Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

Anti-Embolism_Hosiery

Active
MW-1412-07Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Defense Health Agency’s Medical Logistics Division, in coordination with the Defense Logistics Agency Troop Support Medical Prime Vendor Program, is seeking qualified suppliers to establish a Qualified Suppliers Listing (QSL) for Anti-Embolism Hosiery. This sources sought notification is aimed at gathering vendor information and products for evaluation, not a request for proposals or quotes. The hosiery products will be purchased by Military Treatment Facilities across the Military Health System and operational units from all military branches, with management handled by regional MMESO offices. Vendors must participate through the Medical/Surgical Prime Vendor Program and ensure their products comply with the Trade Agreements Act (TAA), providing necessary certifications and country of origin information. The QSL establishment is anticipated around August 2016, with selected vendors invited to submit pricing proposals for an Incentive Agreement. The government retains discretion on standardization decisions for these items. Vendors interested must respond with detailed information and meet strict qualifications, including holding or applying for a Distribution and Pricing Agreement (DAPA), having agreements with prime vendors CARDINAL HEALTH and OWENS & MINOR, and possessing an active Commercial and Government Entity (CAGE) code in the System for Award Management (SAM). The required anti-embolism hosiery products must meet specific performance criteria such as gradient pressure levels of 15-20 mm/Hg, be latex-free, reusable, washable, and include measuring aids in each package. Vendors will also be expected to provide in-service training support upon request. Sixteen specific hosiery items represent the core product line, with optional items also accepted under similar conditions. Submitted products will undergo clinical and logistical review by a Joint Product Review Board and clinical advisory committees, with samples evaluated at multiple Military Treatment Facilities. Vendors who meet all submission and product requirements will be notified of qualification status, enabling participation in subsequent purchasing actions.

General Info

Seeking qualified suppliers for TAA-compliant anti-embolism hosiery for Military Treatment Facilities.

Agency

N/A

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

Medical Materiel Enterprise Standardization Office (MMESO) West 34960 Bob Wilson Dr., SAN DIEGO, CA, 92134, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

3 updates
PhaseCombined Synopsis
Posted

Combined Synopsis

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Notice updated

The response deadline was removed. The notice description changed. The point of contact changed.

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyN/A
Contacts2 people available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts
Mr. Ricardo U. OriasMMESO West Team Leader
Mr Redentor SeseMMESO West Clinical Analyst

Full Description

Show more
The Defense Health Agency (DHA) Medical Logistics (MEDLOG) Division Medical Materiel Enterprise Standardization Office (MMESO) and the Defense Logistics Agency (DLA) Troop Support Medical Prime Vendor (PV) Program announce a Sources Sought Notification for the creation of a Qualified Suppliers Listing (QSL) for Anti-Embolism Hosiery. This is not a request for quote or proposal. The MMESO West is the lead MMESO for this project. These Anti-Embolism Hosiery products are for purchase by the Military Treatment Facilities (MTFs) of the Military Health System (MHS) and for the operational assemblages of the Army, Navy, Air Force, Marine Corps, and Naval Expeditionary Medical Support Command (NEMSCOM) and managed regionally by MMESOs North, South, West, Pacific and Europe, hereafter referred to as MMESOs. For information regarding DLA Troop Support Medical's PV program please access its web site at https://www.medical.dla.mil. This Sources Sought notification is intended to solicit information and products for evaluation in order to create a QSL for Anti-Embolism Hosiery in accordance with (IAW) FAR 9.2. All items proposed to be included in this QSL must be on a Distribution and Pricing Agreement (DAPA) for the DLA Troop Support Medical/Surgical Prime Vendor (MSPV) Program. All participating vendors must complete the certification in the DAPA Management System (DMS). The MSPV Program requires that all items be manufactured in a Trade Agreements Act (TAA) Compliant Country (see DFARS 252.225-7020 AND 252.225-7021), unless it is determined that no functionally equivalent item is available from a compliant source. To be eligible for inclusion in the proposed QSL, all vendors are required to provide country of origin information in the QSL FBO Package Worksheet. In addition, according to the DAPA Terms and Conditions, you must complete the DAPA TAA Certification for each item offered. If an item offered is a TAA Non-Compliant End Product, the Government can use this information to determine whether or not a waiver exists or if the Government will seek a waiver for the item. Unless a waiver exists or is granted, TAA Non-Compliant County End Products cannot be added to the QSL and/or DAPA. Any questions concerning TAA may be directed to Donna Raday at DLA Troop Support, donna.raday@dla.mil, 215-737-7885. The QSL for Anti-Embolism Hosiery will be established approximately August 2016 and is anticipated to be the basis of a Standardization Action. Qualified vendors will be invited approximately September 2016 to submit pricing proposals to enter into an Incentive Agreement for Anti-Embolism Hosiery. The government reserves the right to standardize or not standardize on Anti-Embolism Hosiery. A. Products & Performance Required. The MMESOs are seeking product line items in the category of Anti-Embolism Hosiery. Within the MHS MTFs and operational procurement this product line has an estimated annual sales volume of $271,653.00. This forecast is based on historical usage data during a recent 12-month period. Sixteen items are required for addition to the QSL and account for 85.59 % ($232,500) of the total volume in sales ($271,653.00). The specifications for this project are shown in "Requirements to Qualify for QSL" section below. B. Instructions to Vendors Vendors interested in qualifying for inclusion in the QSL must provide an e-mail response to this QSL FBO Sources Sought notification to the lead MMESO POCs below. The vendor's responses must include all detailed information requested in the "Requirements to Qualify for QSL" section below and must also include: (1) Company name and address; (2) Company POC (Name and Phone Number, Fax Number, and E-mail address); (3) Commercial and Government Entity (CAGE) Code; and (4) Identification of the Sources Sought notification to which the vendor is responding. Due to the potential for e-mail to be lost in transmission, from network security, etc., vendors are strongly encouraged to confirm with the lead MMESO that their e-mail submission has arrived. Each submitting vendor is advised to confirm receipt, allowing adequate time for resubmission before the due date and time should a problem occur with the first submission. As part of the "Requirements to Qualify for QSL", vendors must complete and submit the QSL FBO Package Worksheet. Any vendor experiencing difficulty opening the Worksheet may contact the MMESO POCs. The MMESO POC will provide a Worksheet copy via an alternate method (fax, email or hard copy). Vendors that do not meet the deadline of COB 5:00 PM Pacific Standard Time (PST) on the date listed for closing in this QSL FBO Sources Sought notification will not be included in the lead MMESO's review to establish the QSL and thus will not be able to participate in the subsequent Standardization Action. C. Source Selection Procedures The MMESO Joint Product Review Board (JPRB) will serve as the forum for clinical recommendations for product selection and coordinate logistics efforts in support of DoD Components. The board is chaired by Designated Senior Logisticians (DSLs) and co-chaired by Designated Senior Clinicians (DSCs) in the MMESO Areas of Responsibility (AORs) and includes clinicians and logisticians for MTFs within each MMESO. The Clinical Advisory Committee (CAC) members are the deciding officials for this initiative. The MMESO DSLs and DSCs intend to review responses and evaluate products for selection to the QSL IAW FAR 9.2. Requirements to Qualify for QSL The requirements for this product line are outlined below. Complete answers and all supporting documentation must be provided with the vendor's submittal by the response date stated in this QSL FBO Sources Sought notification. A vendor who does not meet all of these requirements or who does not submit documentation to support these requirements as requested will not be qualified for the QSL. Vendors must provide responses to this Sources Sought notification via the QSL FBO Package Worksheet. 1. Vendor must have a DAPA or be in the process of applying for a DAPA number for the product line listed. Vendor must provide their DAPA number or provide documentation and date the DAPA number was applied for. Vendors who do not continue to process application for a DAPA number will not be considered for continued participation. 2. Vendor must have an agreement with the current DoD Medical/Surgical Prime Vendor CARDINAL HEALTH, or must work with CARDINAL HEALTH to initiate an agreement. 3. Vendor must have an agreement with the current DoD Medical/Surgical Prime Vendor OWENS & MINOR, or must work with OWENS & MINOR to initiate an agreement. 4. Vendor must have a government issued Commercial and Government Entity (CAGE) code assigned for products contained within the specific product group or be in the process of obtaining one. Vendors must validate that their account is Active in the System for Award Management (SAM) and provide CAGE Code. Vendors in the process of obtaining a CAGE Code must provide documentation to support that they have registered in SAM. Vendors who do not continue to process application for a CAGE Code and/or a SAM account will not be considered for continued participation. See https://www.sam.gov/portal/public/SAM/. 5. Vendor offered products should be TAA compliant. End-items offered shall be manufactured or substantially transformed either in the U.S. or in Designated or Qualifying countries. Therefore, the vendor at the item level must provide country of origin for all required items and any optional items offered. Vendor must provide product catalog & literature for any items offered in response to this Sources Sought Notification. Vendor must submit the following information via QSL FBO Package Worksheet for each offered product: Full item description, Distributor Part Number, Manufacturer Part Number, Manufacturer Name, Number of eaches in Unit of Sale, and country of origin. Only ONE Vendor Part Number (PN) should be provided for each item/sample. Required Product / Annual usage in units / 1. ANTI-EMBOLISM HOSIERY, THIGH, INSPECTION TOE, LARGE/REG (CALF CIRCUMFERENCE 14"- 17.5"/35.5 CM - 44.5 CM , THIGH CIRCUMFERENCE 23" - 27"/58.5 CM - 68.5 CM, LENGTH 29" - 33"/74CM - 84 CM) / 8,147 / 2. ANTI-EMBOLISM HOSIERY, THIGH, INSPECTION TOE, MEDIUM/REG (CALF CIRCUMFERENCE12" - 15"/30 CM - 38.1 CM, THIGH CIRCUMFERENCE 16" - 29"/41 CM - 74 CM, LENGTH 29" - 33"/74CM - 84 CM) / 7,379 / 3. ANTI-EMBOLISM HOSIERY, KNEE, INSPECTION TOE, MEDIUM/REG (CALF CIRCUMFERENCE 12" - 15"/30 CM - 38.1 CM , LENGTH 14" - 17"/36 CM - 43 CM) / 6,334 / 4. ANTI-EMBOLISM HOSIERY, KNEE, INSPECTION TOE, LARGE/REG (CALF CIRCUMFERENCE 12" - 17.5"/35.5 CM - 44.5 CM , LENGTH 14" - 18"/36 CM - 46 CM) / 5,586 / 5. ANTI-EMBOLISM HOSIERY, THIGH, INSPECTION TOE, LARGE/LONG (CALF CIRCUMFERENCE 14"- 18"/35.5 CM - 46 CM , THIGH CIRCUMFERENCE 16" - 29"/41 CM - 74 CM, LENGTH 31" - 38"/79 CM -97 CM) / 5,293 / 6. ANTI-EMBOLISM HOSIERY, THIGH, INSPECTION TOE, X-LARGE/REG (CALF CIRCUMFERENCE 16" - 21.5"/40.5 CM - 54.5 CM, THIGH CIRCUMFERENCE 24" - 33"/61 CM - 81.5 CM, LENGTH 29" - 33"/74 CM - 84 CM / 4,032 / 7. ANTI-EMBOLISM HOSIERY, KNEE, INSPECTION TOE, XLARGE/REG (CALF CIRCUMFERENCE16" - 20"/36 CM - 51 CM, LENGTH 14" -18"/36 CM - 46 CM) / 3,172 / 8. ANTI-EMBOLISM HOSIERY, THIGH, INSPECTION TOE, MEDIUM/LONG (CALF CIRCUMFERENCE 12" - 15"/30.5 CM - 38.1 CM, THIGH CIRCUMFERENCE 19" - 24"/48 CM - 63.5 CM, LENGTH 31" - 38"/84 CM -97 CM) / 2,447 / 9. ANTI-EMBOLISM HOSIERY, KNEE, INSPECTION TOE, SMALL/REG(CALF CIRCUMFERENCE 9" - 13"/23 CM -33 CM, LENGTH 14" - 17"/36 CM - 43 CM) / 2,149 / 10. ANTI-EMBOLISM HOSIERY, KNEE, INSPECTION TOE, LARGE/LONG (CALF CIRCUMFERENCE 14" - 19"/35.5 CM - 45 CM, LENGTH 17" - 20"/43 CM - 51 CM) / 2,016 / 11. ANTI-EMBOLISM HOSIERY, THIGH, INSPECTION TOE, SMALL/REG (CALF CIRCUMFERENCE 9" - 13"/ 23 CM - 33 CM , THIGH CIRCUMFERENCE 16" - 29"/41 CM - 74 CM, LENGTH 29" - 33"/74 CM - 84 CM) / 1,846 / 12. ANTI-EMBOLISM HOSIERY, KNEE, INSPECTION TOE, X-LARGE/LONG, (CALF CIRCUMFERENCE 16" - 20"/40.5 CM - 51 CM, LENGTH 17" - 20"/43CM - 51 CM) / 1,343 / 13. ANTI-EMBOLISM HOSIERY, THIGH, INSPECTION TOE, X-LARGE/LONG (CALF CIRCUMFERENCE 16" - 21.5"/40.5 CM - 55 CM, THIGH CIRCUMFERENCE 24" - 32"/61 CM - 81.5 CM, LENGTH 31" - 38"/79 CM -97 CM) / 1,204 / 14. ANTI-EMBOLISM HOSIERY, KNEE, INSPECTION TOE, MEDIUM/LONG, (CALF CIRCUMFERENCE 12" - 15"/30.5 CM - 38 CM, LENGTH 17" - 20"/43 CM - 51 CM) / 1,127 / 15. ANTI-EMBOLISM HOSIERY, THIGH, INSPECTION TOE, MEDIUM/SHORT (CALF CIRCUMFERENCE 12" - 15"/30.5 CM - 38.1 CM, THIGH CIRCUMFERENCE 16" - 29"/41 CM - 74 CM, LENGTH 25" - 29"/64CM - 74 CM) / 946 / 16. ANTI-EMBOLISM HOSIERY, THIGH, INSPECTION TOE, LARGE/SHORT (CALF CIRCUMFERENCE 14"- 17.5"/35.5 CM - 44.5 CM, THIGH CIRCUMFERENCE 16" - 29"/41 CM - 74 CM, LENGTH 25" - 29"/64CM - 74 CM) / 780 / 6. Vendor must provide Anti-Embolism Hosiery products with gradient pressure at the ankle of 15-20mm/hg and provide documentation to support this with initial submittal. 7. Vendor must provide Anti-Embolism Hosiery products that are not made with natural rubber latex and provide documentation to support this with initial submittal. 8. Vendor must provide Anti-Embolism Hosiery products that are reusable and washable and provide documentation to support this with initial submittal. 9. Vendor must provide Anti-Embolism Hosiery products that include a measuring tape and a sizing chart in each package and provide documentation to support this with initial submittal. 10. Vendor must be able to provide in-service training as requested by the MTFs. This in-service may be accomplished through the use of DVDs, in person training sessions, or written materials. 11. Vendor must provide Anti-Embolism Hosiery products that leave no skin breakdown while being worn. 12. Vendor must provide Anti-Embolism Hosiery products that do not roll down while being worn. 13. Vendor MAY provide any or all of the optional items listed below, following the same format as for requirement number 5. Item Descriptions / 1. ANTI-EMBOLISM HOSIERY, THIGH, CLOSED TOE, LARGE/REG (CALF CIRCUMFERENCE 14"- 17.5"/35.5 CM - 44.5 CM , THIGH CIRCUMFERENCE 23" - 27"/58.5 CM - 68.5 CM, LENGTH 29" - 33"/74 CM - 84 CM) / 2. ANTI-EMBOLISM HOSIERY, THIGH, INSPECTION TOE, SMALL/SHORT (CALF CIRCUMFERENCE 9" - 13"/ 23 CM - 33 CM, THIGH CIRCUMFERENCE 16" - 29"/40.5CM - 74 CM, LENGTH 25" - 29"/64 CM - 74 CM) / 3. ANTI-EMBOLISM HOSIERY, THIGH, INSPECTION TOE, SMALL/LONG (CALF CIRCUMFERENCE 9" - 13"/ 23 CM - 33 CM , THIGH CIRCUMFERENCE 16" - 29"/41 CM - 74 CM, LENGTH 31" - 38"/79 CM - 97 CM) / 4. ANTI-EMBOLISM HOSIERY, THIGH, CLOSED TOE, LARGE/LONG (CALF CIRCUMFERENCE 14"- 18"/35.5 CM - 46 CM , THIGH CIRCUMFERENCE 16" - 29"/41 CM - 74 CM, LENGTH 31" - 38"/79 CM -97 CM) / 5. ANTI-EMBOLISM HOSIERY, KNEE, CLOSED TOE, XLARGE/REG (CALF CIRCUMFERENCE16" - 20"/36 CM - 51 CM, LENGTH 14" -18"/36 CM - 46 CM) / 6. ANTI-EMBOLISM HOSIERY, KNEE, CLOSED TOE, MEDIUM/REG (CALF CIRCUMFERENCE 12" - 15"/30 CM - 38.1 CM , LENGTH 14" - 18"/36 CM - 43 CM) / 7. ANTI-EMBOLISM HOSIERY, KNEE, CLOSED TOE, LARGE/LONG (CALF CIRCUMFERENCE 14" - 19"/35.5 CM - 45 CM, LENGTH 17" - 20"/43 CM - 51 CM) / 8. ANTI-EMBOLISM HOSIERY, KNEE, CLOSED TOE, X-LARGE/LONG, (CALF CIRCUMFERENCE 16" - 20"/40.5 CM - 51 CM, LENGTH 17" - 20"/43CM - 51 CM) / 9. ANTI-EMBOLISM HOSIERY, KNEE, CLOSED TOE, SMALL/REG(CALF CIRCUMFERENCE 9" - 13"/23 CM -33 CM, LENGTH 14" - 17"/36 CM - 43 CM) / 10. ANTI-EMBOLISM HOSIERY, KNEE, INSPECTION TOE, SMALL/LONG (CALF CIRCUMFERENCE 9" - 13"/23 CM -33 CM, LENGTH 16" - 20"/40.5 CM - 51 CM) / 11. ANTI-EMBOLISM HOSIERY, KNEE, CLOSED TOE, SMALL/LONG (CALF CIRCUMFERENCE 9" - 13"/23 CM -33 CM, LENGTH 16" - 20"/40.5 CM - 51 CM) / 12. ANTI-EMBOLISM HOSIERY, KNEE, INSPECTION TOE, XX-LARGE/LONG (CALF CIRCUMFERENCE 18" - 23"/46 CM - 58.5 CM, LENGTH 17" - 20"/43 CM - 51 CM)) / 13. ANTI-EMBOLISM HOSIERY, KNEE, INSPECTION TOE, XX-LARGE/REG (CALF CIRCUMFERENCE 18" - 23"/45 CM - 60 CM, LENGTH 16" - 18"/41 CM - 46 CM) / 14. ANTI-EMBOLISM HOSIERY, THIGH, INSPECTION TOE, XX-LARGE/LONG (CALF CIRCUMFERENCE 18" - 26"/46 CM - 66 CM, THIGH CIRCUMFERENCE 32" - 36"/81 CM - 92 CM, LENGTH 32" - 38"/81 CM - 97 CM) / 15. ANTI-EMBOLISM HOSIERY, THIGH, INSPECTION TOE, XX-LARGE/REG (CALF CIRCUMFERENCE 18" - 26"/46 CM - 66 CM , THIGH CIRCUMFERENCE 32" - 36"/81 CM - 92 CM, LENGTH 25" - 33"/64 CM - 84 CM) / 14. All products offered should be TAA compliant. End-items offered shall be manufactured or substantially transformed either in the U.S. or in Designated or Qualifying countries. Therefore, the vendor at the item level must provide country of origin for all required items and any optional items offered. Evaluation After the lead MMESO receives all information required above, they will send each vendor making a complete and approved submission a written request to provide product samples to the Evaluation Site Leader (ESL) at the participating MTFs. MTF "Ship to" Addresses will be provided as part of the request. To ensure your eligibility to participate, all products required for evaluation must be shipped no later than 14 calendar days from issuance of the MMESO's request and must arrive at all designated MTFs no later than 5:00 PM local time at delivery location, 30 calendar days from issuance of the MMESO's request. Any products received after the stated date and time will not be included in review to establish the QSL and to participate in the subsequent Standardization Action, and will be destroyed upon receipt. Vendor will provide only the following products for evaluation. The products will be provided at no cost to the government for products or delivery, and unused products will not be returned. Ten (10) pairs each of the required items listed are to be provided as product samples to each of the evaluation sites as requested by the Lead MMESO. Vendor will be required to supply the same part number(s) submitted in the QSL FBO Package Worksheet. Items for Evaluation / 1. ANTI-EMBOLISM HOSIERY, THIGH, INSPECTION TOE, LARGE/REG (Calf Circumference 14"- 17.5"/35.5 cm - 44.5 cm , Thigh Circumference 23" - 27"/58.5 cm - 68.5 cm, Length 29" - 33"/74cm - 84 cm) / 2. ANTI-EMBOLISM HOSIERY, THIGH, INSPECTION TOE, MEDIUM/REG (Calf Circumference12" - 15"/30 cm - 38.1 cm, Thigh Circumference 16" - 29"/41 cm - 74 cm, Length 29" - 33"/74cm - 84 cm) / 3. ANTI-EMBOLISM HOSIERY, THIGH, INSPECTION TOE, LARGE/LONG (Calf Circumference 14"- 18"/35.5 cm - 46 cm , Thigh Circumference 16" - 29"/41 cm - 74 cm, Length 31" - 38"/79 cm -97 cm) / There will be approximately 5 MTFs enterprise wide that will be evaluating products. Each evaluator will evaluate the vendor submissions in the Anti-Embolism Hosiery product line. The MMESO Evaluation Site Leader will review the responses from the vendors and the results from the product evaluations and determine which vendors meet the requirements. A vendor who provides all requested information and meets the requirements will be selected for inclusion in the QSL. Vendors will be notified of whether they met or did not meet the QSL requirements by approximately August 2016. Points of Contact (POCs): Mr. Ricardo Orias, MMESO West Team Leader, ricardo.u.orias.ctr@mail.mil, (619) 532-8537; and Mr. Redentor Sese, RN, MMESO West Clinical Analyst, redentor.p.sese.ctr@mail.mil (619) 532-8517. DLA Troop Support Medical Contracting Officer: Tara J. Perrien, tara.perrien@dla.mil (215) 737-8307. The purpose of this Modification is to attach an updated QSL FBO Worksheet Package. Please refer to "QSL FBO Package Worksheet MW-1412-07 Anti-Embolism Hosiery - UPDATED" There are no other changes at this time. The purpose of this Modification to the QSL FBO is to inform vendors on the QSL List that the Incentive Agreement FBO has now been posted. Only Vendors on the QSL for this product line can be considered for an IA. All solicitation information is available electronically on the Federal Business Opportunities website. Solicitation External Reference: https://www.fbo.gov/spg/DLA/J3/DSCP-M/IAW-1607-02/listing.html Solicitation External Reference To Packages: https://www.fbo.gov/spg/DLA/J3/DSCP-M/IAW-1607-02/packages.html

Similar Contracts

Same NAICS industry code

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS