Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

BCCA Compliant Material Supplier

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Place of Performance

San Diego, CA, 92037, USA

Set-Aside

NONE

Documents

This scope was carved out of 20261028022.

The full solicitation package (2 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

5735 East Campus Utility Plant Chiller #5

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyThe Regents of the University of California
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Supplies BCCA-compliant eligible materials for prime contractors on University of California, San Diego (UCSD) utility plant projects. Provides carbon steel rebar, structural steel, flat glass, and mineral wool board insulation. Supplies facility-specific Type III (ISO 14025) Environmental Product Declarations (EPD) to demonstrate compliance with Buy Clean California Act standards. Delivers certified materials and EPD documentation.

Similar Contracts

Same NAICS industry code

More opportunities from The Regents of the University of California

Same awarding agency

NAICS: 236220
New
SLED
5735 East Campus Utility Plant Chiller #5
Solicitation # 20261028022
The Regents of the University of California are soliciting bids for the installation of one 1,600-ton water cooled chiller, designated as Chiller 6, at the East Campus Utility Plant in San Diego, California. The scope of work includes the installation of the chiller along with upgrades to primary chilled water and condenser water pumps, piping, controls, power, and anchorage. Additional requirements encompass electrical upgrades to substation 1A/1B and potential alternate upgrades to substation 2A/2B, as well as demolition, infrastructure, landscaping, fire protection, mechanical, and plumbing systems. This project is critical for the day one operations of the Outpatient Pavilion. The project is divided into two phases, with Phase 1 requiring completion within 120 days and Phase 2 within 183 days of their respective notices to proceed. Award selection is based on Best Value, evaluating a combination of price and qualifications through a scored package and a Best Value Questionnaire. Bidders must submit a single PDF via the e-Builder Bidding Module by 4:00 P.M. on November 12, 2026, including a bid bond for 10 percent of the anticipated contract amount. Contractors must adhere to strict quality control and packaging standards, including the use of original packaging and specific exterior storage requirements. The contract requires performance and payment bonds, certificates of insurance, and compliance with prevailing wage rates and Cal/OSHA safety orders. Furthermore, the University emphasizes the participation of Small Business Enterprises and Disabled Veteran Business Enterprises. Final acceptance of the work requires certification from the Design Professional of Record and successful completion of all fire, life, and safety tests.
Commercial and Institutional Building Construction

POSTED

about 8 hours ago

DEADLINE

in 14 days
View Details
NAICS: 236220
New
SLED
UWVMC 2nd Floor Sterilizer Replacement
Solicitation # 40293-CP1576
Solicitation 40293-CP1576 is a project for the University of California, Los Angeles (UCLA) to replace the 2nd Floor STERRAD 100NX sterilizer equipment. The scope of work includes equipment anchorage and the installation of a new electrical power and data port junction wall box. Due to the clean and sanitized nature of the environment, the contractor must implement Infection Prevention Level 5 standards using 6-mil plastic or heavier barriers to mitigate dust. All project work is restricted to night shifts only. The contract will be awarded to the lowest responsive and responsible bidder, with a response deadline of November 17, 2026. The project is located in Los Angeles, California, and requires adherence to California State General Prevailing Wage Determination 2026-2. Bidders must submit their proposals in a sealed opaque envelope using the official Bid Form, accompanied by a notarized Bid Bond. Post-award requirements include providing three originals of the Payment and Performance Bonds, certificates of insurance, and a preliminary contract schedule. The University will provide builder's risk property insurance if the final contract sum exceeds 300,000 dollars. Payment is processed via itemized monthly applications for payment submitted by the 10th of each month, supported by cost breakdowns and certified payrolls. The University also encourages the participation of Small Business Enterprises and Disabled Veteran Business Enterprises.
Commercial and Institutional Building Construction

POSTED

6 days ago

DEADLINE

in 19 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel