Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, July 22 at 2:00 PM EDT

Register Free →

This Solicitation opportunity from Government of Canada was posted on September 30, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Aethalometer- Supply Arrangement (SA) E60PV-19EQUI

Closed
5000088813Canada

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Government of Canada → Department of the Environment (ECCC )View Agency

NAICS

N/A

Place of Performance

*Canada, CAN

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyGovernment of Canada → Department of the Environment (ECCC )
Contacts1 person available
OfficeN/A
Organization / Agency
Government of Canada → Department of the Environment (ECCC )
View Agency Profile
Office AddressN/A
Contacts
Mitchell PalmerPoint of Contact

Full Description

Show more
Environment and Climate Change Canada has a requirement for an aethalometer to measure BC and BrC absorption for laboratory and field studies. Mandatory Technical Criteria: The following requirements are the mandatory technical evaluation criteria which will be evaluated during the Bid Evaluation. In addition, the Contractor will be required to meet all of the mandatory technical requirements for the duration of the Contract. Bidders are requested to cross reference the mandatory technical criteria in a concise format by using page, paragraph(s) & sub-paragraphs as applicable to their supporting technical documentation. Item Criteria Reference to substantiation in the Technical Bid M1 Must include a field deployable aethalometer to measure aerosol absorption at multiple wavelengths (from the ultraviolet to the near-infrared) simultaneously. M2 Must be able to provide continuous data for eliminating the filter loading effect M3 Must include an inlet cyclone/impactor for measuring aerosol absorption in PM1 and PM2.5 M4 Must include a dryer with a pump for continuously conditioning the sample flow M5 Must include a calibration kit to validate the optical performance of the instrument M6 Must have USB ports, digital data ports, and Ethernet for data transfer M7 Must be able to measure aerosol absorption at 9 different wavelengths or more between 340 nm and 950 nm simultaneously. M8 Must be able to measure aerosol absorption at 3 different wavelengths or more between 340 nm and 450 nm simultaneously for BrC characterization M9 Must be able to provide aerosol absorption measurement at 5 years of 1-minute resolution data.