Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, August 5 at 2:00 PM EDT

Register Free →

ATON Battery Packs

Active
141016-26-0041Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of Commerce NoaaView Agency

NAICS

335910 - Battery ManufacturingView NAICS

Place of Performance

VA, USA

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

PhasePresolicitation
Posted

Presolicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Commerce Noaa
Contacts1 person available
OfficeNORFOLK, VA, 23510, USA
Organization / Agency
Department Of Commerce Noaa
View Agency Profile
Office AddressNORFOLK, VA, 23510, USA

Full Description

Show more

***THE NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION’S (NOAA) ACQUISITION & GRANTS OFFICE, EASTERN ACQUISITION DIVISION-NORFOLK, NATIONAL OCEAN SERVICE (NOS) CENTER FOR OPERATIONAL OCEANOGRAPHIC PRODUCTS AND SERVICES (CO-OPS), INTENDS TO NEGOTIATE AND AWARD A PURCHASE ORDER, ON A SOLE SOURCE BASIS, UNDER AUTHORITY OF RFO FAR 6.103-1, WITH WAREHOUSE BATTERY OUTLET, INC. FOR ATON BATTERY PACKS. NO SET ASIDE IS TO BE USED FOR THIS SOLE SOURCE REQUIREMENT. THE ASSOCIATED NAICS CODE IS 335910.


***THE SOLE SOURCE DETERMINATION IS BASED ON NOAA’S REQUIREMENT THAT WAREHOUSE BATTERY OUTLET INC. IS THE MANUFACTURER AND SOLE DISTRIBUTOR OF ATON BATTERY PACKS IN THE UNITED STATES. WAREHOUSE BATTERY OUTLET INC. DOES NOT HAVE ANY AUTHORIZED PARTNERS OR RESELLERS WHO CAN PROVIDE THESE PRODUCTS.


THE ATON, IATON, AND IATON V-2 ARE REAL-TIME OCEAN CURRENT MEASUREMENT SYSTEMS THAT AFFIX TO U.S. COAST GUARD (USCG) AIDS-TO-NAVIGATION (ATON) BUOYS. THESE SYSTEMS EMPLOY AN ACOUSTIC DOPPLER CURRENT PROFILER (ADCP) SENSOR TO MEASURE OCEAN CURRENTS. MOTIVATION FOR THE ATON AND IATON DESIGNS AND DEVELOPMENT CAME FROM THE NEED TO FULFILL PHYSICAL OCEANOGRAPHIC REAL-TIME SYSTEMS (PORTS®) USERS’ REQUESTS FOR REAL TIME VERTICAL CURRENT PROFILE INFORMATION IN OR NEAR SHIPPING CHANNELS. THE ATON VERSION OF THIS SYSTEM USES A RADIO TO COMMUNICATE WITH A SHORE STATION THAT TRANSMITS THE DATA BACK TO CO-OPS THROUGH NOAA’S GEOSTATIONARY OPERATIONAL ENVIRONMENTAL SATELLITES (GOES). THE IATON AND IATON V-2 VERSIONS OF THE SYSTEM UTILIZES IRIDIUM SHORT BURST DATA MODEMS TO TRANSMIT DATA DIRECTLY TO COOPS. THE 26 MN1300D BATTERY PACK MADE BY BATTERY WAREHOUSE OUTLET HAS BEEN THE STANDARD BATTERY PACK USED BY CO-OPS FOR THE ATON AND IATON SYSTEMS FOR OVER 20 YEARS. SINCE THE SYSTEMS ARE INSTALLED USCG ATON BUOYS THERE IS A REQUIREMENT FOR THE SYSTEM TO HAVE A LOW PROFILE THAT DOES NOT VISUALLY ALTER THE SHAPE OF THE BUOY. AS A RESULT, THERE IS LIMITED SPACE AVAILABLE AND THE BATTERY COMPARTMENTS OF THE SYSTEMS ARE DESIGNED TO ACCOMMODATE THESE BATTERY PACKS. THESE BATTERY PACKS WERE TESTED BY CO-OPS TO ENSURE THAT THEY WOULD BE ABLE TO POWER THE SYSTEMS THROUGH A FULL DEPLOYMENT AND WOULD NOT BE ADVERSELY AFFECTED BY THE HARSH ENVIRONMENTAL CONDITIONS THEY ARE EXPOSED TO. THIS PURCHASE IS FOR BATTERY PACKS TO SUPPORT EXISTING STATIONS IN CO-OPS’ NETWORK OF ENVIRONMENTAL MONITORING STATIONS. SIGNIFICANT ENGINEERING EFFORT WAS UTILIZED TO ENSURE ALL INTERIOR COMPONENTS FIT IN THE SPACE AVAILABLE AND ARE OF APPROPRIATE MATERIALS AND QUALITY AND ARE ELECTRICALLY COMPATIBLE WITH THE GAUGES THEY ARE TO BE INTEGRATED INTO. IMPLEMENTING DIFFERENT COMPONENTS WILL RESULT IN ADDITIONAL COST AND RESOURCES. ALSO, THERE WILL BE RESULTING DELAY FOR TESTING, TRAINING, AND PURCHASE OF SUPPORT EQUIPMENT.


UNDER THE CURRENT CO-OPS OPERATING SYSTEM ANY ENVIRONMENTAL MONITORING EQUIPMENT THAT HAS NOT PREVIOUSLY BEEN APPROVED MUST BE SUBJECTED TO A SERIES OF TESTS TO ENSURE THE QUALITY OF THE DATA AND THE DURABILITY OF THE EQUIPMENT FOR THE INTENDED USE. THESE TESTS USUALLY INCLUDE BENCH TESTING USING CONTROLLED CONDITIONS AND PHYSICAL MEASUREMENT, CONTROLLED ENVIRONMENTAL TESTING TO CHECK THE EQUIPMENT’S RELIABILITY UNDER DIFFERENT CONDITIONS, AND LONG-TERM COMPARISON TESTING WITH ACCEPTED EQUIPMENT AT MULTIPLE REAL-WORLD LOCATIONS. THESE TESTS AND THE ANALYSIS OF THE RESULTING DATA TAKE A LARGE AMOUNT OF TIME, MONEY, AND RESOURCES TO CONDUCT.


CURRENTLY CO-OPS FIELD PERSONAL AND CONTRACTORS ARE TRAINED IN THE USE AND MAINTENANCE OF THE ITEMS IN THIS PURCHASE. ADDITIONAL COST WILL INCUR FROM HAVING TO TRAIN FIELD PERSONAL AND CONTRACTORS ON THE USE AND MAINTENANCE OF NEW EQUIPMENT. CO-OPS ALSO HAS THE ABILITY AND EQUIPMENT TO TEST AND MONITOR THE EQUIPMENT IN THIS PURCHASE. IF NEW EQUIPMENT IS PURCHASED ADDITIONAL PARTS AND EQUIPMENT WILL NEED TO BE PURCHASED TO SUPPORT THE NEW EQUIPMENT.


DELIVERY DATE: 115 DAYS FROM DATE OF AWARD.


***THIS PRESOLICITATION NOTICE IS NOT A REQUEST FOR COMPETITIVE PROPOSALS AND NO SOLICITATION PACKAGE IS AVAILABLE. HOWEVER, FIRMS THAT BELIEVE THEY CAN FULLY MEET THE GOVERNMENT'S REQUIREMENTS MAY SUBMIT SUBSTANTIATING DOCUMENTATION OR A REQUEST FOR ADDITIONAL INFORMATION IN WRITING TO THE IDENTIFIED POINT OF CONTACT WITHIN 15 DAYS AFTER PUBLICATION OF THIS PRE-SOLICITATION NOTICE. SUCH REQUESTS AND DOCUMENTATION WILL BE EVALUATED SOLELY FOR THE PURPOSE OF DETERMINING WHETHER OR NOT TO CONDUCT THIS PROCUREMENT ON A COMPETITIVE BASIS. A DETERMINATION BY THE GOVERNMENT NOT TO CONDUCT A COMPETITIVE PROCUREMENT, BASED UPON RESPONSES TO THIS NOTICE, IS SOLELY WITHIN THE DISCRETION OF THE GOVERNMENT. ORAL COMMUNICATIONS ARE NOT ACCEPTABLE IN RESPONSE TO THIS NOTICE

Similar Contracts

Same NAICS industry code

More opportunities from Department Of Commerce Noaa

Same awarding agency

NAICS: 325120
New
Federal
68--Helium supplied to NWS Salt Lake City, UTHelium gas will be supplied incrementally to the National Weather Service Weather Forecast Office in Salt Lake City, Utah, under a combined synopsis/solicitation issued as a request for quotation, with a fixed-price contract subject to economic price adjustment expected to result. The requirement calls for approximately 47,260 cubic feet of helium to be delivered in roughly equal increments every three weeks from July 27, 2026, through April 30, 2027, using standard 291 CF cylinders, with up to 163 cylinders total and an option to increase cylinder quantity by up to 64, along with up to 14 deliveries and an option to add six more. Cylinder rentals are allowed with a maximum of 18 cylinders on-site at any time for up to 278 days. Delivery is FOB destination at the Upper Air Inflation Building on-site, and all deliveries must be coordinated to meet the schedule without option extensions. The acquisition is a total small business set-aside under NAICS code 325120 with a 1,200-employee size standard and includes a class waiver for the nonmanufacturer rule, with no limitations on subcontracting. Quotations must be submitted via email to Jen Brown by 10:00 a.m. MDT on Friday, July 23, 2026, with the solicitation number in the subject line, and must include pricing for helium per cylinder, delivery fees, hazmat fees, and cylinder rental rates. The government will evaluate offers on a best-value basis without regard to Free Trade Agreements, and award is anticipated for July 24, 2026.
Industrial Gas Manufacturing

POSTED

1 day ago

DEADLINE

in 2 days
View Details
NAICS: 236220
New
Federal
Z--Constructions Services for Staging Space RenovatioThe solicitation for commercial construction services to renovate the Lab Row Staging Space at the NOAA Western Regional Center in Seattle, Washington, is issued as a firm-fixed-price, total small business set-aside under NAICS code 236220 with solicitation number 1305M326Q0271. The contract requires the contractor to provide all labor, equipment, and materials necessary for renovations in rooms 1074 through 1077, encompassing demolition, architectural, mechanical, electrical, plumbing, HVAC, and fire protection systems, while excluding sprinkler relocations, card reader access systems, diffusers, fire alarms, and low voltage work. The work includes installing open shelving and utility tables per designated drawings, modifying walls with drywall and paint, filling wall and floor openings, adding blocking for casework, and ensuring a one-hour fire rating in corridor wall cavities. Performance must comply with the Statement of Work and all applicable specifications, with the base period of performance lasting one year after issuance of the notice to proceed and no option periods available. All quotations must be submitted electronically by 12:00 PM MDT on August 5, 2026, to Jamie.Rosales@noaa.gov in PDF or Microsoft Word format, accompanied by signed SF-18 and SF-30 forms, UEID and CAGE CODE, and an active SAM registration. A mandatory Asbestos-Containing Materials Certification is required as a pass/fail gate, and failure to include it will result in rejection. Evaluation is based on a trade-off process where technical approach, experience in building restoration, and past performance in responsiveness, quality, and customer service are significantly more important than price, although price will be assessed for completeness and reasonableness. Contractors must have all personnel as U.S. citizens or legal immigrants, submit security forms to the COR, adhere to strict facility access and identification protocols, and ensure safeguarding of government property. A pre-construction conference is required with the project manager, superintendent, SSHO, QCM, and major subcontractors present. Performance and payment bonds are required under FAR 52.228-15, and construction materials must comply with Buy American requirements. Monthly invoices must be submitted through the IPP system to the COR, with payment terms net 30, and final inspections require ten days' notice and sign-off from the Site QC Manager. All work is subject to government inspection at any time,
Commercial and Institutional Building Construction

POSTED

1 day ago

DEADLINE

in 14 days
View Details