Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

Anti Terrorism Force Protection Melrose Air Force Range

Active
FA4855-16-B-0024Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

NAICS

236220 - Commercial and Institutional Building Construction

Place of Performance

Melrose Air Force Range 3771 Sundale Valley Road, FLOYD, NM, 88118, USA

Set-Aside

NONE

Documents

1

FA4855-16-B-0024 Pre-solicitation Notice for Minor Construction at Melrose Air Force Range

DOCX, High priority: read this firstpresolicitation
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhasePresolicitation
Posted

Sources Sought

Type Changed

Sources Sought → Presolicitation

Notice updated

The notice description changed. The point of contact changed.

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA4855 27 Socons Lgc
Contacts2 people available
OfficeCANNON AFB, NM, 88103-5321, USA
Office AddressCANNON AFB, NM, 88103-5321, USA
Contacts
Tessa L. SmithAnti Terroism Force Protection Melrose Air Force Range
Bonnie L. YoakumContracting Officer

Full Description

Show more
Construction to install Anti-Terrorism Force-Protection Upgrades at Tactical Operation Center & PEC, MAFR The 27 Special Operations Contracting Squadron (27 SOCONS) is seeking information concerning the availability of capable contractors to provide minor construction to correct potential security standard deficiencies at multiple areas that require additional Antiterrorism and Force Protection. This Sources Sought (SS) is issued for informational and planning purposes only. This is not a Request for Proposal (RFP). It is not to be construed as a commitment by the Government to issue a solicitation or ultimately award a contract. Responses will not be considered as proposals, nor will any award be made as a result of this RFI. The Air Force will NOT be responsible for any costs incurred by interested parties in responding to this RFI. Contact with Government personnel other than those specified in this RFI by potential offerors or their employees' regarding this project is prohibited. This FedBizOpps notice is an announcement seeking market information on vendors capable of providing the services as described herein. 27 SOCONS is currently conducting market research to locate qualified, experienced, and interested potential sources. The information requested by this SS will be used within the Air Force to facilitate decision making and will not be disclosed outside the agency. For purposes of this SS, the North American Industry Classification System (NAICS) Code is 236220, Commercial and Institutional Building Construction, and the small business size standard is $36.5M. Description of Services Sundale Valley Road Entry Control Point (ECP) Install around the ECP facility approximately 200 linear feet (lf) of new 8' high type FE6 chain-link security fence with barbed wire on a single outrigger (refer to attached drawings). Ensure a 15' standoff distance between the fence and the facility. Install a 3' wide manually operated personnel swing gate to the new fence that matches the same FE6 type construction (refer to attached drawing). Install a 9' wide manually operated double swing vehicle gate to the fence that matches the same FE6 type construction (refer to drawings for locations). Remove and replace the existing swing arm gate with a new electrically powered K4 crash rated swing arm gate. Install access controls for the gate at the desk inside the ECP facility Ensure gate is also equipped and setup with Internet Protocol (IP) access capabilities for other locations to open and close the gate. Return the existing gate to the government. Run the power to the new gate from the 60 Amp, single phase electrical panel that powers the gate currently. Provide shop drawings for all electrical connections. Install two high pressure sodium spot lights at 15' high on the existing pole next to the entrance. Aim lights to shine on the swing arm gate. Install an IP security camera to the same pole close to the new swing arm gate that will surveil access through the new gate. Run the power to the new lights from the 60 Amp, single phase electrical panel that powers the gate currently. Provide shop drawings for all electrical connections. Provide and place 10' long concrete jersey barriers no more than 4' apart in a line along the north side of Sundale valley road leading up to the gate for approximately 100'. Provide and place 10' long concrete jersey barriers in a serpentine layout, adequately spaced to accommodate access of an 18 wheeler truck, just outside of the gate entrance (refer to drawing). Provide and place 10' long concrete jersey barriers in a serpentine layout, adequately spaced to accommodate access of an 18 wheeler truck, just inside of the gate entrance (refer to drawing). Ground Electric Combat Control Operation (GECCO)/ Tactical Operation Center (TOC) Install approximately 1360lf of new 8' high type FE6 chain-link security fence with barbed wire on a single outrigger around the area west of the GECCO/TOC existing fence line (refer to attached drawings). Connect new fence into the existing fence line to completely close off newly fenced area. Install a manually operated 16' wide double swing vehicle gate on east side of the new fence (refer to attached drawing for location) Install a new electronically powered vehicle security gate (not k4 crash rated) to the new fence at the road (refer to attached drawing for location) Install an IP security camera to the electrical service pole closest to the new swing arm gate that will surveil access through the new gate. Run 60 Amp, single phase power below ground to the gate and light pole from the nearby transformer, to include service disconnect , panel, wire, conduit, trenching, and any other associated item to make the connection. If your firm is capable of providing the requirements described above, please provide a Capability Statement to SrA Tessa Smith by 1 AUGUST 2016 @ 1400 MST. The Capability Statement should include general information and technical background describing your firm's experience in constructing similar efforts. Interested parties shall not submit more than 2 single-sided, type-written pages using 12-point font or larger. Published literature may be any number of pages. At a minimum the following information is requested: (1) Company Cage Code, DUNS, name, address, point of contact and their telephone number and e-mail address; (2) Bonding capability (3) Any small business status (8(a), HUB Zone, veteran-owned, women-owned, etc.); (4) Indicate if your role in the performance of the consolidated requirement would be (a) Prime Contractor; (b) Subcontractor (5) If you indicated your role as "Prime Contractor" on Question 4, indicate the functions for which you plan to self-perform as a percentage of the total and those which you intend to use as subcontractors; particularly for the electrical, plumbing and HVAC requirements.; (6) If you indicated your roll will be a "Subcontractor" on Question 4, please indicate which functional areas you intend to cover; (7) Indicate if your company primarily does business in the commercial or Government sector (8) Indicate which NAICS code(s) your company usually performs under for Government contracts. Note: The interested vendors list of this notice will not be used for decision making purposes for any small business set asides. For your business to be considered as a potential vendor for set aside purposes you must submit a Capabilities Statement as requested by this notice. Failure to do so may result in your business category not being considered as part of a decision by the government to set aside.

Similar Contracts

Same NAICS industry code

NAICS: 236220
New
Construction of the Recharge Master Plan Update Basin Improvements Project Montclair Basin Improvements
Solicitation # construction-recharge-master-plan-update-basin-improvements-project-montclair-basin-improvements-2
The Construction of the Recharge Master Plan Update Basin Improvements Project Montclair Basin Improvements is a solicitation issued by RT Contractor Corp for the Inland Empire Utilities Agency. This project, located in California with a specific performance area in Riverside or Los Angeles, focuses on basin improvements under NAICS code 236220. The solicitation was posted on October 19, 2026, with a response deadline of November 4, 2026. This opportunity is specifically set aside for Disadvantaged Business Enterprises (DBE) as defined by the Department of Transportation. To secure project financing, the Inland Empire Utilities Agency requires strict adherence to expanded DBE Good Faith Effort (GFE) guidelines. Bidders must provide proof of utilizing SBA and MBDA services and demonstrate that solicitations were posted in an online publication for 30 consecutive days and in a newspaper for at least one day prior to the bid opening. Failure to include this documentation within the bid package will result in the proposal being deemed non-responsive. While outreach documentation may be submitted up to three business days after the closing date, all other mandatory GFE requirements must be met by the opening date to ensure compliance.
RT CONTRACTOR CORP

POSTED

about 4 hours ago

DEADLINE

in 15 days
View Details
NAICS: 236220
New
P084 NEXT GENERATION TORPEDO INTEGRATION LAB & P1016 Consolidated RDT&E Systems Facility – Newport, RI
Solicitation # p084-next-generation-torpedo-integration-lab-p1016-consolidated-rdte-systems-facility-newport-ri
J&J Contractors, Inc. is soliciting bids for the construction of the Next Generation Torpedo Integration Lab and the P1016 Consolidated RDT&E Systems Facility in Newport, Rhode Island. The project involves the development of a 12,920 square foot multi-story steel frame laboratory and office facility, as well as an optional 17,978 square foot laboratory facility. Construction features include shallow foundations, metal standing seam roofs, and exterior walls composed of masonry and metal panels. The scope of work encompasses comprehensive site preparations, including landscaping, parking, exterior lighting, and the installation of underground stormwater retention and utility systems. Additionally, the project requires the demolition of Building 1272T, a 548 square meter engineering facility. Pricing is requested across a wide array of trades, including demolition, abatement, concrete, masonry, structural and miscellaneous metals, millwork, roofing, drywall, flooring, painting, elevator installation, fire protection, plumbing, mechanical, electrical, sitework, and crane services. This is a small business set-aside solicitation subject to Davis Bacon Wage Rates and is exempt from sales tax. Interested parties must contact the primary point of contact to receive bid invitations and documents via Building Connected. The response deadline for this solicitation is November 30, 2026.
J&J CONTRACTORS, INC.

POSTED

about 4 hours ago

DEADLINE

in about 1 month
View Details
NAICS: 236220
New
CITY OF GREENFIELD WASTEWATER TREATMENT PLANT UPGRADE PROJECT
Solicitation # city-greenfield-wastewater-treatment-plant-upgrade-project
The City of Greenfield Wastewater Treatment Plant Upgrade Project involves the construction of a new 2.0 million gallons per day facility located on the northeast end of Walnut Avenue in Greenfield, California. The project scope is divided into four distinct phases: site preparation involving soil stabilization and utility relocation; construction of the plant including a packaged Membrane Bioreactor treatment plant, headworks, UV disinfection, and SCADA systems; decommissioning and demolition of existing facilities; and the completion of finish facilities including the Walnut Avenue extension. The total duration for the project is 915 calendar days, with a critical requirement to maintain existing plant services and regulatory compliance throughout the first two phases. Managed by C. Overaa & Co., the solicitation is open to various small and disadvantaged business enterprises, including DBE, SDVOSB, and WOSB. A significant local hiring goal requires that 50 percent of the total construction workforce be residents of Monterey, San Benito, or Santa Cruz counties. Subcontractors must utilize the Textura electronic system for invoicing and payments and are required to accept the standard Overaa agreement without modification. Key milestones include a mandatory pre-bid meeting on October 5, 2026, with bid submission deadlines listed as either October 28 or November 10, 2026.
C. Overaa & Co.

POSTED

about 4 hours ago

DEADLINE

in 21 days
View Details
NAICS: 236220
New
P1102 Weapons Magazine and Ordnance Operations Facility, Naval Submarine Base New London, Groton, Connecticut
Solicitation # p1102-weapons-magazine-ordnance-operations-facility-naval-submarine-base-new-london-groton
This solicitation issued by J & J Contractors, Inc. seeks pricing for the P1102 Weapons Magazine and Ordnance Operations Facility project at the Naval Submarine Base New London in Groton, Connecticut. The project has a duration of 1828 calendar days and involves the construction of six Containerized Long Weapons Storage units, two Box G magazines, and one Box H earth-covered high-explosive magazine. The scope includes comprehensive site work such as clearing, rock excavation, grading, and wetland mitigation, as well as the construction of an Ordnance Operations building, a Truck Inspection area, and a Sentry building. Demolition of 18 existing magazines and buildings 524 and 393 is also required. Technical requirements encompass a wide range of trades including demolition, abatement, concrete, structural steel, roofing, electrical, plumbing, and mechanical systems. Specialized construction features include rigid inclusions, load transfer mats, grounding and lightning protection, and intrusion detection systems. The project also involves installing primary and secondary electrical distribution, telecommunications infrastructure, access roads, and landscaping. This opportunity is set aside for various small business categories, and interested parties must contact the primary point of contact by the October 31, 2026, deadline to receive bid documents.
J & J Contractors, Inc

POSTED

about 4 hours ago

DEADLINE

in 11 days
View Details

More opportunities from Department Of Defense → FA4855 27 Socons Lgc

Same awarding agency

NAICS: 562910
New
Federal
Small Arms Firing Range (SAFR) Cleaning and Maintenance Services
Solicitation # FA485526Q0078
Solicitation FA485526Q0078 is a combined synopsis and request for quotation for a firm-fixed-price contract to provide cleaning and maintenance services for Small Arms Firing Ranges at Cannon Air Force Base, New Mexico. This total small business set-aside under NAICS 562910 covers the 27th Special Operations Security Forces Squadron and 26th Special Tactics Squadron Combat Arms Training and Maintenance facilities. The scope of work requires quarterly inspections and cleaning of bullet traps, HVAC systems, dust collection units, and firing point areas, with a specific focus on the removal of lead dust and fragments. All services must be performed in accordance with manufacturer specifications and federal standards, including OSHA and EPA regulations. The contract structure consists of a base year running from November 1, 2026, to October 31, 2027, with four subsequent one-year option periods. Award will be granted to the responsible offeror determined to be most advantageous based on technical capability, past performance, and price. Offerors must submit a completed pricing worksheet, offeror certification, and conflict of interest statement by the response deadline of October 23, 2026. Payment will be processed electronically through the Wide Area WorkFlow system. Special requirements include strict adherence to hazardous waste packaging and disposal protocols for contaminated materials and compliance with Department of Defense cybersecurity controls.
Remediation Services

POSTED

5 days ago

DEADLINE

in 3 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS