Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity was posted on March 13, 2007. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

66 -- Vacuum Leak Detector

Closed
FA8601-07-T-0024Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334512
New
DIBBS
THERMOSTAT, FLOW CONTRO
Solicitation # SPE4A5-27-T-1389
Solicitation SPE4A5-27-T-1389 is a federal procurement issued by the DLA Weapons Support ASC Supplier Oper OEM Division for the acquisition of 63 flow control thermostats, identified by NSN 6685-12-360-1961. The requirement specifies several compatible part numbers from manufacturers including IML Motori SRL, Deutz AG, and Augusta Engine Parts, Inc. The items are designated as critical application items and must be delivered FOB Origin to DLA Distribution Cherry Point in North Carolina. The need ship date is April 13, 2027, with an original required delivery date of April 25, 2027. The contract mandates strict quality and packaging standards, requiring compliance with MIL-STD-2073-1E for packaging and MIL-STD-129 for marking, specifically utilizing special marking code 05 for delicate instruments. Inspection and acceptance will occur at the destination, with sampling conducted according to MIL-STD-1916 or ASQ H1331. Administrative requirements include electronic invoicing via the Wide Area WorkFlow system and adherence to the Hazard Communication Standard for any hazardous materials. The procurement is governed by the DLA Master Solicitation for Automated Simplified Acquisitions Revision 105 and prohibits the use of additive manufacturing unless specifically authorized. Evaluation may include a HUBZone price preference, and the buy is identified as a candidate for automated award.
DLA WEAPONS SUPPORT ASC SUPPLIER OPER OEM DIVISION

POSTED

1 day ago

DEADLINE

in 6 days

General Info

Agency

N/A

NAICS

334512 - Automatic Environmental Control Manufacturing for Residential, Commercial, and Appliance Use

Place of Performance

AFIT ENY2950 Hobson Way WPAFB, OH 45433

Set-Aside

SBA

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts1 person available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts
James A LeightyContract Specialist

Full Description

Show more
This is a request for quotations (RFQ) for commercial purchase of a Vacuum Leak Detector for Wright-Patterson AFB in Dayton, OH. No other solicitation or announcement will be made. This RFQ is issued under simplified acquisition procedures using the authority of FAR 13.5. SET ASIDE: 100% small business set-aside. All small businesses are encouraged to participate in this procurement. The size standard for this effort is 500 employees. NAICS: 334512 FSC: 6625 DELIVERY: To be negotiated with the requiring activity. The attached RFQ shows a preliminary delivery date of no later than ?30 days after date of contract.? Please provide your payment terms and any discounts you are offering. AWARD: Award will be made to the lowest-priced technically acceptable Offeror. QUOTATIONS: Submit your quotation to James (Andy) Leighty at james.leighty2@wpafb.af.mil. Quotes are due by midnight, 20 March 2007. QUESTIONS: Questions on this procurement may be directed via email to Andy Leighty at james.leighty2@wpafb.af.mil or (937) 522-4593. Minimum Requirements For Vacuum Leak Detector Minimum Requirements: Time To Test: <1.5 sec. on a blank test port. Sensitivity: 4 x 10-11 atm cc/sec. in direct mode.* 4 x 10-10 atm cc/sec, in reverse mode.* Response Time: Direct Mode <2 seconds.* Reverse Mode <3 seconds.* Leak Range: 10-4 atm cc/sec. to 4 x 10-11 atm cc/sec. 10 atm cc/sec. to 4 x 10-11 atm cc/sec. with optional dedicated external roughing pump. Resolution: Resolving power of 14 at mass 4.* Maximum Inlet Pressure: Test Mode: Atmosphere Gross (with dedicated external roughing pump) 7.5 Torr Fine Start Up Time: <3 minutes. Turbo Pump: 52 Vsturbomolecular pump with ceramic bearing. Mechanical ForelinelRoughing Pump: Built-in 1.5 cfm direct drive foreline/roughing pump. Optional 7 cfm or 16 cfm auxiliary roughing pump available. Valves: Reliable, fast acting solenoid valves rated for millions of cycles. Easy to clean without special tools, designed for long, trouble-free life. Vacuum Gauging: Two Pirani gauges monitor foreline and test port pressures. An ionization gauge is built into the spectrometer tube ion source for reduced maintenance. A built-in, maintenance-free HiVac gauge utilizes existing focusing plates within the source and eliminates the need for a high maintenance cold cathode discharge gauge. Access: Hinged doors and pop-off side panels for serviceability of pump oil, air filters and internal calibrator. . Calibrator: Internal temperature compensated Helium leak standard. Traceable to NIST with quick disconnect for easy recalibration. Spectometer Tube 180? deflection dual magnetic sector mass spectrometer tube with builtin high vacuum ion gauge. Two long-life, low current filaments. Selfcleaning heated repeller and automatic closedloop emission control. Heavy ion traps reduce the need for deionization of the mass spectrometer tube by an order of magnitude. Tunable: Sensitive to Helium Mass 3 or Mass 4, user selectable. Electronics: Microprocessor controlled. Diagnostics automatically display error codes and messages on alphanumeric display. Real time clock with battery back-up. RS-232 Port: Provides for remote computer control and data transfer, as well as remote diagnostics and downloading of new software releases directly from VIC. Uniform field lengths allow for easy integration and downloading of data into automated systems. Printer Port: A parallel printer port is provided to transmit test results to any PC compatible printer. At the conclusion of a test, the leak rate, the reject set point, reject or accept indication, and the time and date is sent to the printer. -n- _u- Service/Maintenance Panel: A flip-open door provides easy access to settings and diagnostic functions for maintenance personnel..A switch inside the unit enables the service mode, which prevents unauthorized access. Total unit running time is monitored for scheduled Operator Interface Control Panel: User-friendly, highly reliable sealed membrane switch panel. All necessary test information is clearly displayed on the control panel. Diagnostic and set-up information shown on 8-digit alphanumeric display. Audio leak rate indicator with volume control. Tuning Controls: Single button for completely automatic tuning. Cal Check button verifies tuning and calibration at any time. Single calibrate button adjusts gain automatically. Hand-Held Remote Control Option: Remote unit provides start/vent switches and ranging controls along with leak rate readout up to 100 feet trom the leak detector. Highly reliable tactile membrane switches and lightweight rugged design. Standard coiled cord length of 25 feet. Physical Data Size: 15"H x 20112"W x 14"D (38.1 em H x 52.7cm Wx 35.6 em D). Weight: 871bs. 39.5 kg. (MS-40); 961bs. Power Requirements: 115V, 60Hz, 8 amps. .

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown