Aboveground Fuel Storage Repair

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of Defense → Navfacsyscom Far EastView Agency

NAICS

237120 - Oil and Gas Pipeline and Related Structures ConstructionView NAICS

Place of Performance

AP

Set-Aside

NONE

Documents

This scope was carved out of N4008426Q7502.

The full solicitation package (7 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

Solicitation N4008426Q7502DBB UFC Repair Aboveground Fuel Storage, ABAB, Palawan, Philippines

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Navfacsyscom Far East
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of Defense → Navfacsyscom Far East
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Repair and rehabilitation of existing aboveground fuel storage tanks and associated infrastructure at Antonio Bautista Air Base.

Similar Contracts

Same NAICS industry code

NAICS: 237120
New
SLED
Atascadero Creek Lake Fill Pipeline Repair ProjectThe City of Atascadero is undertaking the Atascadero Creek Lake Fill Pipeline Repair Project to address the degradation of approximately 350 linear feet of pipeline that transports water from Atascadero Creek to Atascadero Lake during high-flow events. The project involves replacing the damaged pipeline segment with an equivalent capacity pipe installed in the same alignment, along with repairing associated concrete hold-downs and maintaining existing intake structures and diversion boxes. Approximately 96 cubic yards of excavation will be required to remove the old pipeline and clear riparian vegetation adjacent to and above the pipeline. The work is located in Atascadero, California, with a NAICS code of 237120 for sewer line and related utility construction. The project is posted as a forecast on July 2, 2026, with no solicitation number or estimated contract value provided. Environmental compliance and pollution control are central to the project’s execution. All construction personnel must undergo training conducted by a qualified biologist covering special-status species, protection measures under discretionary permits, and the implications of violating the Federal and California Endangered Species Acts. A sign-in sheet and training fact sheet must be maintained and distributed. Construction activities must adhere to strict erosion and sediment control requirements, including daily maintenance of silt fences and fiber rolls, implemented according to approved design and operational standards. All fueling, equipment maintenance, and staging areas must be located at least 50 feet from any water body, and an on-site spill plan with oil absorbent pads must be available. Fugitive dust must be monitored to ensure emissions remain under 20% opacity, with designated personnel reporting to the APCD Compliance Division, and no idling of diesel equipment is permitted. Upon completion, all disturbed areas must be restored to pre-project contours, and all equipment, materials, and temporary best management practices must be removed from the site. Supporting documentation includes site photographs, species data, and a mitigation summary table to support environmental permitting and compliance.
City of Atascadero

POSTED

about 20 hours ago

DEADLINE

N/A
View Details
NAICS: 237120
New
Federal
Repair Natural Gas Phase 1 and Phase 2 Base Wide, Vance AFB, OK
Solicitation # XTLF-21-1031
This solicitation, identified as XTLF-21-1031, is a combined synopsis and solicitation for commercial services under FAR 12.6 and FAR Part 13, requesting firm-fixed-price proposals to repair natural gas infrastructure across Phase 1 and Phase 2 at Vance Air Force Base in Enid, Oklahoma. The total estimated contract value ranges from $1,000,000 to $5,000,000, with funds not currently available and no award to be made until federal funding is secured. The Government retains the right to cancel the solicitation at any time without obligation to reimburse offerors for costs incurred. Proposals must be submitted electronically to Betty Kliewer by August 25, 2026, at 11:00 AM CST, and must remain valid for 180 days after the closing date. Award will be made on a Low Price/Technically Acceptable basis, requiring offerors to submit completed Bid Forms PA, PB, and Combine, along with detailed technical specifications, a line-item labor and material cost breakdown, and qualifications demonstrating relevant experience, certifications, and capability. All contractors must have an active, non-expired registration in the System for Award Management (SAM) to be eligible. A mandatory site visit is scheduled for July 28, 2026, at 10:00 AM CST, with attendees required to report to the Visitor Center at Building F72 at least 45 to 60 minutes prior, present valid government-recognized identification (REAL ID or U.S. Passport), and provide proof of vehicle registration and insurance to gain base access. All attendees must adhere to Vance AFB entry and conduct regulations. The contractor is responsible for furnishing all personnel, equipment, materials, and services per the attached Repair Natural Gas Specifications, which incorporate compliance with ASTM, ASME, API, OSHA, EPA, and MIL-STD-101 standards. Requirements include proper identification marking of aboveground and buried piping per color-coded and legend standards, use of brass tags for small-diameter lines, and yellow warning tape for buried lines. The contractor must maintain a qualified Project Superintendent and Site Safety and Health Officer on-site at all times, with alternates available, and ensure adherence to EM 385-1-1 safety protocols, Buy American Act compliance, permit acquisition for hazardous activities, and submission of comprehensive deliverables including as-built drawings,
FA3029 71 Ftw Cvc

POSTED

3 days ago

DEADLINE

in 6 days
View Details

More opportunities from Department Of Defense → Navfacsyscom Far East

Same awarding agency

NAICS: 238220
New
Federal
INSTALL A/C UNIT, HAZARDOUS STORAGE FOR LABORATORY, DFSP HACHINOHE, JAPAN
Solicitation # N4008426Q7009
The contractor is required to furnish all labor, materials, equipment, transportation, supervision, and engineering necessary to install an air conditioning unit and hazardous storage facility at the DFSP Hachinohe laboratory in Japan under eProject No. 1835502, with performance beginning within 15 calendar days after award and concluding by April 13, 2027, spanning a total of 270 calendar days. The procurement is conducted as a Firm Fixed Price sealed bid under FAR 52.236-21, 52.236-5, 52.236-6, and other construction-specific clauses, all modified by Deviation 2026-O0038, and must comply strictly with NAVFAC drawings numbered 17356087 through 17356090 and the Statement of Work. The award will be made on a Lowest Price Technically Acceptable basis, with technical acceptability determined by mandatory compliance with requirements including a valid Japanese construction business license, authorization to operate legally in Japan, adherence to Japanese labor laws, a Japanese bank account for payment via DFAS Japan, current SAM registration, a Unique Entity Identifier, a CAGE code, and at least CMMC Level 1 self-assessed status. Offerors must submit a Site Visit Log by July 28, 2026, listing all attendees of the mandatory pre-quote conference and site visit scheduled for August 4, 2026, at NAVFAC FE in Misawa Air Base followed by DFSP Hachinohe, with unescorted access requiring prior coordination and temporary base passes. All submissions must be electronically filed through the PIEE portal by August 24, 2026, at 11:00 AM JST, in English, with pricing quoted in Japanese Yen and excluding Japanese Consumption Tax. Invoicing must be submitted via WAWF using approved document types, with payment processed through HQ0721, and acceptance occurs at Naval Air Facility Misawa under the authority of ROICC Atsugi Detail Misawa. Contractors must also comply with security protocols including antiterrorism awareness training, safeguarding covered defense information, prohibition on acquiring prohibited telecommunications equipment, and disclosure requirements for covered defense telecommunications services, while U.S. nationals must register with the U.S. Embassy in Japan. The contracting officer will evaluate only for responsiveness and responsibility
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

4 days ago

DEADLINE

in 4 days
View Details