Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on August 15, 2008. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Backflow Prevention

Closed
W91ZRS-08-T-0013Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

332913 - Plumbing Fixture Fitting and Trim Manufacturing

Place of Performance

103 Airlift Wing Connecticut Air National Guard 100 Nicholson Road, EAST GRANBY, CT, 060269309, USA

Set-Aside

SBA

Documents

1

W91ZRS-08-T-0013 Backflow Prevention Device Solicitation

DOC, High priority: read this firstrfq
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W7MZ Uspfo Activity Ctang 103
Contacts2 people available
OfficeEAST GRANBY, CT, 06026-9309, USA
Office AddressEAST GRANBY, CT, 06026-9309, USA
Contacts
Dawn.WhelanBase Contracting Officer
Piper L. MassePurchasing Agent

Full Description

Show more
STATEMENT OF WORK ACQUIRE & INSTALL, BACKFLOW PREVENTION DEVICES IN VARIOUS BUILDINGS BRADLEY AIR NATIONAL GUARD BASE & ORANGE AIR NATIONAL GUARD STATION PROJECT NUMBER: CEKT08106 11 August 2008 BACKGROUND: The objective of a Backflow Prevention or Cross Connection Control Program is to prevent the introduction of pollutants or contaminants into the drinking water distribution system. Air Force Instruction (AFI) 32-1066, Plumbing Systems, along with federal, state and local requirements, establish backflow prevention requirements for Air Force installations. LOCATION: Various buildings located at Bradley ANG 100 Nicholson Road, East Granby, CT 06026 & Orange ANG Station, 206 Boston Post Road, Orange, CT 06477 ADMINISTRATION: References: 1. Connecticut Air National Guard Comprehensive Drinking Water Cross-Connection And Backflow Prevention Survey Report 2. AFI 32-1066 Contacts: For access or technical information: Capt Krzysztof Kucharski +1 (555) 000-0000 For contracting information: TSgt Dawn Whelan +1 (555) 000-0000 SCOPE: Acquire and install: 1) Nine (9) - testable backflow prevention assembly (BFPAs) on unprotected systems 2) Fourteen (14) - untestable backflow prevention devices (BFP) on unprotected systems PERIOD OF PERFORMANCE The total contractor time for this task order shall not exceed 15 days. DELIVERABLES Acquire and install: Five (5) - 2" bronze backflow prevention devices (reduced - pressure principle assembly) Three (3) - 1.25" bronze backflow prevention devices (atmospheric vacuum breaker) One (1) - 1" bronze backflow prevention device (reduced - pressure principle assembly) One (1) - 1" bronze backflow prevention device (air gap) One (1) - 0.75" bronze backflow prevention device (reduced - pressure principle assembly) Two (2) - 0.75" bronze backflow prevention devices (atmospheric vacuum breaker) One (1) - 0.75" bronze backflow prevention device (hose bib vacuum breaker) Two (2) - 0.50" bronze backflow prevention devices (reduced - pressure principle assembly) Four (4) - 0.50" bronze backflow prevention devices (atmospheric vacuum breaker) One (1) - 0.50" bronze backflow prevention device (dual check valve with intermediate atmospheric vent) One (1) - 0.375" bronze backflow prevention device (atmospheric vacuum breaker) One (1) - 0.25" bronze backflow prevention device (dual check valve with intermediate atmospheric vent) END

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS