B040 Elevator Repair Project

Closed
SLAC_263718RFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 333921
Federal
Sources Sought Notice for On-Site Elevator Maintenance Service for Wagner IHS Healthcare Center
Solicitation # IHS-WAG-27-1532090
The Indian Health Service is conducting market research via Sources Sought Notice IHS-WAG-27-1532090 to identify qualified small businesses and Indian Economic Enterprises for a non-personal, firm-fixed-price service contract. The objective is to secure on-site maintenance, inspection, and repair services for one direct plunger hydraulic elevator at the Wagner Health Center in Wagner, South Dakota. The scope of work includes routine servicing, annual inspections in accordance with ASME A17.2-2023, and ensuring the elevator's integration with fire detection and emergency power systems remains functional. The anticipated period of performance consists of a base year from January 1, 2027, to December 31, 2027, with four subsequent one-year option periods extending through December 31, 2031. The contract will be managed by a Level 1 Contracting Officer's Representative and a Facility Manager, with a strong emphasis on 100 percent compliance for safety-critical requirements and certifications. Contractors must adhere to NFPA 101 Life Safety Codes and maintain strict data privacy standards in compliance with HIPAA and the Privacy Act of 1974. Administrative requirements include monthly electronic invoicing via the Invoice Processing Platform per HHSAR 352.232-71 and the maintenance of detailed service logs. This notice is for planning purposes under NAICS code 333921 and does not constitute a formal solicitation; interested parties must submit their capabilities to the designated purchasing agent by October 31, 2026.
Great Plains Area Indian Health Svc

POSTED

14 days ago

DEADLINE

in 1 day

General Info

Agency

N/A

NAICS

333921 - Elevator and Moving Stairway Manufacturing

Place of Performance

2575 Sand Hill Road, MENLO PARK, CA, 94025, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
Contacts1 person available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
Contacts

Full Description

Show more
Provide repair work to for necessary modernization upgrades to the existing hydraulic elevator manufactured by Independent Elevator Co. and installed in the north wing of B040 at SLAC National Accelerator Laboratory. The existing elevator in B040 is a hydraulic passenger elevator originally installed in 1964, with 2,500 lbs. capacity, 3 stops and a speed of 75 F.P.M. The existing B040 elevator was installed with a single bottom hydraulic cylinder unit which has an inherent risk of failure at the bottom of the cylinder which can cause the elevator to fall to the ground catastrophically. To mitigate this risk SLAC is seeking a qualified elevator subcontractor to replace the existing single bottom hydraulic cylinder, piston, buffers and supports at the elevator in B040 with a new double bulkhead hydraulic cylinder, piston, buffer and support The selected subcontractor shall be responsible for a design-build upgrade project to remove and replace the single bottom hydraulic cylinder, piston, buffers, and supports. Subcontractor shall incorporate the performance specifications included in this RFP as part of the basis of design for the new double bulkhead hydraulic cylinder retrofit package. Subcontractor shall include a delivery schedule as part of their proposal; include shop drawings preparation time, review and approval time (allow 10 working days for SLAC review time), long lead equipment shall be included in schedule as part of the subcontractor's proposal as well as installation, start-up, testing and commissioning. Subcontractor shall field verify all existing conditions before submitting a final proposal to SLAC. This posting is for sources sought purposes only. Any pricing information provide will be discarded and the provider will be removed from any further consideration.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS