Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on November 18, 2008. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Annual & Quarterly Preventive Maintenance on Sprinkler Systems

Closed
ANCDF-RFQ-WA9-0190Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 922160
SLED
2026 Volunteer Fire Capacity Grant
Solicitation # 2139681
The New York State Department of Environmental Conservation is administering the 2026 Volunteer Fire Capacity Grant Program, funded by a federal appropriation of 857,629 dollars. This program provides matching grants to eligible rural fire departments for the purchase of wildland firefighting suppression supplies. To be eligible, departments must be comprised of at least 80 percent volunteer personnel and serve a rural area, defined as a town or village with a population of 10,000 or less based on the 2020 Census. Selected departments can receive a maximum award of 3,500 dollars, which must be matched 50/50 by the recipient. Grant funds must be used for items directly related to wildland firefighting that benefit the local rural community, with a restriction that no individual item exceeds 9,999 dollars. Selection is based on the department's funding history over the previous five years, whether it is a newly formed establishment, and the presence of a Native American community within its jurisdiction. The program operates under federal guidelines from the US Forest Service and the Cooperative Forestry Assistance Act of 1978. Applications are accepted through December 30, 2026. This solicitation does not have specific goals for Service-Disabled Veteran-Owned, Minority, Women, or Disadvantaged Business Enterprises. All inquiries and applications are managed by the Volunteer Fire Capacity Grant Coordinator within the Division of Forest Protection.
NYS Department of Environmental Conservation

POSTED

8 days ago

DEADLINE

in 2 months

General Info

NAICS

922160 - Fire Protection

Place of Performance

3580 Morrisville Rd, ANNISTON, AL, 36201, USA

Set-Aside

NONE

Documents

1

RFQ ANCDF-RFQ-WA9-0190: APM and QPM on Sprinkler Systems

PDF, High priority: read this firstrfq
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W4MM USA Joint Munitions Command
Contacts1 person available
OfficeANNISTON, AL, 36201-5000, USA
Office AddressANNISTON, AL, 36201-5000, USA
Contacts
Ashley M Rollins

Full Description

Show more
WA9-0190 All parts, materials and tools will be provided by the contractor. Contractor(s) will participate in the Pre-Job Briefings to insure that good communications is established with WANCDF Engineering, Operations and Maintenance departments before any work begins. Extreme caution shall be taken to insure that unplanned outages will not occur. Westinghouse Anniston (WA) is soliciting the services of a Field Service Technician (Prefer Certified Fire Protection Company) to perform quarterly and Annual inspection, testing and certification of the PMB, CHB and CHB UPA sprinkler systems. All inspection and testing shall be in accordance with NFPA 72 and 25. An electrical technician will be present in order to escort and assist the vendor with PM as needed. Testing and inspection shall be performed in accordance with NFPA 25 QUARTERLY: 4 performances per system, per fiscal year of the following: Work should include, but is not limited to the following: 1. Inspect all threaded and rubber gasket type fittings for damage, evidence of leakage, corrosion, or erosion. 2. Inspect all gauges to verify that they are in their proper operating range, no leaks are present, and there is no physical damage. 3. Perform a walk down of the entire sprinkler system inspecting for painted sprinkler heads, obstructed sprinkler heads, or leaks. 4. Visually inspect the sprinkler system hangers and clamps for damaged , missing, or loose supports or clamps. 5. Perform a main drain test. Compare readings with previous test to determine whether there has been a change in the water supply piping or control valves. 6. Test each water flow device for proper operation and verify the alarm is received in the CON. 7. Test each supervisory switch to verify proper operation. 8. Test the low air pressure alarm for proper operation. 9. Test the quick opening device. 10. Test the priming water level. 11. After completion, update the inspection card to reflect the date of inspection, person performing inspection, and company name. 12. Contractor to provide Westinghouse with documentation within 14 days stating that the tested system meets quarterly inspection requirements as required by NPPA 25. ANNUAL: one performance per system, per fiscal year of the following: Work should include, but is not limited to the following: 1. Inspection of all system components for damage 2. Verification of proper System activation 3. Verification of indications and alarms. 4. Clean, lubricate and verification of proper operation of valves. Repair as necessary 5. Inspection and cleaning of filters and strainers 6. Inspection of fire department connections and replacement of components as necessary. 7. Verification of proper operation of automatic drains, check valves and miscellaneous system components. 8. Verification of proper water pressures. 9. Verification of proper spare parts and tools in the riser cabinet 10. Reset system 11.Contractor shall Update the inspection tag to reflect the date and system condition. 12. Contractor to provide Westinghouse with documentation stating that the tested system meets annual inspection requirements as required by NPPA 25 within 14 days. Tag Number list: 03-PMB-SPRINKLER 03-CHB-SPRINKLER 03-CHB-UPA-SPINKLER WA9-0307 PURPOSE OF PROCUREMENT AND SCOPE OF WORK All parts, materials and tools will be provided by the contractor. Contractor(s) will participate in the Pre-Job Briefings to insure that good communications is established with WANCDF Engineering, Operations and Maintenance departments before any work begins. Extreme caution shall be taken to insure that unplanned outages will not occur. Westinghouse Anniston (WA) is soliciting the services of a Field Service Technician (Prefer Certified Fire Protection Company) to perform quarterly and Annual inspection, testing and certification of the gate 5A warehouse wet pipe sprinkler system. All inspection and testing shall be in accordance with NFPA 72 and 25. QUARTERLY: 4 performances per fiscal year. 1. The quarterly test shall include testing of each water flow alarm, priming water, low air pressure alarm, and each supervisory switch. 2. A main drain test shall be performed in accordance with NFPA 25. Readings shall be provided to Westinghouse for evaluation. 3. Inspect all gauges to verify they are in their proper operating ranges, no leaks are present, and there is no physical damage. Every fifth year each gauge shall be replaced using vendor provided gauges. 4. A visual inspection of each sprinkler system shall be conducted to insure the integrity of the piping, supports, clamps, and sprinkler heads. 5. Each water flow device shall be tested in accordance with NFPA 25. 6. Fire department connections shall be inspected. 7. Each supervisory switch shall be tested. ANNUAL: One performance per fiscal year. 1. The annual test shall include a complete inspection of the sprinkler system to insure the integrity of the piping, supports, clamps, and sprinkler heads. 2. All control valves shall be inspected, correct position verified, and tested in accordance with NFPA 25. 3. System strainers and filters shall be inspected and cleaned as required. 4. Each valve that requires lubrication shall be lubricated and operated as per the manufacturers recommendation. 5. Each tamper switch shall be tested for proper operation. 6. Each manual device shall be operated through its entire range. 7. Inspect fire pump casing and relief valves. 8. Verify all fire pump and jockey pump electrical switches are in their proper position. 9. Inspect alignment of the fire pump coupling. 10. Verify packing glands are properly adjusted. 11. Perform a 150% fire pump peak load test and record flow rates. 12. Perform 10 automatic starts. 13. Perform 10 manual starts. 14. Verify automatic and manual stops function properly. 15. If required replace the graph paper. 16. Record all pressure, RPM, and GPM readings as specified in NFPA 25. 17. At the completion of testing, shall provide Westinghouse with written documentation stating each sprinkler system meets all NFPA requirements. 18. An inspection card provided by the vendor shall be updated after each inspection and placed at each riser. The vendor, at the completion of the test, shall provide Westinghouse with written documentation stating each sprinkler system meets all NFPA requirements. An inspection card provided by the vendor shall be updated after each inspection and placed at each riser. Westinghouse will provide the vendor with the date the inspection is scheduled. The vendor shall be responsible to have a certified technician onsite for each scheduled inspection. SCHEDULE OF WORK: The schedule will be determined by Westinghouse. It may vary slightly due to operations ability to release each system. QUESTIONS REGARDING THIS SCOPE OF WORK General Questions and questions regarding contractual matters, payments, site access, or required training should be directed to Ashley Rollins@ +1 (555) 000-0000 (ext. 131). POC Jerry Skinner +1 (555) 000-0000 (Ext. 2045).

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS