GENERAL REQUIREMENTS: Contractor should provide CPRR pricing for sites with existing equipment. CPRR pricing will include reagents, service and maintenance of analyzers and data manager systems. CPRR pricing would provide if the solution presented does not allow for use of existing equipment. CPRR will include all components (reagent, equipment, data manager system, service, etc.) necessary to allow for release of a test result into the VISTA computer system.
Operational Features- The instrumentation offered shall have the capability to perform; Creatinine testing. eGFR result must be calculated on board the analyzer at the time of testing Calculation for eGFR must be performed using MDRD Equation. Creatinine testing must a method that has calibration traceable to an IDMS reference measurement procedure. Methods based on either enzymatic or Jaffe method principles should have calibration traceable to IDMS. Cards must allow for testing of both venous and arterial blood sources. Ability to perform testing at locations that are remote from the laboratory. This may include hospital clinic, emergency department, operating room or Community Based Outpatient Clinic locations (CBOC). Meters must be portable or singlehanded use Technical Features The instrumentation must be approved by the Food and Drug Administration (FDA) and shall have the following: Testing cannot be High Complexity testing by CLIA definitions. Operator and patient identification tracking. Products must be compatible with the wireless EPOC point of care analyzers in place at Kansas City VAMC. Expired operator, failed quality control and invalid lot number instrument lock out. Ability to detect poor reagent or strip integrity. Capillary, arterial, and venous sample options. No requirement for micropipette for application of blood for capillary test option. Capability to add user configurable comments. Maintenance for end users should be minimal and easily documented. Vendor should supply documentation detailing maintenance requirements. Ability to correlate Creatinine values with main laboratory instrumentation within +/- 20%. Interface Requirements The Contractor shall be responsible for providing all hardware required for the connection, implementation, and operation of the interface to the universal interface. The Contractor shall provide all necessary software support for ensuring that successful interfacing has been established. Specific requirements for the communication of the data streams will be unique to the instrument system involved and dictated by the manufacturer itself. Information necessary to make the determination for type and amount of interfacing equipment is supplied in Attachment A. If a site already has a universal interface box, the Contractor is responsible for everything leading up to the box including any incremental fee required to add additional equipment (e.g., licenses, ports/cards, cables, software, etc.) to the universal interfacing system. If a site does not have a universal interface and one is needed to optimally interface the instrument, then the Contractor is responsible for the acquisition of the universal interface box and everything else needed to connect with VA computerized hospital information system. If there are any software upgrades in the instrument during its life, the Contractor is responsible for seeing that the interface can accommodate any changes in the data stream going to the VA computerized hospital information system. Hardware Features- The instrumentation shall have the following: Downloader and rechargers must be provided if required as part of the testing system. Existing equipment as specified in Attachment A. The contractor shall provide full maintenance both remotely and onsite to include all replacement parts, software updates, labor, travel expenses, tools, test equipment and other incidentals necessary to maintain or restore the existing data manager to operating specifications which meet or exceed the manufacturers specifications for existing equipment. If existing equipment malfunctions, the contractor will be contacted by the facility to provide a replacement unit as part of this agreement. All parts used must be new or factory rebuilt for that model and type of device. If any action requires replacement of a hard drive or other storage media, the contractor shall not remove the hard drive/storage media from the VA premises and must turn over said device to the facility. All services for this contract must meet manufacturers performance and technical specifications, Federal Regulations, FDA device certification and other specifications that may apply such as National Electric Code (NEC), Life Safety Code (LSC), the Joint Commission (JC), and VA Regulations. Contractor must provide the appropriate service documentation at no additional expense. Contractor shall provide hardcopy proof, upon request of COR, that contracting entity is a certified manufacturer service provider ant that technicians are current in device certification training. Contractor service representative shall report to the Engineering Offices upon arrival on station to be issued a temporary VA Contractors ID badge and shall wear the VA issued ID badge above the waistline at all times while on the premises. Rechargeable batteries should be included. If device functions utilizing wireless technology, the device must have FIPS-140-2 certification. Vendor must supply the following documentation for all analyzers and data management systems proposed to VISN 15: MDS2 - Manufacturer Disclosure Statement for Medical Device Security. VA Directive 6550 Appendix A- Pre-Procurement Assessment FIPS-140-2 Certification for Wireless technology MOU/ISA for Data Management systems that will require vendor access. Method Performance/Validation Requirements Method performance/comparison shall be at the expense of the Contractor, shall include linearity material and reagents, and be consistent with current CLSI guidelines and related documents, College of American Pathologists (CAP) standards and Federal regulations. Correlation studies for each analyte. A minimum of 20 samples spanning the reportable range shall be run by the present and the proposed method. In systems where multiple sampling modes exist, mode to mode correlation studies must also be performed. Contractor shall provide technical support specialist to assist with studies and to analyze results and provide statistical data to support acceptance of the new method for above studies. Statistics shall consist of at least mean, bias, slope, y-intercept, correlation coefficient, and meet current standards defined by CLSI. Analytical Measurement Range (AMR) Validation shall be performed on proposed instrument(s) for each analyte to validate the reportable range. The material must have values, which are near the low, mid, and high values of the AMR and be of appropriate matrix for the clinical specimens assayed by that method Precision study using normal and abnormal control material. This shall consist of a within run precision study of 10 normal and 10 abnormal controls and a day-to-day precision study of normal controls and abnormal controls for 10 days (may be run twice a day) for a total of 20 values per level of control. Intra-VISN facility variations should be kept at an absolute minimum. Sensitivity. Sensitivity may be validated concurrently with correlation studies. Mathematical calculations to determine efficiency, sensitivity, false positive rate and false negative rate are applied. Specificity Studies. A review of product literature and assay inserts to determine any adverse effects for increased bilirubin, hemolysis, lipemia, or other interfering substances. The Contractor shall provide all start up reagents required to establish instruments for operation for performance of acceptance testing. Testing will not be implemented at the individual facilities for the selected system if the validation fails statistical studies as determined by the facility Pathology & Laboratory Service Chief. Reference Range- A reference range must be determined for each test following CLSI guidelines. Samples used for the reference range study must be representative of the patient population being tested. Reference range assessment must be performed for each lab. One of the following protocols shall be used: A verification of the manufacturer s suggested reference range may be performed as long as the suggested range is based on a comparable population of test subjects. The manufacturer shall provide specific information defining how the suggested range was determined. A minimum of 20 reference individuals shall be used to verify the manufacturer s range. Any apparent outliers should be discarded, and new specimens obtained to provide a statistically valid verification. If the suggested manufacturer s range is not appropriate for the patient population, a reference range shall be established. Establishing a reference must follow CLSI guidelines. This requires a minimum of 120 reference individuals to be used to establish a reference range. The reference interval should be determined using the nonparametric method. If a laboratory is currently using the proposed instrument/reagent system, the in-use reference range can be transferred to the new system if a method comparison study between the two systems proves to be acceptable. If comparison studies are not acceptable, one of the two above items must be performed. Support Features The equipment models being offered shall be in current production as of the date this offer is submitted. For purposes of this solicitation, current production shall mean that the clinical laboratory analyzer model is being offered as new equipment. Discontinued models that are only being made available as remanufactured equipment are not acceptable. Start-Up Reagents. The Contractor shall provide all reagents, calibrators, controls, consumable/disposable items, parts, accessories and any other item included on the list of supplies defined in the Federal Supply Schedule contract and required to establish instruments for operation for performance of acceptance testing. The Contractor shall perform, to the satisfaction of the Government, all validation studies including precision, method comparison with current analyzer, accuracy (recovery), calibration verification, verification of reference interval, and determination of sensitivity and specificity at no cost to the Government. The Contractor shall perform all of the statistical analysis as stated in the Method Performance/Validation section above and report data in an organized, clearly comprehensible format. Training. The Contractor shall provide an instrument training program that is coordinated with and timely to the equipment installation, sufficient to the size and scope of the facility s services and minimally equivalent to the terms and conditions for training defined in the Contractor s Federal Supply Schedule FSC Group 66, Part III, Cost-Per-Test Clinical Laboratory Analyzers contract. This shall include training on the operation of the system, maintenance, quality control, limitations of the test, data manipulation, and basic trouble shooting and repair, as applicable, to nursing, pharmacy and/or laboratory personnel. Service Requirements