict adherence to medical packaging and marking standards, specifically Medical Marking Standard No. 1, which supersedes MIL-STD-129. Items must be provided in sealed unit containers and commercial exterior shipping containers per MIL-STD-2073-1E. Item Unique Identification (IUID) is required in accordance with MIL-STD-130 and DFARS 252.211-7003. Inspection and acceptance are set at origin, and all invoicing must be processed electronically via Wide Area Workflow as a receiving report and invoice combo, including a Certificate of Conformance. This procurement is not a small business set-aside and incorporates various FAR and DFARS clauses regarding the Buy American Program, cybersecurity reporting, and sustainable products. Quotations are due by November 6, 2026.
MEDICAL SUPPLY CHAIN MD SURG FSF

POSTED

about 6 hours ago

DEADLINE

in 7 days
View Details
NAICS: 334510
New
Federal
Electro-Therapeutic Modalities for Pain Management (ETMPM) - Transcutaneous Electrical Nerve Stimulation (TENS) Procurement Program
Solicitation # 36C79126R0011
The Department of Veterans Affairs is soliciting proposals under Solicitation Number 36C79126R0011 to establish multiple single-award, Firm-Fixed-Price, Indefinite Delivery/Indefinite Quantity (IDIQ) base contracts for the Electro-Therapeutic Modalities for Pain Management (ETMPM) and Transcutaneous Electrical Nerve Stimulation (TENS) Procurement Program. This national program provides FDA-cleared electro-therapeutic devices and accessories to support non-opioid pain management across 168 VA Medical Centers and over 1,000 Community-Based Outpatient Clinics. The scope includes portable TENS units, portable Interferential Current (IFC) devices, thermal and non-thermal Short-Wave Diathermy (SWD) devices, and portable neuromodulation systems for headache disorders, along with associated consumables such as electrodes and lead wires. The procurement utilizes a VA Tiered Set-Aside Evaluation Approach, prioritizing Service-Disabled Veteran-Owned Small Businesses (Tier 1), followed by Veteran-Owned Small Businesses (Tier 2), other small business concerns (Tier 3), and finally other-than-small business concerns (Tier 4). Evaluation methodologies vary by item: CLINs X001 through X004 are awarded based on Lowest Price Technically Acceptable (LPTA) procedures, while CLIN X005 is evaluated using a Best-Value Tradeoff method, weighting technical factors at 60 percent, price at 25 percent, and past performance at 15 percent. Responsive proposals must include a signed SF 1449, a Technical Capability Statement, FDA 510(k) clearance letters, and three past performance documents. Non-manufacturers must provide OEM-issued Authorized Distributor Letters. Mandatory certifications include the Price Matrix (Attachment 0001), Limitations on Subcontracting (Attachment 0003), and either the Buy American Certificate (Attachment 0004) for small businesses or the Trade Agreements Certificate (Attachment 0005) for large businesses. Product samples for every offered CLIN/SLIN must be shipped to the Denver Logistics Service facility. Following several amendments, the final deadline for the receipt of all proposal documentation and product samples is November 2, 2026, at 12:00 PM CDT.
Commodities & Services Acquisition Service (36C791)

POSTED

about 11 hours ago

DEADLINE

in 3 days
View Details
NAICS: 334510
New
Federal
Hearing Aid Fitting and Verification for Shiprock Service Unit (IEE or ISBEE Set Aside)
Solicitation # SS-SRSU-27-0003
The Indian Health Service Shiprock Service Unit is conducting market research through a sources-sought notice to identify capable Indian-owned economic enterprises, both large and small, to provide hearing aid fitting and verification services. The primary objective is to reduce hearing aid rejection and costly remakes while ensuring patients receive optimal benefit from their devices. The requirement includes the provision of equipment with advanced technical specifications, such as dual ear capability, a frequency range of 200 to 16,000 Hz, and a comprehensive test suite including speechmap counseling and pediatric probe tube placement. Additionally, the selected vendor must provide installation and training for the Audiology Department. This opportunity is categorized under NAICS code 334510 for electronic hearing aid manufacturing. In accordance with the Buy Indian Act, the government will prioritize responses from Indian-owned economic enterprises before considering other small business set-aside programs. Interested parties must be registered in the System for Award Management and submit a company profile, a capability statement, and a completed IHS IEE Representation Form by November 03, 2026. This notice is for market research purposes only and does not constitute a formal solicitation.
Navajo Area Indian Health Svc

POSTED

2 days ago

DEADLINE

in 4 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS