This Solicitation opportunity from Government of Canada was posted on September 30, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
Aethalometer- Supply Arrangement (SA) E60PV-19EQUI
Closed
5000088813CanadaSubmission Closed
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
General Info
Agency
Government of Canada → Department of the Environment (ECCC )View Agency
NAICS
N/A
Place of Performance
*Canada, CANSet-Aside
NONE
Documents
(0)AI Contract Breakdown
Uniform Contract FormatNo contract breakdown available.
Cannot generate Contract Breakdown because no documents were found from this contract's source.
Timeline
PhaseClosed
Submission Closed
Organization & Contact Information
Show more
AgencyGovernment of Canada → Department of the Environment (ECCC )
Contacts1 person available
OfficeN/A
Organization / Agency
Government of Canada → Department of the Environment (ECCC )
View Agency ProfileOffice AddressN/A
Contacts
Full Description
Show more
Environment and Climate Change Canada has a requirement for an aethalometer to measure BC and BrC absorption for laboratory and field studies.
Mandatory Technical Criteria:
The following requirements are the mandatory technical evaluation criteria which will be evaluated during the Bid Evaluation. In addition, the Contractor will be required to meet all of the mandatory technical requirements for the duration of the Contract. Bidders are requested to cross reference the mandatory technical criteria in a concise format by using page, paragraph(s) & sub-paragraphs as applicable to their supporting technical documentation.
Item Criteria Reference to substantiation in the Technical Bid
M1 Must include a field deployable aethalometer to measure aerosol absorption at multiple wavelengths (from the ultraviolet to the near-infrared) simultaneously.
M2 Must be able to provide continuous data for eliminating the filter loading effect
M3 Must include an inlet cyclone/impactor for measuring aerosol absorption in PM1 and PM2.5
M4 Must include a dryer with a pump for continuously conditioning the sample flow
M5 Must include a calibration kit to validate the optical performance of the instrument
M6 Must have USB ports, digital data ports, and Ethernet for data transfer
M7 Must be able to measure aerosol absorption at 9 different wavelengths or more between 340 nm and 950 nm simultaneously.
M8 Must be able to measure aerosol absorption at 3 different wavelengths or more between 340 nm and 450 nm simultaneously for BrC characterization
M9 Must be able to provide aerosol absorption measurement at 5 years of 1-minute resolution data.