Equipment Preventative Maintenance/Repair Service. The Contractor shall be able to provide emergency equipment repair and preventative maintenance on all primary and back-up instrumentation and any incremental support equipment, e.g., water system, offered according to the following terms: A technical assistance center shall be available by telephone 24 hours per day, 7 days per week with maximum call back response time of 1 hour. The contractor shall provide the necessary information to replace an inoperable device. This replacement shall include meters, charging bases, and rechargeable batteries at no additional cost. A minimum acceptable service shall also include replacement delivery of items to be replaced with overnight service, but no longer than one (1) business day from the time-of-service ticket confirmation. Upgrades - The Contractor shall provide upgrades to the equipment hardware, bidirectional interface and software in order to maintain the integrity of the system and the state-of the art technology, at no additional charge to the Government if sites are interested. These shall be provided as they become commercially available and at the same time as they are being provided to commercial customers. This requirement only applies to system upgrades that enhance the model of equipment being offered, i.e., new version of software, correction of hardware defect, upgrade offered to commercial customers at no additional charge, upgrade to replace model of equipment no longer Contractor supported, etc. This does not refer to replacing the original piece of equipment provided under the contract; however, it does refer to significant changes in the hardware operational capability. Ancillary support equipment - The Contractor shall provide, install and maintain through the life of the contract, as indicated, any and all ancillary support equipment to fully operate the analyzer as defined in these specifications, e.g. rechargeable batteries. In addition, the Contractor shall include all ancillary components that are customarily sold or provided with the model of equipment proposed, e.g., starter kits.
Important information: The Government is not obligated to, nor will it pay for or reimburse any costs associated with responding to this source sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to an acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. Currently a total set-aside for Service-Disabled Veteran Owned Small Business firms is anticipated based on the Veterans Administration requirement with Public Law 109-461, Section 8127 Veterans Benefit Act. However, if response by Service-Disabled Veteran Owned Small Business firms proves inadequate, an alternate set-aside or full and open. Any response to this source selection from Interested parties must be received NLT 03/10/2026, 3:00 PM CST. Attention: Michael Murphy, Contract Officer Email: Michael.murphy7@va.gov Additional Important Information: Interested persons shall reference 36C25526Q0183 Creatine Testing in the subject line of all emails.
Only organizations with an active SAM.GOV account can be considered.
Utilize this link to either start a new registration or to renew the organization s registration.
Responses to this notice shall include the following responses for all the questions or requests (a) thru (s) in order to be considered for this acquisition: (a) Company Name _______________________________________________ (b) Address_______________________________________________________ (c) Point of Contact ________________________________________________ (d) Phone, Fax, and Email____________________________________________ (e) UEI number ____________________________________________________ (f) Cage Code_________________________________________________________ (g) Tax ID Number ________________________________________________________ (h) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB)_____________________ Veteran Owned Small Business (VOSB)_______________________ Hubzone________________________________ Woman Owned Small Business (WOSB)___________________________ Large Business___________________________________ Is your company considered small under the NAICS code identified under this SSN/RFI?
Yes______ No________
(j) Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above?
Yes______ No________
(k) If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of contact.
Designated Distributors Company POC Phone Email
(l) If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way?
Yes______ No________
If you do, state how and what is altered; assembled; modified?
Response:_____________________________________________________________________
(m) If you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Subcontract Yes______ No________
Portion of Total Cost:_______________________
Please provide estimated detailed percentage breakdowns related to subcontracted work. Response:_________________________________________________________________ __________________________________________________________________________ (n) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract number.
Yes______ No________
Contract #_________________________________
(o) If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract?
Yes______ No________
(p) Please provide general pricing of your products/service for market research purposes. Product/Service Unit Unit Price Amount
Important (s) Must provide a statement of capability that clearly addresses the organization s qualifications and ability to perform as a contractor for the work described.
More opportunities from Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS