C--DESIGN STEAM HEADER REPAIRS Canandaigua VAMC

Awarded
VA24217R0955Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541330
New
International
Pump Optimisation and Aeration Efficiency Analysis
Solicitation # FA2253
Thames Water Utilities Limited is establishing a single-lot, sole-supplier framework agreement under solicitation FA2253 for pump optimisation and aeration efficiency services. The contract focuses on the monitoring, testing, and analysis of pumping and aeration systems across approximately 60 operational sites, encompassing roughly 200 tests during the AMP period. The primary objective is to reduce whole-life costs and improve operational performance through a structured delivery model that includes site identification, efficiency studies, and performance monitoring. The agreement will feature fixed pricing structures based on an agreed rate card and will be managed through key performance indicators to ensure strategic partnership and continuous improvement. The contract is scheduled for an initial three-year term starting May 10, 2027, with potential extensions up to a maximum of eight years, ending May 9, 2035. Eligible suppliers must demonstrate a proven track record of delivering measurable savings and innovation and must have the capacity to operate within London, the Thames Valley, and the Home Counties. Award selection is based on a 50% technical and 50% commercial weighting. The procurement process is a multi-stage procedure requiring a Pre-Selection Questionnaire via SAP Ariba by October 19, 2026, followed by an Invitation to Negotiate stage. Successful providers must also meet stringent insurance requirements, including 15 million pounds for public and products liability and 10 million pounds for professional indemnity.
Thames Water Utilities Limited

POSTED

about 2 hours ago

DEADLINE

N/A

AI Contract Overview

Show more

The VA Medical Center in Canandaigua, New York, is seeking a Service Disabled Veteran Owned Small Business (SDVOSB) for the design of steam header and vacuum system condensate return repairs. The project involves investigating system deficiencies, specifically regarding inadequate condensate return to Building 12 and design flaws in Building 5. The selected architect-engineer firm will be responsible for reviewing system load, capacity, and routing, and providing a complete construction package including plans and specifications to restore the system to sustainable working order. This procurement is set aside for SDVOSBs under NAICS code 541330, with an estimated construction cost between 250,000 and 500,000 dollars. Selection is based on a short-list process evaluating SF330 submissions, focusing on professional qualifications, specialized technical competence, past performance with government agencies, and the firm's capacity to complete the work within the required timeframe. Eligible firms must be located within a 400 mile radius of the facility.

General Info

Contract Value

$35,544

NAICS

541330 - Engineering Services

Place of Performance

NY, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Sources Sought

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)
ContactsNo contacts available
OfficeALBANY, NY, 12208, USA
Office AddressALBANY, NY, 12208, USA
ContactsNo contact information available

Full Description

Show more
General The VA Medical Center, Canandaigua, New York is engaging in a short-list selection as defined in FAR 36.602-5(a) of an AE (SDVOSB) for the design of a project titled: Design Steam Header Repair. SDVOSB Firms with an SF330 on file within the past twelve (12) months and within a 400 mile radius to the Canandaigua VAMC are being considered. If you believe you have an SF330 on file and would like to be considered for this procurement please send an e-mail to contact@example.gov expressing your interest in being considered. If your firm does not have an SF330 on file, or you wish to update previously submitted SF330 s, please do so by emailing the Contract Specialist at contact@example.gov by 4:00 PM EST, August 31, 2017. This project will include but is not limited to the following: Investigate inadequate vacuum system condensate return to Building 12 and design deficiency in Building 5. Review system load, capacity, routing and configuration, pipe diameter, vacuum pumps, ancillary equipment and components. Provide full design and provide complete construction package plans and specifications for repair and necessary modification to the vacuum system condensate return at the VA Medical Center at 400 Fort Hill Avenue, Canandaigua NY 14424. AE Scope of Work for the South Feed Condensate Return Repair Generally the scope of AE work is to provide thorough investigation for mechanical steam system and low pressure (Vacuum) condensate return. Perform engineering and design for a complete execution package which contain plans and specifications for contractor solicitation. The A/E shall prepare from the investigative findings, a recommendation of repair/replace, component/system to return the system to proper and sustainable working order. This will include a written report of component/system deficiency s and failures. Existing Conditions: The vacuum system was installed to return low pressure condensate to the Boiler Plant (Building 12) from Buildings 1, 2, 3, 4, 5, 9, 33 and 34. Currently portions of the system are disabled. The Building 9 return valve is closed and Building 1 low pressure return is now released to sewer. Both conditions are due to capacity and flow constraints believed attributed loss of vacuum, maintenance, end of useful life and other causes. The low pressure system has been intermittently and incompletely modified and appears to now perform as an inefficient gravity return system. Routing design difficulties resulted in a low trap section being installed at Building 5 which further restrain the condensate return and exacerbate maintenance issues. Two B-12 vacuum pumps with receiver tank connected to the low pressure return system have performance issues. One pump draws +- 3 vacuum when the intake valve is closed. No vacuum is drawn when the valve is opened to the overall system. The other pump is out of service. High pressure condensate is also returned to Building 12 via a gravity system in buildings serviced by the vacuum system as well as other buildings at the Medical Center. Performance appears to be satisfactory. A full scope of services will be included in the formal solicitation after a review of the SF330s The following evaluation criteria will be used when reviewing submitted SF330 data and will comprise the basis of information to be used by Canandaigua VAMC for A/E evaluation and selection. Firms submitting SF330 data for consideration must address each of the following criteria in the SF330: SHORT-LIST CRITERIA UTILIZING THE SF330 FORM Department of Veterans Affairs Architect/Engineer Evaluation Board Professional qualifications necessary for satisfactory performance of required services. Specialized experience and technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. Capacity to accomplish the work in the required time. Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules Location in the general geographical area of the project and knowledge of the locality of the project; provided, that application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the project Reputation and standing of the firm and its principal officials with respect to professional performance, general management, and cooperativeness. Record of significant claims against the firm because of improper or incomplete architectural and engineering services. Specific experience and qualifications of personnel proposed for assignment to the project and their record of working together as a team. Discussions may be held with the top ranking firms. These discussions will at a minimum include a verification of accuracy of the information within the SF330 and a chance to provide any updated information. Responses to discussion items will be evaluated using the same factors outlined above. This procurement is set-aside for Service Disabled Veteran Owned Small Businesses (SDVOSB). The estimated construction cost for this project is between $250,000 and $500,000. The NAICS code for this procurement is 541330 (Engineering Services). The small business size standard for NAICS 541330 is currently $15 million.

More opportunities from Department Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)

Same awarding agency

NAICS: 238290
New
Federal
J039--561A4-25-500 Elevator Repair Building 6 and 53
Solicitation # 36C24226R0097
Solicitation 36C24226R0097 is a Request for Proposal issued by the Department of Veterans Affairs for the emergency upgrade and modernization of four elevators at the VA New Jersey Healthcare System Lyons Campus, specifically targeting one passenger elevator in Building 6 and one service and two passenger elevators in Building 53. The scope of work requires the contractor to provide all labor, materials, and supervision to install non-proprietary microprocessor-based control systems, new geared machines, car operating panels with braille markings, hall fixtures at ADA compliant heights, and complete shaft wiring. All work must adhere to current safety codes, including fire recall features and door lock monitoring, and comply with the Davis-Bacon Act for prevailing wage rates. This procurement is a Service-Disabled Veteran-Owned Small Business set-aside under NAICS code 238290. To be eligible, the prime contractor must be a licensed elevator maintenance company with a full-time mechanic on staff and a clean safety record, certifying no more than three serious, one repeat, or one willful OSHA or EPA violation in the last three years. Proposals are evaluated based on technical capability, past performance, and price, with a requirement to submit a current Experience Modification Rate (EMR) and certifications for the Buy American Act and limitations on subcontracting. Following several extensions to accommodate requests for information, the final deadline for proposal submission is 1:00 PM on Thursday, October 29, 2026.
Other Building Equipment Contractors

POSTED

about 5 hours ago

DEADLINE

in 22 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS