This Solicitation opportunity from Department Of Veterans Affairs was posted on August 21, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6640--Request for Reagents and supplies as part of a Cost Per Test (CPT/CPRR). This testing is for Veterans across WA, OR, and AK. More details available in Statement of Work in RFI.

Closed
36C26026Q0015Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 325413
New
DIBBS
CULTURE MEDIUM, THAYER-
Solicitation # SPE2DS-27-T-1066
Solicitation SPE2DS-27-T-1066 is a request for quotations issued by the DLA Troop Support Medical Supply Chain for the procurement of one package of Thayer-Martin Modified (MTM II) Agar culture medium, identified by NSN 6550-01-711-1542. This dark brown, ready-to-use plated medium is specifically designed for the isolation of pathogenic Neisseria from specimens containing mixed flora of bacteria and fungi. The product is delivered in packages of 100 plates and requires strict refrigeration storage between 2 to 8 degrees Celsius (36 to 46 degrees Fahrenheit) and must not be frozen. The contract mandates a non-extendable shelf life of three months, with a requirement that no more than 14 days elapse between the date of manufacture and the date of delivery to the government. Delivery is set for JBER, Alaska, with a required delivery date of October 27, 2026, under FOB Destination terms. Packaging must be commercial and sealed to prevent damage, with marking adhering to Medical Marking Standard No. 1 and shelf-life labels following MMS1C. Administrative requirements include electronic invoicing via the Wide Area WorkFlow system and compliance with various FAR and DFARS clauses, including the Buy American Act, Berry Amendment, and safeguarding of covered defense information. Evaluation will consider technical data for any alternate products offered and may include HUBZone price evaluation preferences. Inspection and acceptance will occur at the destination.
MEDICAL SUPPLY CHAIN MD SURG FSF

POSTED

1 day ago

DEADLINE

in 5 days
NAICS: 325413
New
Federal
6550--Optilite analyzer reagents
Solicitation # 36C26227Q0052
The Department of Veterans Affairs, Southern Arizona Healthcare System, is soliciting a Firm-Fixed Price Blanket Purchase Agreement under solicitation 36C26227Q0052 for the procurement of FDA-approved reference testing reagents and consumables validated for use on the Optilite analyzer. The scope includes specific items such as Freelite Kappa, Freelite Lambda, and Ceruloplasmin reagents, as well as TENCELL cuvettes and sample cups. To ensure system performance and safety, all materials must be manufactured by Binding Site Laboratories, and substitutions are prohibited. The contract is issued as a full and open competition under NAICS code 325413, with a total estimated period of performance of sixty months, consisting of a base period from November 9, 2026, to November 8, 2027, followed by four one-year option periods. The award will be granted to the responsible offeror whose proposal is most advantageous to the government, based on a technical acceptability review of the Statement of Work and the lowest price. Deliveries are required to be made to various VA Medical Centers across Arizona, California, and New Mexico, with standard orders delivered within four working days of placement. All shipments must be destination-based, with the vendor assuming all shipping costs and adhering to strict packaging standards to prevent damage. Invoicing is handled electronically through the Department of Veterans Affairs Financial Services Center in accordance with the Prompt Payment Act. Quotes must be submitted via email to Contract Specialist Carlos Magana by November 4, 2026.
262-NETWORK Contract Office 22 (36C262)

POSTED

3 days ago

DEADLINE

in 6 days
NAICS: 325413
New
Federal
BPA - Consumable Supplies for Terumo Trima Accel Blood Collection systems
Solicitation # HT942627QE003
The Defense Health Agency is soliciting quotations to establish a Blanket Purchase Agreement (BPA) for the recurring resupply of consumable products for three Terumo Trima Accel Blood Collection Systems used by the USAISR Combat Casualty Care Research Team 1 in Texas. To maintain FDA approval and satisfy research protocols, the contractor must provide original manufacturer-supplied consumables, including Teruflex 500ml collection bags, Trima Platelet Kits, Isoplate Solution (PAS-F), TSCD Wafers, ACD-A Solution, and 150 mL couplers. This procurement is a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS 325413. The resulting BPA will have a 60-month ordering period with a total ceiling of 35 million dollars, though some documentation notes a lower limit of 350,000 dollars. Individual call orders are capped at 50,000 dollars, while Government Purchase Card orders are limited to 15,000 dollars. Awards will be made on a Lowest Price Technically Acceptable basis, with technical capability rated as pass or fail. All payment requests and receiving reports must be processed electronically through the Wide Area WorkFlow system. Quotations are due by November 6, 2026, and must be submitted in two separate volumes covering technical capability and pricing.
Army Medical Resources Acq Activity

POSTED

7 days ago

DEADLINE

in 8 days
NAICS: 325413
Federal
6550--VISN Cepheid GeneXpert Testing Supplies Base Plus 3 Op Yr RFQ
Solicitation # 36C24527Q0042
The Department of Veterans Affairs, specifically the VA North Atlantic Health Network (HSA 1.3), is soliciting a firm-fixed-price, Indefinite Delivery/Indefinite Quantity (IDIQ) contract for Cepheid GeneXpert testing supplies. This requirement covers the procurement of FDA-approved reagents, consumables, and service for PCR analyzers to detect various pathogens, including CoV-2, Influenza, RSV, MRSA, and Mycobacterium Tuberculosis. The contract is structured with a base period ending October 31, 2027, and three subsequent one-year option periods extending through October 31, 2030. Deliveries will be made to multiple VA Medical Centers across Maryland, West Virginia, and Washington DC. This acquisition is set aside for HUBZone small businesses. Award will be determined using the Lowest Price Technically Acceptable (LPTA) method, evaluating technical acceptability, delivery performance, past performance, and price, with additional credit given to certified SDVOSB or VOSB offerors. Key contractor requirements include being an authorized distributor, acknowledging orders within 24 hours, and guaranteeing a minimum four-month expiration date on reagents. Additionally, the vendor must provide an emergency plan to deliver replacement supplies within 24 hours if products are found to be defective. Invoices must be submitted electronically, and payments will be processed in accordance with the Prompt Payment Act.
245-NETWORK Contract Office 5 (36C245)

POSTED

8 days ago

DEADLINE

in 7 days

General Info

NAICS

325413 - In-Vitro Diagnostic Substance Manufacturing

Place of Performance

WA

Set-Aside

NONE

Documents

1

VA Puget Sound Healthcare - Automated Real Time PCR Platform Sources Sought

DOCX, High priority: read this first9 pages · sources-sought
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhaseClosed
Posted

Presolicitation

Type Changed

Presolicitation → Solicitation

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)
Contacts1 person available
OfficeVANCOUVER, WA, 98661, USA
Office AddressVANCOUVER, WA, 98661, USA
Contacts
Hector D GonzalezContract Specialist

Full Description

Show more
4 Puget Sound Health Care System Pathology and Laboratory Medicine Microbiology Section- Janelle Lee, Microbiology Supervisor STATEMENT OF WORK FOR AUTOMATED REAL TIME PCR PLATFORM SCOPE The VA Puget Sound Health Care System (VAPSHCS) Pathology and Laboratory Medicine Service is requesting reagents and supplies as part of a Cost Per Test Rental (CPT/CPRR). This testing is for veterans across Washington State, Oregon, Alaska and Bone Marrow and Solid Organ Transplant patients tested and monitored from across the United States. These large volume random-access molecular analyzers perform Hepatitis B (HBV) viral load, Hepatitis C (HCV) viral load, Human Immunodeficiency virus (HIV) viral load, Cytomegalovirus (CMV) viral load, Epstein-Barr virus (EBV) viral load and Human polyomavirus 1 (BK) quantitative assays. For qualitative assays, the analyzers perform sexually transmitted infection (STI) testing for Chlamydia trachomatis, Neisseria gonorrhoeae, Trichomonas vaginalis, Mycoplasma genitalium (CT/NG/TV/MG) and High-Risk Human Papillomavirus (HR HPV) as well as qualitative testing for Herpes Simplex Virus 1 and 2 (HSV-1 & HSV-2) and Varicella Zoster Virus (VZV). For upper respiratory infections, the analyzers perform SARS-CoV-2 (COVID-19) and 4-Plex testing of COVID-19, Influenza A, Influenza B and RSV. The platform uses nucleic acid (NAT) testing analysis/assays The analyzer must have minimal maintenance and allow for streamlined workload management with continuous access to reagents, samples and supplies without interrupting processing. Products numbers requested are Brand Name or Equal to Abbott Alinity m automated molecular platform. The required testing can detect and quantitate low levels of RNA or DNA, which is important in monitoring the effectiveness of therapy, to detect an infection sooner or for early diagnosis of a communicable disease. This agreement is to also include any new assays that become available on the platform. MENU/ESTIMATED VOLUME The following assays will be required to run as a single or combined NAT-based assay using a random-access analyzer on a primary or aliquoted sample tube as specified below. Testing numbers may increase by up to 5% each year. Refer to Price List for required reagents and consumables with estimated annual volume. GENERAL REQUIREMENTS The analyzer should be an automated NAT Analyzer, utilizing real time PCR technology. The vendor shall provide an analyzer with the most current version of software and hardware. The vendor shall provide the facility with Food and Drug Administration (FDA) approved analyzer/equipment, reagents, controls, calibration materials, disposables, and all consumable parts necessary for analyzer operation. Also provide electronic operating manuals, technical/service manuals, troubleshooting guide, Safety Data Sheets (SDS), preventive maintenance guide, and record logs. The vendor shall provide/install any routine and special items required to operate/maintain the equipment/analyzer in optimal condition such as but not limited to printer, UPS, and surge suppressors. The cost of these items shall be incorporated in the price proposal. EQUIPMENT FUNCTIONALITY/SALIENT CHARACTERISTICS (GENERAL) Random access for load on the go testing without the need to batch. Time to first result of less than 115 minutes. Throughput of 300 results in approximately 8 hours; up to 1080 results in 24 hours Onboard capacity of up to 20 assays at any one time Ability to run STAT samples Universal sample racks to mitigate sample sorting and batching and primary bar-coded sample tubes can be utilized On-board reagent stability of up to 30 days with no on-board refrigeration required for reagents 4 Assay Processing Units ( APUs ) on board minimizing complete instrument down time External calibration curves valid for up to 6 months; calibrators only needed for quantitative assays No daily maintenance requirements All assays run on a 24-hour time-based QC strategy Load up capacity to facilitate walk-a-way capabilities. Ability to add additional assays and newly developed assays at a later date. Systems shall be able to analyze serum, plasma, urine, emulsified swab exudates and sample aliquots. Have Bar-code capabilities for reagents, controls, calibrators, patient samples and inventory management to include data archiving and active reagent volume monitoring and warning. Shall utilize and read samples with barcode types with or without bar-code languages, with Check digits/sums. The platform shall read the following bar code types: Code 128, Code 39, Code 120, Interleaved 2 of 5, Code 93. Waste disposal of liquids output shall have onboard liquid waste containers. The analyzer must have a quality control program for all assays, which includes at a minimum: Interactive, On-board quality control (QC) package. Ability to evaluate and print QC results while the instrument is analyzing patient samples. The ability to review and print daily and monthly results. Computer print-out capability for calibrators, controls, patient results, and assay repeats. The analyzer must have positive specimen and reagent identification to reduce possible sources or error/delay and to improve laboratory efficiency. The analyzer must be able to store and retransmit results in case of interface downtime. Interfacing requirements to be provided by the vendor: Instrument HIS/LIS physical connection and translation (drivers). Shall provide bidirectional interface capability (broadcast download and host query). Any additional hardware and software needed to interface the analyzer and technical assistance with interfacing the analyzer Assays that have had FDA cleared testing methodologies assigned to them by the FDA must utilize the FDA cleared technology for the assay. If assays are FDA cleared that technology or comparable technology must be utilized by the considered platform. The ability to establish a laboratory-developed test (LDT) using the molecular instrument with lab-specific reagents and parameters must be available through LDT system capability. INSTALLATION AND VALIDATION The vendor shall provide at installation/set-up and when bringing new tests on-line, a technical support specialist who shall assist in the performance/validation studies including: installation/set-up, correlation studies (evaluation/comparison data sufficient to satisfy CAP standards), staff training, in-services to laboratory personnel and clinicians, and assist with any methodology problems and questions. This service shall be available during regular office hours on a 5 days/week basis. Throughout the life of the agreement, the vendor shall provide assistance to the user in setting up and maintaining/trouble shooting user-defined assays as additional tests are brought in-house. SERVICE AND MAINTENANCE Instrument support service shall provide assistance with troubleshooting and repair of the analyzers. On-site service shall be available Monday through Friday during regular business hours (8am-5pm). The support service shall follow-up all down time calls within 1 hour. In the event of a failure to perform the vendor agrees, with the service agreement in force, to facilitate instrument repair, if deemed necessary outside the Monday through Friday window stated in #1 above. Uptime Guarantee: Contractor shall agree that all equipment provided under the agreement shall be operable and available for use 98% of the time. Operational time is considered 8-5, M-F. Downtime shall be computed from time the contractor is notified of the incident. The vendor shall provide a twenty-four hour/seven-day service hotline with technical support. The vendor shall provide a preventative maintenance schedule to include timely scheduled vendor preventative maintenance visits as required. The vendor shall provide standard and routine software and hardware upgrades to the equipment hardware and operating systems, without additional charge (e.g. upgrades that correct or improve either the mechanical operations or software of the system and would keep the instrument performing optimally). The vendor shall define daily, weekly, monthly, and as needed maintenance and the time required to perform each maintenance task. The vendor shall indicate which tasks are user level and which are service level. Vendor required service will be scheduled in such a manner as to minimize disruptions to day-to-day operations. INSTRUMENTATION AND SOFTWARE The vendor is to conduct and complete the Medical Equipment Pre-procurement Assessment (VA Directive 6550 Appendix A) for the Office of Information Technology (OI&T) for the facility for any medical device that will be connected to the VA information network. The vendor then shall provide evidence of VACO approved remote network communication system that continuously collects and monitors performance data of the analytical systems following all the policies and procedures outlined in the VA Directive 6500, Information Security Program, and its handbooks to ensure appropriate security controls are in place. The vendor shall provide all upgrades to the equipment hardware, software, and operating systems without additional charge to the Government. Requests for upgrades or replacement, due to workload increase, excessive instrumentation/test kit failures/malfunctions, breakdowns, or service calls will be evaluated as needed/annually by the facility with communication to the vendor for modification of the contract. A high incidence of problems with any instrumentation/ test kits may indicate probable non-compliance with the terms of this contract and will entitle the facility to replacement with equipment/test kits that can produce the required criteria of this BPA satisfactorily to the user. The contractor shall remove all equipment within 90 days after notification of the expiration of the terms of this contract but not until the completion of the new vendor s equipment installation inclusive of completed cross over studies. The facility, per their protocol, will be responsible for the removal/erasing of the hard drive at analyzer removal/upgrade. If the Seattle VAMC chooses to retain the hard drive, it will be at no additional cost to the VA. The contractor and their personnel shall be subject to the same Federal laws, regulations, standards and VA policies as VA personnel, regarding information and information system security. These include, but are not limited, to Federal Information Security Management Act (FISMA), Appendix III of OMB Circular A-130, and guidance and standards, available from the Department of Commerce s National Institute of Standards and Technology (NIST). This also includes the use of common security configurations available from NIST s Web site at: http://checklists.nist.gov To ensure that appropriate security controls are in place, Contractors must follow the procedures set forth in VA Information and Information System Security/Privacy Requirements for IT Contracts located at the following Web site: http://www.iprm.oit.va.gov TRAINING The contractor shall provide an instrument training program that is coordinated with and timely to the equipment installation. This shall include training on the operation of the system, data manipulation, and basic trouble shooting and repair. Onsite training shall be provided by Contractor during the installation process for a technical representative. EVALUATION CRITERIA FOR EXISTING ON-BOARD INDIVIDUAL ASSAY REQUIREMENTS. BK Quantitative assay for BK virus must have plasma and urine as available sample types for analysis. The calibration system shall utilize not less than 2 assay calibrators to generate a calibration curve in replicates of 3 that can be stored from run to run. There must be an internal control used during extraction and detected at all levels. CMV CMV primers must be aligned with the World Health Organization (WHO) standard. The specimen requirement must be human plasma (EDTA). The assay must target sequences within the UL34 and UL80.5 genes of the CMV genome to ensure built-in assay redundancy and target regions are highly conserved. The calibration system shall utilize not less than 2 assay calibrators to generate a calibration curve in replicates of 3 that can be stored from run to run. The sensitivity of the platform must be a minimum claimed limit of detection (LOD) of 10 IU/mL and a lower limit of linearity/quantification (LLOQ) of 30 IU/mL. There must be an internal control used during extraction and detected at all levels. EBV Assay is standardized to the 1st World Health Organization (WHO) International Standard for Epstein-Barr Virus for Nucleic Acid Amplification Techniques Ability to test Cytomegalovirus (CMV) and Epstein-Barr Virus (EBV) from a single sample, which is critical for transplant patients who are at risk of developing coinfections There must be an internal control used during extraction and detected at all levels. HBV The platform selected must accurately quantify all HBV Genotypes in both plasma and serum The platform assay may not be impacted by YMDD mutants, HBsAg escape mutants, or drug-resistant mutants The calibration system shall utilize not less than a 2-point external calibration to generate a calibration curve that can be stored from run to run. Sensitivity shall be a minimum of 30 IU/mL (0.5 mL input) \Upper limit of quantification should be 1,000,000,000 IU/mL, or greater. There must be an internal control used during extraction and detected at all levels. HCV HCV assay must have confirmatory and monitoring claims for initial confirmation and diagnosis. The calibration system shall utilize not less than a 2-point external calibration to generate a calibration curve that can be stored from run to run. Platform sensitivity must not be any higher than 30 IU/mL There must be an internal control used during extraction and detected at all levels. HIV-1 HIV assay must have confirmatory and monitoring claims for initial confirmation and diagnosis. The platform specimen input must have multiple sample input volumes, which may include 1.0 mL or less. The platform subtype analysis should include Group M subtypes A-H, Group O and Group N in plasma. The platform target region must be targeted to the integrase region of the polymerase gene. The calibration system shall utilize not less than a 2-point external calibration to generate a calibration curve that can be stored from run to run. The sensitivity of the platform must be a minimum of 40 copies/mL for 1.0mL or less. There must be an internal control used during extraction and detected at all levels. The HIV-1 Assay should be 100% specific. HPV HPV assay must have primary screening indication. HPV assay must have unique evidence-based risk stratification by separately reporting HPV genotypes 16, 18 and 45. Two pools of all remaining high-risk genotypes (Group A: 31/33/52/58 and Group B: 35/39/51/56/59/66/68) in one single reaction, with each group separately reported Gynecologic samples collected using Hologic ThinPrep collection devices must be an FDA Cleared sample type. There must be an internal control used during extraction and detected at all levels, as well as a cellular control for sample quality. HSV 1&2 AND VZV HSV 1 & 2 / VZV assay provides qualitative detection and differentiation of Herpes Simplex Virus 1 (HSV-1), Herpes Simplex Virus 2 (HSV-2) and Varicella Zoster Virus (VZV) DNA from clinician-collected cutaneous or mucocutaneous lesion swab specimens. Lesion swab specimens, including cutaneous and mucocutaneous, may be collected in various commercially available viral transport media (VTM) (Copan UTM®, BD UVT, Remel M4RT®). There must be an internal control used during extraction and detected at all levels. SARS-COV-2(COVID-19), INFLUENZA A & B AND RSV COVID-19 may be acquired alone as a single assay, with corresponding assay-specific reagents. Respiratory 4-plex for COVID-19, Influenza A, Influenza B and RSV assay has ability to mask and unmask results based on the analytes ordered. Results not initially ordered can be recalled and resulted within 14 days of testing specific to the patient without recalling the sample or the patient. There must be an internal control used during extraction and detected at all levels. STI Must have FDA Cleared 4-in-1 STI testing for CT/NG/TV/MG, enabling up to 4 results in a single analysis. The sample collection system must utilize a single collection device for all FDA Cleared sample types and be approved for urine, throat, vaginal, rectal collection sites. Gynecologic samples collected using Hologic ThinPrep collection devices must be an FDA Cleared sample type. There must be an internal control used during extraction and detected at all levels, as well as a cellular control for sample quality. STI-4-Plex assay has ability to mask and unmask results based on the analytes ordered Results not initially ordered can be recalled and resulted within 14 days of testing specific to the patient without recalling the sample or the patient. Testing must remain compatible with the current laboratory developed test (LDT) held by Seattle VA Puget Sound Healthcare System. This LDT is for self-collected throat and rectal swab samples in a clinical or non-clinical setting. Requirements are as follows: that the Abbott Alinity m multi-Collect specimen collection kit is used, that the Abbott Alinity m instrument is used, that the Alinity m STI CTRL and STI AMP kits are used with accompanying Alinity m consumables and that testing must occur within the Molecular section of the Microbiology Laboratory at Seattle VA Puget Sound. SUPPLIES REQUIRED TO MEET AGENCY S NEEDS Brand name or equal reagents and supplies are required for continuation of patient care. The Seattle VA Puget Sound Medical Center laboratory requires the procurement of reagents, supplies and instrumentation to continue to provide the following infectious disease molecular assays: Hepatitis B (HBV) viral load, Hepatitis C (HCV) viral load, Human Immunodeficiency virus (HIV) viral load, Cytomegalovirus (CMV) viral load, Epstein-Barr virus (EBV) viral load and Human polyomavirus 1 (BK) quantitative assays. For qualitative assays, the analyzers perform sexually transmitted infection (STI) testing for Chlamydia trachomatis, Neisseria gonorrhoeae, Trichomonas vaginalis, Mycoplasma genitalium (CT/NG/TV/MG) and High-Risk Human Papillomavirus (HR HPV) as well as qualitative testing for Herpes Simplex Virus 1 and 2 (HSV-1 & HSV-2) and Varicella Zoster Virus (VZV). For upper respiratory infections, the analyzers perform SARS-CoV-2 (COVID-19) and 4-Plex testing of COVID-19, Influenza A, Influenza B and RSV. The following reagents and supplies are required for these assays. Product Description Product Description Alinity m HIV-1 CAL Kit Alinity m EBV CAL Kit Alinity m HIV-1 CTRL Kit Alinity m EBV CTRL Kit Alinity m HIV-1 AMP Kit Alinity m EBV AMP Kit Alinity m HBV CAL Kit Alinity m CMV CAL Kit Alinity m HBV CTRL Kit Alinity m CMV CTRL Kit Alinity m HBV AMP Kit Alinity m CMV AMP Kit Alinity m HCV CAL Kit Alinity m LRV Tube Alinity m HCV CTRL Kit Alinity m Transport Tube Pierceable Capped Alinity m HCV AMP Kit Alinity m Transport Tube Alinity m Sample Prep Kit2 Alinity m Pierceable Cap Alinity m HR HPV CTRL Kit Alinity m Aliquot Tube Alinity m HR HPV AMP Kit US Alinity m Specimen Dilution Kit 1 Alinity m STI CTRL Kit Alinity m HSV 1 & 2 / VZV CTRL Kit Alinity m STI AMP Kit Alinity m HSV 1 & 2 / VZV AMP Kit Alinity m Sample Prep Kit 1 Abbott Universal Collection Kit Alinity m multi-Collect Specimen Collection Kit Alinity m SARS-CoV-2 CTRLKit Alinity m Lysis Solution SARS-CoV-2 CTRLKIT - 510k Alinity m Ethanol Solution Alinity m SARS-CoV-2 AMP Kit Alinity m Diluent Solution SARS-CoV-2 AMPKIT - 510k Alinity m Vapor Barrier Solution Alinity m Resp-4-Plex CTRL Kit - 510k Alinity m Bottle for Ethanol Use Alinity m Resp-4-Plex CTRL Kit Alinity m Pipette Tips, 50uL Alinity m Resp-4-Plex AMPKit - 510k Alinity m Pipette Tips, 1000uL Alinity m Resp-4-Plex AMPKit Alinity m Integrated Reaction Units (IRU) Alinity m Urine Transport Kit Alinity m Waste Box Alinity m BKV CAL Alinity m Handheld Barcode Scanner Alinity m BKV CTRL Alinity m Universal Sample Rack Alinity m BKV AMP Kit Alinity m Sample Rack Holder Universal Collection Kit - 510k Alinity m IRU Waste Container Alinity m Simpli Collect Urine & Swab kits Period of Performance Base Year: 12/1/2025 to 11/30/2026 Option Year One: 12/1/2026 to 11/30/2027 Option Year Two: 12/1/2027 to 11/30/2028 Option Year Three: 12/1/2028 to 11/30/2029 Option Year Four: 12/1/2029 to 11/30/2030

More opportunities from Department Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)

Same awarding agency

NAICS: 238220
New
Federal
J041--White City B249 SE HVAC Repair
Solicitation # 36C26027Q0102
Solicitation 36C26027Q0102 is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) issued by the Department of Veterans Affairs. The contract requires the repair of a Mitsubishi R-410A comfort-cooling system (Serial 07W0090) located on the southeast side of Building B249 at the VA Southern Oregon Rehabilitation Center and Clinics in White City, Oregon. The scope of work includes leak detection, brazing repairs with nitrogen purge, refrigerant recovery, evacuation to less than 500 microns, and recharging the system to nameplate requirements. The contractor must provide a detailed service report documenting the root cause, repair actions, and compliance with EPA Section 608 and VHA ICRA/PCRA controls for occupied healthcare facilities. The period of performance is 30 calendar days from the Notice to Proceed. Award will be granted to the responsible offeror whose proposal is most advantageous to the government, considering price and other specified factors. Key regulatory requirements include adherence to OSHA 29 CFR 1910.147 for lockout/tagout and 29 CFR 1910.333 for electrical safety. Payments will be processed via Electronic Funds Transfer, and invoices must be submitted electronically through the Tungsten Network. Offerors must provide their Unique Entity Identifier and maintain firm pricing for 60 calendar days from the response deadline of November 10, 2026.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

1 day ago

DEADLINE

in 12 days
View Details
NAICS: 334513
New
Federal
Boiler Plant O2 Sensor Replacement
Solicitation # 36C26027Q0101
The Department of Veterans Affairs, through the Network Contract Office 20, is conducting market research via a Sources Sought Notice for a firm-fixed price service contract to perform inspection, testing, maintenance, and repair of three model 6888 Rosemount flue gas analyzers. The work will be performed at the VA Southern Oregon Rehabilitation Center and Clinics in White City, Oregon. The primary scope involves replacing internal O2 analyzer components using original equipment manufacturer parts, specifically 18 inch standard cells, 18 inch heater strut assemblies, Hastelloy with Vee Deflectors for service up to 1300 degrees Fahrenheit, and new flange gaskets. The period of performance is six months, with on-site work required during core hours of 7:00 AM to 4:00 PM, Monday through Friday. This opportunity is designated as a total Small Business Set Aside under NAICS code 334513, with a size standard of no more than 750 employees. Qualified sources, including SDVOSB and VOSB entities, must provide company details, SAM.gov UEI numbers, and proof of manufacturer authorization if they are not the OEM. Contractors must employ qualified personnel, maintain general third-party liability insurance per FAR 52.228-5, and adhere to NEC, OSHA, and JCAHO standards. Deliverables include written daily reports to the Deputy Chief Facilities Management and testing documentation provided to the Contracting Officer's Representative. Interested parties are requested to provide a courtesy quote and capability statement to assist the government in evaluating price reasonableness and market availability.
Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables

POSTED

3 days ago

DEADLINE

in 5 days
View Details
NAICS: 325998
New
Federal
Microbiological media purchase order for Clinical Microbiology laboratory.
Solicitation # 36C26027Q0104
The Department of Veterans Affairs Network Contracting Office 20 is seeking sources for a microbiology testing media purchase order to support the Seattle Division of the VA Puget Sound Medical Center. This requirement covers a wide range of critical supplies for identifying pathogenic organisms in veteran patients, including long shelf-life products like Oxidase and Indole, perishable selective agar, biochemical test kits, and ATCC organisms mandated by the College of American Pathologists for quality control. The contract is structured with a base year running from February 1, 2027, to January 31, 2028, followed by four subsequent one-year option periods ending January 31, 2032. Deliveries are to be made to the Microbiology Lab in Seattle, with weekly shipments typically scheduled for Tuesdays and individual requests fulfilled as available. Due to the perishable nature of many items, the vendor must provide tracking information, and the cost of next-day delivery for all perishable goods must be included in the individual item price. All temperature-liable products require immediate refrigeration upon delivery. Invoicing is processed through the Austin Automated Payment System in Texas, and the vendor must provide SDS sheets for all media upon request. This sources-sought notice specifically looks for capable sources, including qualified SDVOSB/VOSB entities, with a response deadline of November 10, 2026.
All Other Miscellaneous Chemical Product and Preparation Manufacturing

POSTED

3 days ago

DEADLINE

in 12 days
View Details
NAICS: 238220
New
Federal
Z1DA--CON-NRM-668-22-106 Correct Domestic Water System
Solicitation # 36C26027R0014
Solicitation 36C26027R0014 is a negotiated request for proposals for the Department of Veterans Affairs to correct domestic water system deficiencies in Buildings 1 and 12 at the Mann-Grandstaff VA Medical Center in Spokane, Washington. The project is 100% set aside for Service-Disabled Veteran-Owned Small Businesses under NAICS 238220, with an estimated contract magnitude between $1 million and $2 million. The primary objective is to modify hot and cold potable water distribution systems to comply with VHA Directive 1061 for the prevention of scald injuries and Health Care-Associated Legionella Disease. The scope includes all labor, materials, and equipment, with a specific requirement to flush potable water dispensing fixtures twice weekly from installation until final acceptance. The period of performance is 275 calendar days from the Notice to Proceed. The government will utilize a Best Value tradeoff process for award, prioritizing technical experience and past performance over cost. Technical evaluations will favor offerors with demonstrated experience in phasing and Infection Control Risk Assessment (ICRA) within 24-hour operational emergency rooms. Proposals must be submitted in three separate volumes—Technical, Past Performance, and Price—by November 23, 2026. Awardees must provide performance and payment bonds, adhere to Davis-Bacon Act wage determinations, and comply with Buy American requirements. Additionally, the contractor must maintain strict confidentiality regarding sensitive information and provide a one-year warranty on all materials and installation.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

3 days ago

DEADLINE

in about 1 month
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS