Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity was posted on March 9, 2018. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

71--Replacement Beds (VA-18-902581)

Awarded
36C26018Q0169Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

This contract concerns the procurement of replacement beds for various medical units, including Med Surg, SDU, and CLC buildings. The requirements specify a patient weight capacity of 500 lbs and a bed frame designed to remain stationary when adjusting positions to prevent equipment displacement or patient injury. Essential features include a full single post trapeze system with locking side positions and staff controls located on both the side rails and the footboard to ensure accessibility. The procurement emphasizes continuity with existing Stryker equipment to streamline staff training and maintenance. Required mattress specifications include a therapeutic gel surface rather than foam to reduce pressure ulcers, with a specialized breathable cover for pressure redistribution and microclimate management. Warranty requirements are strict, necessitating a 10 year warranty on the mattress core and a 3 year warranty on the cover. Certain optional features, such as USB ports, motion-activated nightlights, and integrated blower air surfaces, are not required or are explicitly declined in favor of versatile gel/foam options.

General Info

Agency

N/A

Contract Value

$531,060.2

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

MI, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

2 updates
PhaseAwarded
Posted

Presolicitation

Type Changed

Presolicitation → Solicitation

Notice updated

Notice type changed from Solicitation to Special Notice. The response deadline was removed. The notice title changed. Set-aside removed. The notice description changed.

Notice updated

Response deadline added: Mar 9, 2018. The notice description changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
ContactsNo contacts available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Answers to technical questions: Q. Regarding CLIN 0001, the bed we have to offer, LINET s Eleganza 3, comes with a straight power cord (not coiled). Is coiled a requirement? A. No Q. The LINET mattress includes a cover. Is CLIN 0003 a special cover or an extra cover? A. It is a special cover that equalizes pressure redistribution while balancing the Micro climate of the skin through it highly breathable fabric. Q. Weight capacity of 500lbs. -Please clarify if this is patient weight or safe working load. Patient Weight Q. Stay-put retractable bed from to avoid bed movement when changing settings and avoids bed sliding on floor damaging cords, drain tubes etc. or injury to staff members. - Please describe the purpose of this function- 1) to shorten (retraction) and to lengthen (extension) of the bed deck for patient height adjustments: and/or 2) for the bed deck to adjust and maintain patient position in bed with changes in the elevation of the head section. A. This is to avoid the bed frame/wheels from moving when changing the frame position like to a sitting up position. Incident when this happened on a different brand and pinched an 02 tubing flow to patient. Q. Must include full single post trapeze system that turns and locks to either side as well as over bed for ease of patient assist movements and use of ceiling lift. -Is a fixed single post with movable trapeze system acceptable A. No, needs to have locking positions to the side without having to remove the post ensuring a stay in position when using ceiling lift or giving cares. Q. Staff controls on both side rails and footboard. Is it acceptable to have caregiver controls on both side rails and caregiver graphical control interface on the side rail that is touchscreen, instead of staff controls on the footboard? A. No, because with bedside table, iv poles, etc. blocking access at times to controls on side rails. Especially during procedures and meal times. Q. 3 mode Bed exit alarm system. Is a tone or verbal prompt in multiple languages required/preferred? A. No Is an alarm auto reset required? A. No Q. Is powered (push of a button) or manual extension required? A. Currently use manual method with foot extender and pad. Push button would only work on air mattresses or you would still have to add cushion/pad if frame auto extended. Q. Is a USB Port required? A.No Q. Is a motion activated nightlight required? A. No Q. Is a patient pendant required? A. No Q. Is it acceptable to provide a Powered Air Surface that includes integrated Blower (no blower box at foot-end of bed), Comfort Controls, Turn Assist and Focused Microclimate® Management to help manage pressure, shear and moisture to deliver optimal wound prevention and healing, instead of a gel/foam convertible mattress? A. No. We use these beds on multiple degree of care units and areas such as our Med Surge Unit, air mattresses hinder and do not support independent patients exit and entry especially with post-op ortho surgeries. We need to have the option to switch from the gel/foam to powered air surface depending on individual patient needs. Q. Is turn assist required? A. No-air mattress surface not wanted for this request Q. Are comfort controls required? A. No Q. Is a blower box required for every mattress? A. No Q. Is it acceptable to provide a 1 year mattress warranty, since 10 years is not the industry standard? A. No, that would not be cost effective and replace date for frames is 10-15 years. Q. Will you please consider Brand Name or Equal for Salient Characteristics, the reason I ask is because the solicitation language is steered towards Stryker A. This is because the rest of our beds no due for replacement are Stryker s with the isoflex mattresses in our Med Surg, SDU & CLC buildings.. This is to support continuity regarding mattress surfaces, staff training and Bio Med trained staff for annual PM s and repair.) Q. Is the 10 year warranty requested on both the core and cover? A. Core is 10 years and cover is 3 years Q. Would you consider an equivalent therapeutic mattress with foam an acceptable equivalent (some think superior) to the therapeutic mattress with gel? A. No. We actually purchased Isoflex mattresses with the therapeutic gel to remove the foam equivalent and have had a significant decrease in hospital acquired pressure ulcers. We also trialed both types and our wound care team completed extensive mapping of the surfaces using varied patient weights.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS