Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of The Interior was posted on July 1, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Annual Elevator Safety Testing and Certification

Closed
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541380
New
Federal
J065--RO Equipment Maintenance
Solicitation # 36C25027Q0051
Solicitation 36C25027Q0051 is a request for quotes for a firm-fixed-price contract to provide preventive and non-routine emergency maintenance services for reverse osmosis equipment systems at the Ann Arbor VA Medical Center in Michigan. The scope of work covers systems serving the Laboratory Department and Sterile Processing Service, requiring adherence to OEM instructions and AAMI standards. The anticipated period of performance begins January 8, 2027, and extends through January 7, 2032, consisting of a one-year base period and four optional one-year extensions. This procurement is 100% set aside for small businesses under NAICS code 541380. The government will evaluate offers based on technical capability and past performance, with the total evaluated price including all option years and a six-month extension under FAR 52.217-8. Offerors must be registered in the System for Award Management and submit their quotes electronically to the contracting officer. Required submission documents include a signed SF1449, a strict adherence to the price schedule, and a past performance list from the last three years. Technical volumes are limited to ten pages. Awarded contractors must ensure personnel complete mandatory VA privacy and security training and provide all necessary certifications within three business days of the award.
250-NETWORK Contract Office 10 (36C250)

POSTED

about 3 hours ago

DEADLINE

in 19 days

AI Contract Overview

Show more

The contract entails a full annual safety inspection and testing of the elevator system in compliance with ASME A17.1/CSA B44 standards, ensuring all components are functionally sound and meet national safety requirements. The work includes comprehensive diagnostic testing, operational checks, mechanical evaluations, and the preparation of detailed documentation that must be submitted to designated facility representatives upon completion. All findings, corrective actions, and certification records are to be formally documented and delivered in accordance with regulatory protocols. This subcontract is issued under NAICS code 541380 and is administered by the Department of the Interior through its Imr Northern ROCKIES(12200) office. The solicitation was posted on July 1, 2026, with a firm response deadline of July 14, 2026, at 9:00 PM. The contract requires strict adherence to federal safety codes and expects timely, accurate reporting to maintain compliance. Performance location details are not specified, but the work is expected to occur at facilities under the jurisdiction of the Department of the Interior. All deliverables must align with the technical and procedural requirements of the referenced elevator safety standards.

General Info

Annual elevator safety inspection and testing per ASME A17.1/CSA B44 for Department of the Interior facilities.

NAICS

541380 - Testing Laboratories and Services

Place of Performance

WY

Set-Aside

NONE

Documents

This scope was carved out of 140P1426Q0103.

The full solicitation package (1 document), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

J--LIBI OTIS ELEVATOR SERVICE CONTRACT

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

subcontract

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of The Interior → Imr Northern ROCKIES(12200)
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Full annual safety inspection and testing of the elevator system, including documentation and submission to facility representatives per ASME A17.1/CSA B44.

More opportunities from Department Of The Interior → Imr Northern ROCKIES(12200)

Same awarding agency

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS