AN/TSQ-216 Environmental Control Unit (ECU) Replacement

Active
N66001_SNOTE_000682A6Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Space and Naval Warfare Systems Center Pacific (SSC Pacific) is seeking information for the potential replacement of the AN/TSQ-216 Environmental Control Unit (ECU), which provides heating and cooling functions for the Remote Landing Site Tower (RLST). The RLST is a deployable air traffic control system used at forward operating bases and other austere locations, operating off either portable generators or vehicle power supplies. This request is a Request for Information (RFI) aimed purely at gathering industry feedback and market research to assist in planning; it is not a solicitation for proposals, nor does it guarantee a future contract. Respondents should be aware that costs incurred in responding will not be reimbursed, and not responding will not prevent future participation should an RFP be issued. Respondents are invited to submit a white paper of up to ten pages in a specified format, addressing their company capabilities, experience, rough order of magnitude cost and schedule estimates for delivering a replacement ECU, and any technical or contractual feedback regarding the requirements. The replacement ECU must meet size and weight constraints to fit within the RLST transport configuration and function in the existing power environments. The RFI includes detailed specifications and environmental considerations based on the harsh conditions experienced at locations like Yuma, Arizona. White papers must be submitted electronically by January 30, 2013, and may include proprietary information clearly marked for government safeguarding. SSC Pacific may follow up for clarification but is not obligated to engage further.

General Info

SSC Pacific requests industry input for replacement ECU for deployable RLST, no contract guaranteed.

NAICS

333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

Place of Performance

CA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

special-notice

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Niwc Pacific
ContactsNo contacts available
OfficeSAN DIEGO, CA, 92152-5001, USA
Office AddressSAN DIEGO, CA, 92152-5001, USA
ContactsNo contact information available

Full Description

Show more
1. Introduction 1.1. Space and Naval Warfare Systems Center Pacfic (SSC Pacific) is seeking information regarding the replacement of the . AN/TSQ-216 Environmental Control Unit (ECU) 1.2. THIS IS A REQUEST FOR INFORMATION (RFI) ONLY. This RFI is issued solely for information and planning purposes it does not constitute a Request for Proposal (RFP) or a promise to issue an RFP in the future. This request for information does not commit the government to contract for any supply or service. Further, at this time, the Navy is not seeking proposals and will not accept unsolicited proposals. Respondents are advised that the U.S. Government will not pay for any information or administrative costs incurred in response to this RFI; all costs associated with responding to this RFI will be solely at the interested partys expense. Not responding to this RFI does not preclude participation in any future RFP, if issued. If a solicitation is released, it will be synopsized on the Federal Business Opportunities (FedBizOpps) website (http://www.fbo.gov). It is the responsibility of the potential offerors to monitor that web site for additional information pertaining to this RFI or a requirement that may relate to this RFI. 2. Background 2.1. The Navy is contemplating a replacement Environmental Control Unit (ECU) for the AN/TSQ-216 Remote Landing Site Tower (RLST). The RLST is a world-wide deployable asset that provides Visual Flight Rules (VFR) control of military aircraft at Forward Operating Bases, Forward Air Refueling and Rearming Points and other such rudimentary landing zones. The RLST consists of a portable air traffic control operations shelter that sits in the back of a HMMWV and a trailer that carries's communications and power generating equipment. The RLST is self contained in that its power is provided either by portable generators that are part of the system or the 24 VDC of the HMMWV and the ECU must function in either power environment. The ECU provides heating and cooling functions for the RLST in all weather conditions and is currently mounted on the roof of the operations shelter. 2.2. The specifications for the ECU are attached and the replacement system must be able to fit within the confines of the RLST while it is in transportation mode. The ECU does not have to be roof mounted if a solution is available that meets size and weight restrictions contained in the specification sheet. An additional information sheet is provided to assist in calculating heat loads for the windows in the RLST using a lat/long location of Yuma, Arizona. Yuma is the hottest garrison location of the AN/TSQ-216 RLST. 3. Responses: 3.1. Interested parties are requested to respond to this RFI with a white paper not to exceed 10 pages. White papers shall be submitted in Microsoft Word .doc or .docx formats, Times New Roman 11-point or 12-point font, with 1-inch margins, minimum, all around. Figures, schematics, drawings, diagrams and tables may be in a smaller type size, but shall be no smaller than 8-point. All narrative text must be single-spaced. Figures, schematics, drawings, diagrams, schedule charts, and tables may also be single-spaced. 3.2. White Paper Responses containing data or information not to be disclosed to the public for any purpose or used by the Government except for market research shall include statements to that effect on the first/title page and on each page that contains such data or information. Respondents bear sole responsibility for clearly marking said information as such to ensure appropriate safeguarding by the Government. The Government shall not be held liable for any damages incurred if proprietary information is not properly identified. To aid the Government, sources are requested to segregate proprietary information. Please be advised that all submissions become Government property and will not be returned. 3.3. White Paper Responses should be prepared IAW format specified in 3.1 and should simply and economically provide a straightforward, concise delineation of respondent's capabilities and an approach needed to replace the ECU as described in this RFI. White Paper Responses should address the following: 3.3.1. A company description and discussion of company capabilities with respect to fulfilling the objectives outlined in this RFI. Please include your business type/size for NAICS 333415. 3.3.2. A description of previous experience in this field with either commercial or government customers. 3.3.3. A rough order of magnitude (ROM) estimate for cost and schedule to deliver one ECU. The ROM should, to the extent practicable, delineate non-recurring engineering (NRE). 3.3.4. Any additional information that will assist in understanding your responses to the RFI. 3.3.5. Respondents are encouraged to provide comment with respect to the following: 3.3.5.1. Technical aspects described herein that are either too vague or overly-burdensome and the reason(s) for commenting on those aspects; 3.3.5.2. Technical or contractual aspects that you feel that the government should consider before formally soliciting proposals for systems conceptually outlined in this RFI; 3.4. All questions regarding this RFI shall be submitted via email to contact@example.gov. 3.5. White Paper Responses are due no later than 30 January 2013, 1400pm PST, and shall be delivered to Richard Hammersmith via email at contact@example.gov. 3.6. Industry Response / Clarifications: SSC Pacific Contracts representatives may or may not choose to contact potential offerors. Such communications would only be intended to gain further clarification or written responses to questions from technical end-users.

Similar Contracts

Same NAICS industry code

More opportunities from Department Of Defense → Niwc Pacific

Same awarding agency

NAICS: 236220
New
Federal
General Construction Job Order Contract (JOC)
Solicitation # N6600127R0059
NIWC Pacific is competitively soliciting a single-award, indefinite-delivery, indefinite-quantity Job Order Contract (JOC) set aside for participants in the SBA 8(a) Business Development Program. Under NAICS 236220, the contract provides general construction services, including minor new construction, maintenance, repair, rehabilitation, alteration, and renovation of real property. The scope of work encompasses electrical, mechanical, HVAC, fire suppression, structural repair, roofing, paving, interior finishes, and engineering design. Performance will take place within the NIWC Pacific area of responsibility, specifically focusing on the San Diego metropolitan area, including Naval Base Point Loma and Naval Base San Diego. The contract features a 24-month base period with one 36-month option period, for a potential total duration of 60 months. Work is executed through firm-fixed-price task orders priced using predetermined unit prices and the awardee's proposed bid price coefficient, with pricing based on R.S. MEANS cost software. Key requirements include the provision of a Site Safety and Health Officer, adherence to Unified Facilities Guide Specifications and international building and fire codes, and the management of Controlled Unclassified Information. Task order awards are based on technical understanding, efficiency of the work plan, rationale for labor and materials, and sustainable design features.
Commercial and Institutional Building Construction

POSTED

1 day ago

DEADLINE

in 6 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS